A Correlation Analysis between the Airtightness and Sound Insulation Performance on the Opening Spaces of Han-style Windows

한식 창호의 개구 면적에 따른 기밀 및 차음 성능간 상관성 연구

  • Lee, Ju-Yeob (Industrial Technology Research Institute, Chonnam National University) ;
  • Jang, Hyeon-Chung (Dept. of Architecture, Graduate School, Chonnam National University) ;
  • Lee, Tai-Gang (Industrial Technology Research Institute, Chonnam National University) ;
  • Song, Min-Jeong (Industrial Technology Research Institute, Chonnam National University) ;
  • Kim, Sun-Woo (Dept. of Architecture, Chonnam National University)
  • Received : 2014.04.21
  • Accepted : 2014.06.23
  • Published : 2014.06.30

Abstract

The purpose of this study is to evaluate the correlation coefficients between the airtightness and sound insulation performance of Han-style windows in New Han-ok. To achieve these goals, field measurements were accomplished in 18 bedrooms of 16 Han-oks in which actual residents were living, and then lab measurements were proceeded in the reverberation lab for evaluating the sound insulation performance. Followings are results. The results of the correlation analysis between the airtightness(Air change per hour at 50 Pa, ACH50) and sound insulation performance(Sound reduction index, Rw) in bedrooms of actual Han-oks, it was found that there were no significant correlation between two evaluating values. On the other hand, it was analyzed that the correlation coefficients of total 24 structures(double casement windows, single casement window, casement and sliding windows, single sliding window, 6 types per each structure) were located on 0.6757 exponentially and 0.4154 lineary in the lab evaluating conditions. But, The results of evaluating 4 structure classificatorily, it was found that there were high correlation coefficients(0.8665~0.9273 at ACH50, 0.8414~0.9346 at Rw). These results were signified that the correlation coefficients were changed according to the each structure and case by case analysis were necessary at the same time.

Keywords

References

  1. Lee, J., Song, M., Lee, T., Kim, S(2012), An Experimental Study on Evaluation of the Sound Insulation for Han-ok composition elements, Proceedings of the Korean society for Noise and Vibration Engineering, vol.2012, No.2, pp.409-410.
  2. Lee, J., Jang, H., Song, M., Lee, T., Kim, S(2013), A Study on the Airtightness and Sound Insulation Performance of New Han-ok Bedrooms, Journal of the Korea Institute of Ecological Architecture and Environment, Vol.13 No.3, pp.79-89.
  3. Park, C., Hong, G., Choi, J., Lee, Y., Choi, J(2013), A study on the Correlation between Airtightness and Sound Insulation in the Apartment Housing, Proceedings of the Korean society for Noise and Vibration Engineering, vol.2013, No.2, pp.296-297
  4. Park, H(2012), Evaluation of Airborne Sound Insulation Performance of Airtightness Improved Window, Proceedings of the Korean Housing Association, Vol.32, No.2, pp.357-358.
  5. Kim, S., Lee, T., Kim, H., Kim, H, Choi, E(2006), An Experimental Study on the Sound Insulation Performance of Korean Traditional Houses, Journal of the Korea Institute of Ecological Architecture and Environment, Vol.16, No.2, pp.141-148. https://doi.org/10.5050/KSNVN.2006.16.2.141
  6. KIm, M., Kim, H(2004), An Experimental Study on the Evaluation of the Sound Insulation ofr Balcony Window in Apartment Houses, Journal of the Korea Institute of Ecological Architecture and Environment, Vol.14, No.11, pp.1137-1146 https://doi.org/10.5050/KSNVN.2004.14.11.1137
  7. Korean agency for Technology and Standard(2006), KS L ISO 9972:2006 Thermal Insulation - Determination of Building Airtightness-Fan Pressurization method
  8. Korean agency for Technology and Standard(2001), KS F 2235:2001 Field Measurements of Sound Insulation of Building Facades and Facade Elements.
  9. Korean agency for Technology and Standard(2011), KS F 2808:2001 Laboratory Measurements of Airborne Sound Insulation of Building Elements.
  10. Korean agency for Technology and Standard(2002), KS F 2862:2002 Rating of airborne sound Insulation in Buildings and of Building Elements.
  11. ISO 9972(2006) Thermal Performance od Buildings - Determination of air permeability of buildings - Fan pressurization method.
  12. The Energy Conservatory(2010), Minneapolis Blower Door Operation Manual for Model 3 and Model 4 Systems. The Energy Conservatory.
  13. ASTM E 779:10 Standard Test Method for Determining Air Leakage Rate by Fan Pressurization
  14. ASHRAE Standard 119-1988, Air Leakage Performance for Detached Single Family Residential Buildings, 1998(Withdrawn Standard(Updated February 2013), Withdrawn 2/17/2012, Standard 119 requirements were placed in Std 62.2)
  15. ANSI/ASHRAE Standard 62.2-2004, Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings, American Society of Heating Refrigerating and Air Conditioning, Engineers, Inc., Atlanta, GA.
  16. CGSB Standard 149.15(1996), Determination of the overall enveloped air-tightness of buildings by the fan pressurization method using the building's air handling system, Canadian General Standards Board.

Cited by

  1. Comparative Evaluation on the Airborne sound Insulation Performance of Modern New Han-oks according to the Field Measurements vol.20, pp.5, 2014, https://doi.org/10.12813/kieae.2020.20.5.115
  2. Carbon absorption capability of single-leaf and compound-leaf plants in the BNI Urban Forest, Banda Aceh vol.918, pp.1, 2021, https://doi.org/10.1088/1755-1315/918/1/012027