DOI QR코드

DOI QR Code

Enhancing Robustness of Floor Vibration Control by Using Asymmetric Tuned Mass Damper

비대칭 동조질량감쇠기를 활용한 바닥진동제어의 강건성 향상 방안

  • Ko, A Ra (SNU, Building Works Engineering Team) ;
  • Lee, Cheol Ho (Dept. of Architecture and Architectural Engineering, Seoul National University) ;
  • Kim, Sung Yong (Dept. of Architecture and Architectural Engineering, Seoul National University)
  • Received : 2013.11.01
  • Accepted : 2014.05.22
  • Published : 2014.06.27

Abstract

When floor vibration problems occur in existing buildings, TMD (tuned mass damper) can be a viable alternative to resolving the problem. Only when TMD has been exactly tuned to the natural frequency of the floor, it can control the vibration as intended in design. However, TMD gets inefficient in the situation where the natural frequency changes as a result of the uncontrollable variation of the floor mass weight. This physical phenomenon is often called as TMD-off-tuning. This study proposes asymmetric TMD for enhancing the robustness of floor vibration control against uncertain natural frequencies. The proposed TMD features two asymmetric linear springs such that the floor vibrational energy can be dissipated through both the translational and rotational motion. An easy-to-use graphical optimization method was developed in this study. The asymmetric TMD proposed outperformed in vibration control by 28% compared to that of conventional TMD. The robustness of asymmetric TMD of this study was two times higher than that of conventional TMD.

최근 강재의 고강도화를 통한 부재 단면 사이즈의 절감은 종종 강성의 부족으로 이어져 과도한 처짐이나 진동문제를 야기한다. 따라서 적절한 설계나 예방을 통해 구조물의 바닥진동에 대한 보완이 필수적이다. 이러한 바닥진동 문제를 해결하기 위해 동조질량감쇠기가 종종 쓰이고 있다. 동조질량감쇠기는 바닥의 진동수에 대해 정확히 설계되었을 때에는 효율적으로 바닥진동을 제어할 수 있다. 하지만 바닥질량의 크기와 외부하중의 특성에 따라 바닥의 진동수가 수시로 변하는 경우에는 그 효율이 급격히 낮아질 가능성이 있다. 이러한 현상을 동조이탈이라고 한다. 본 연구는 실제 바닥에 가해지는 하중의 변화에 따라 바닥의 진동수가 달라지는 양상을 실험을 통해 고찰한다. 실험 바닥에 기존의 단일동조질량감쇠기를 적용하여 단일동조질량 감쇠기의 한계인 동조이탈현상을 확인한다. 또한, 바닥진동제어의 강건성을 확보하기 위해 진동수의 불확실성을 반영한 비대칭 동조질량감쇠기의 활용을 제안한다. TMD의 강건성이란 진동수가 변화하는 상황에서 바닥진동제어 성능이 얼마나 지속되느냐를 뜻한다. 제안된 비대칭 TMD는 두 개의 비대칭 강성을 가지고 있기 때문에 병진운동과 회전운동을 하면서 진동에너지를 소산한다. 제안된 비대칭TMD의 최적화 결과, 비대칭TMD는 기존 STMD에 비해 28%이상의 진동제어성능을 확보하였으며, 외부의 환경 변화에 대한 강건성은 약 1.4배 개선되었다.

Keywords

References

  1. Frahm, H. (1911) Vibrations of Bodies, U.S. Patent No.989,958.
  2. Warburton, G.B. (1982) Optimum Absorber Parameters for Various Combinations of Response and Excitation parameters, Earthquake Engineering & Structural Dynamics, Vol.10, No.3, pp.381-401. https://doi.org/10.1002/eqe.4290100304
  3. 김기두, 황윤국, 변윤주, 장동일(1997) 난류하에서의 TMD에 의한 현수교 주탑의 진동제어, 한국강구조학회논문집, 한국강구조학회, 제9권, 제2호, pp.181-191. Kim, K.D., Hwang, Y.K., Byun, Y.J., and Chang, D.I. (1997) Vibration Control for Tower of Suspension Bridge Under Turbulance Using TMD, Journal of Korean Society of Steel Construction, KSSC, Vol.9, No.2, pp.181-191 (in Korean).
  4. 김주명, 이규원(2004) 동조질량감쇠기를 이용한 해양구조물의 진동제어, 한국강구조학회 논문집, 한국강구조학회, 제16권, 제1호, pp.73-79. Kim, J.M. and Lee, G.W. (2004) Vibration Control of Offshore Platform using Tuned Mass Damper, Journal of Korean Society of Steel Construction, KSSC, Vol.16, No.1, pp.73-79 (in Korean).
  5. Minjuan, H., Renle, M., and Zhao, L. (2007) Design of Structural Vibration Control of a Tall Steel TV Tower under Wind Load, International Journal of Steel Structures, KSSC, Vol.7, No.1, pp.85-92.
  6. Zuo, L. and Nayfeh, S. (2004) Minimax Optimization of Multi-Degree-of-Freedom Tuned-Mass Damper, Journal of Sound and Vibration, ELSEVIER, Vol.272, No.3-5, pp.893-908. https://doi.org/10.1016/S0022-460X(03)00500-5
  7. Li, C.X. and Qu, W.L. (2006) Optimum Properties of Multiple Tuned Mass Dampers for Reduction of Translational and Torsional Response of Structures Subject to Ground Acceleration, Engineering Structures, ELSEVIER, Vol.28, No.4, pp.472-494. https://doi.org/10.1016/j.engstruct.2005.09.003
  8. Lenzen, K.H. (1966) Vibration of Steel Joist-Concrete Slab Floors, AISC Eng. J., Vol.3, No.3, pp.133-136.
  9. Setareh, M., et al. (2006) Pendulum Tuned Mass Dampers for Floor Vibration Control, Journal of performance of constructed facilities, Vol.20, No.1, pp.64-73. https://doi.org/10.1061/(ASCE)0887-3828(2006)20:1(64)
  10. Zuo, L. and Nayfeh, S.A. (2006) The Two-Degreeof-Freedom Tuned-Mass Damper for Suppression of Single-Mode Vibration under Random and Harmonic Excitation, Journal of vibration and acoustics, Vol. 128, pp.56-65. https://doi.org/10.1115/1.2128639
  11. Steel Construction Institute (2007) Design of Floors for Vibration: A New Approach, SCI P354, Berkshire.
  12. 대한건축학회(2009) 건축구조설계기준 및 해설(KBC 2009), 기문당. AIK (2009) Korean Building Code and Commentary - Structural, Architectural Institute of Korea (in Korean)
  13. Ellis, B. R. (1997) Human-Structure Interaction in Vertical Vibrations, Structures and Buildings, Vol.122, No.1, pp.1-9. https://doi.org/10.1680/istbu.1997.29162
  14. American Institute of Steel Construction (1997) Steel Design Guide 11 - Floor Vibrations Due to Human Activity, AISC, USA.
  15. CSI(2004) Analysis Reference Manual for SAP2000, ETABS, and SAFE, Computers and Structures, Inc., California, USA.