DOI QR코드

DOI QR Code

Failure Mode Effective Analysis for selection of Single Point Vulnerability in New type Nuclear Power Plant

신규노형 원전의 발전정지유발기기 선정을 위한 고장모드영향분석

  • Received : 2014.05.09
  • Accepted : 2014.05.23
  • Published : 2014.07.01

Abstract

For decreasing an unexpected shutdown of Nuclear Power Plants, Korea Hydro & Nuclear Power co.(KHNP) has developed Single Point Vulnerability(SPV) of NPPs since 2008. SPV is the equipment that cause reactor shutdown & turbine trip or more than 50% power rundown due to its malfunction. New type Nuclear Power Plants need to develop the SPV list, so performed the SPV selection for about 1 year. To develop this, Failure Mode Effect Analysis(FMEA) methods are used. As results of FMEA analysis, about 700 equipment are selected as SPV. Thereafter those are going to be applied to new type Nuclear Power Plants to enhance equipment reliability.

Keywords