Studies have shown that the thermal performance of buildings changes depending on the year of construction completion. It leads to increased energy consumption of buildings and significant financial burden on users. Thus, this study has calculated the thermal insulation performance of 86 apartments quantitatively, using temperature difference ratio and sensible heat flux. Also, energy consumption characteristics depending on the year of construction completion and thermal insulation performance were analyzed by comparatively analyzing the results of insulation performance evaluation and heating costs. The analysis results are as follows. As for thermal insulation performance, it was around 70% lower in the apartments completed before 1985, compared to apartments completed after 2010. As for heating costs, the apartments with the highest heating cost incurred 1.5 higher heating cost than the apartment with the lowest heating cost. In terms of the insulation performance evaluation, the difference was 2.5-fold.

Keywords

References

  1. Akira Hoyano, Kohichi Asano, Takehisa Kanamaru, Analysis of the sensible heat flux from the exterior surface of buildings using time sequential thermography, Atmospheric Environment 33; 1999, p. 3941-3951 https://doi.org/10.1016/S1352-2310(99)00136-3
  2. Lee, Tae-Cheol, Yoon, Seong-Hwan, Review on Radiation Temperature Distribution of a Multipurpose High-rise Building by Infrared Rays Camera, Journal of the Korean Institute of Architectural Sustainable Environment and Building Systems; 2012, p. 77-80
  3. Park, Jung-Hun, Kim, Bong-Joo, Comparative Performance Evaluation by Winter Apartment Temperature on the Outer Surface of the Insulation, Journal of the Korea Institute for Structural Maintenance and Inspection; Vol. 17, No. 4, 2013, p. 91-100 https://doi.org/10.11112/jksmi.2013.17.4.091
  4. Choi, Gyoung-Seok, Jeong, Young-Sun, Kang, Jae-Sik, Lee, Seung-Eon, Developemnt of In-site Evaluation Method for Building Insulation Performance Using Infra-red Camera, Journal of Architectural Institute of Korea; Vol. 24, No. 1, 2004, p. 762-765
  5. Kim, Kyeong-A, Kim, Bong-Joo, Heat Loss the Case Study of Office Building, Academic Journal of the Korea Institute of Building Construction; Vol. 11, No. 1, 2011, p. 51-54 https://doi.org/10.5345/JKIC.2011.02.1.051
  6. Hong, In-Pyo, Lee, Su-Mi, Jung, Eun-Young, Song, Doo-Sam, A Study on the Propriety of Wind Profile in CFD Simulation for predicting Wind Environment of Urban Area, Journal of the Korean Institute of Architectural Sustainable Environment and Building Systems, Vol. 2011, No. 3, 2011, p. 97-100

Cited by

  1. Appropriate conditions for determining the temperature difference ratio via infrared camera vol.37, pp.3, 2016, https://doi.org/10.1177/0143624415600701