This study aims at examining kinetic efficient shading systems and their implementation methods. These days, the importance of the shading devices are getting more significant due to the energy problem. Cordially, suitable shade designs are required as an important element for the exterior envelope of the building. This study employs the optimal shading design as an efficient shading method with the kinetic system that can be converted actively by the altitude of the sun. The proposed kinetic shading system works not only as a lightshelf in case the altitude of the sun is high but also as a vertical louver when the sun is getting lower in order to block the direct sunlight. This study has analyzed the thermal performance and shading coefficient of the kinetic shading system in comparison to existing fixed shading devices using the Ecotect. The results, in sum, conclude that the suggested kinetic shading system could decrease direct sunlights 26.2% more than the existing shading methods.

Keywords

References

  1. Ko, Dong-Hwan, Assessment and Analysis of Green Building Performances Using Autodesk ECOTECT Analysis 2010, Magazine of the Architectural Institute of Korea, v.29, n.9, pp.13-21, 2011.
  2. Kim, Deuk-Woo, Park, Cheol-Soo, Needs and Issues for Better Use of Building Energy Simulation Tools at Design Stage, Journal of the Architectural Institute of Korea, v.28, n.10, pp.317-325, 2012.
  3. Kim, Min-Seok, Yim, Hae-Lee, Kim, Ju-Hyung, Kim, Jae-Jun, An Evaluation of Interior Illuminance in the Indoor Room to Different Louver Type and Distance, Proceeding of Annual Conference of Korean Society of CAD/CAM Engineers, v.2012, n.2, pp.141-146, 2012.
  4. Kim, Sang-Bum, Park, Jong-Hoon, Yang, Byoung-E, A Study on Glazing Ratio of Certified Green Building Apartment, Journal of Korea Institute of Ecological Architecture and Environment, v.10, n.5, pp.95-100, 2010.
  5. Kim, Yoon Jeong, Kim, Jeong Tai, Comparative Daylighting Performance of a Classroom with Traditional and Louver type Shading Devices, Journal of Korea Institute of Ecological Architecture and Environment, v.13, n.4, pp.21-26, 2013. https://doi.org/10.12813/kieae.2013.13.4.021
  6. Kim, Han-Yong, Kim, Kang-Soo, A Study on Daylighting Performance Evaluation for the Green Building Certification and Daylight Prediction According to Design Elements, Journal of the Architectural Institute of Korea, v.29, n.7, pp.239-246, 2013.
  7. Park, Yoon-Young, A Study on the Proper Shade Design for Reducing Glare in General Classrooms for Schools, Master's Thesis, Kwangwoon University, 2009.
  8. Bae, Tae-Goan, Jeon, Young-Il, The Shading Performance of External Shading Devices in the Office Building with Glazed Facade Ratio of 75%, Proceeding of Annual Conference of the Architectural Institute of Korea, v.31, n.1, pp.187-188, 2011.
  9. Baek, Sang-Hoon, A Fundamental Study on the Optimal Design of Folding Shading Device, Master's Thesis, Inha University, 2008.
  10. Jeong, In Young, Choi, Yoon Seok, Ahn, Hyun-Tae, Kim, Jeong Tai, Visual Comfort Evaluation of Interior Spaces by Daylighting Systems, Journal of Korea Institute of Ecological Architecture and Environment, v.6, n.1, pp.17-24, 2006.
  11. Cho, Jin-Kyun, Yoo, Chang-Woo, A Feasibility Study and Energy Analysis of Exterior Shading Device on Cooling Energy Demand for High-rise Residences, Journal of the Architectural Institute of Korea, v.26, n.12, pp.303-311, 2010.
  12. Choi, Jaepil, Lee, Tae-Kyoung, Ahn, Eui-Soon, Piao, Gen-Song, Lim, Jang-Hyun, An Evaluation System for Parametric Exterior Louver Designs Including Physical Surroundings, Journal of the Architectural Institute of Korea, v.29, n.10, pp.91-98, 2012.
  13. U.S. Depertment of Energy, http://apps1.eere.energy.gov/