DOI QR코드

DOI QR Code

Evaluation of Thermal and Visual Environment for the Glazing and Shading Device in an Office Building with Installed of Venetian Blind

베네시안 블라인드가 적용된 오피스 건물의 외피 투과체 계획을 위한 열·빛 환경 평가에 대한 연구

  • Kim, Chul-Ho (Department of Architecture, Graduate School, Korea University) ;
  • Kim, Kang-Soo (Department of Architecture, Korea University)
  • Received : 2015.09.14
  • Accepted : 2015.11.04
  • Published : 2015.12.31

Abstract

Purpose: Glazing and shading devices influence a lot on the thermal and visual environment in office buildings. Solar heat and daylight are contrary concept, therefore proper arrangement of thermal and optical performance is needed when designing a glazing and shading devices. The purpose of this study is to examine the conditions of the glazing and shading devices available for promoting the reduction of cooling loads + lighting loads and the improvement in thermal comfort and visual comfort for the summer season in an office building installed with venetian blind. Method: This study established 12 simulation cases which have different glazings and the positions of venetian blind for evaluating different thermal and optical performance. And by using EnergyPlus v8.1 and Window v7.2 program, we quantitatively analyzed cooling loads + lighting loads, thermal comfort and visual comfort in an office building installed with the glazing and shading devices. Result: Consequently, Case 9(Double Low-E+Exterior Blind) is the best arrangement of solar heat gain and daylight influx, thereby becomes the most excellent case of reducing cooling+lighting loads(46.8%) and simultaneously becomes the enhancement case in thermal comfort. Also, DGI(Daylight glare index) under clear sky conditions in summer was evaluated to be 19.6, and thereby satisfied the recommendation level of allowing visual comfort.

Keywords

References

  1. 김철호, 양자강, 김강수, "투과체 성능과 베네시안 블라인드 설치 위치에 따른 냉방부하 절감과 열쾌적 향상 방안에 관한 연구", 대한건축학회 학술발표대회 논문집, Vol.35 No.1, 2015.04 // (Kim, Chul-Ho, Yang, Ja-Kang, Kim, Kang-Soo, Effect of glazing types and venetian blind position on cooling loads and thermal comfort, 2015 Spring Annual Conference, Architectural Institute of Korea, 2015.04)
  2. 이소연, 김강수, "주거건물용 이중외피 시스템의 블라인드 조절에 따른 에너지 성능평가에 관한 연구", 한국태양에너지학회, Vol.30 No.6, 2010.12 // (Lee, So-Yeun, Kang, Jae-Sik, Kim, Kang-Soo, Energy performance evaluation of a double-skin facade with a venetian blind in residential buildings, Journal of the Korean Solar Energy Society, 2010.12)
  3. Nopparat Khamporn, Somsak Chaiyapinunt, Effect of installing a venetian blind to a glass window on human thermal comfort, Building and Environment, 2014(82), 713-725 https://doi.org/10.1016/j.buildenv.2014.10.022
  4. Kyle Konis, Evaluation daylighting effectiveness and occupant visual comfort in a side-lit open-plan office building in San Francisco, California, Building and Environment, 2013(59), 662-677 https://doi.org/10.1016/j.buildenv.2012.09.017
  5. Astrid Roetzel, Aris Tsangrassoulis, Udo Dietrich, Impact of building design and occupancy on office comfort and energy performance in different climates, Building and Environment, 2014(71), 165-175 https://doi.org/10.1016/j.buildenv.2013.10.001
  6. F.Stazia, S.Marinellia, Di Pernab, P.Munafoa, Comparison on solar shadings: Monitoring of the thermo-physical behaviour, assessment of the energy saving, thermal comfort, natural lighting and environmental impact, Solar Energy, 2014(105), 512-528 https://doi.org/10.1016/j.solener.2014.04.005
  7. Atmaca I, Kaynakli O, Yigit A, Effects of radiant temperature on thermal comfort, Building and Environment, 2007;42(9):3210-3220 https://doi.org/10.1016/j.buildenv.2006.08.009
  8. DOE, EnergyPlus v8.1 Engineering Reference (The Reference to EnergyPlus Calculation), US Department of Energy, 2013
  9. ISO 7730, Ergonomics of the thermal environment -Analytical determination and interpretation of the thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria, ISO, 2005
  10. Association Suisse des Electriciens Schweizerischer Elekrtrotechnischer Verein (SEV) http://www.sev.ch/f
  11. A.Tzempelikos, A.K.Athienitis, The impact of shading design and control on building cooling and lighting demand, Solar Energy, 2007;81(3): 369-382 https://doi.org/10.1016/j.solener.2006.06.015
  12. Azza Nabil, John Mardaljevic, Useful daylight illuminances: A replacement for daylight factors, Energy and Buildings, 2006;7(38)
  13. Hopkinson R.G., Glare from daylighting in buildings, Applied Ergonomics, 1972;3(1), 206-215 https://doi.org/10.1016/0003-6870(72)90102-0
  14. Robert H. Henninger, Michael J. Witte, EnergyPlus Testing with Building Thermal Envelope and Fabric Load Tests from ANSI, ASHRAE Standard 140-2011, Arlington, USA, 2013
  15. 한국표준협회, "조도기준", KS A 3011:1998 // (Korea Standards Association, Recommended levels of illumination, KS A 3011:1998)
  16. ASHRAE, ASHRAE Handbook Standard 90.1 Section 13, Energy standard for buildings except low-rise residential buildings
  17. 한국건설기술연구원, 한국에너지기술연구원, "건물의 에너지효율등급 평가기준 및 정책개발에 관한 연구", 2007 // (KICT(Korea Institute of Civil Engineering and Building Technology), KIER(Korea Institute of Energy Research), The study of the development of energy performance assessment method and policy in buildings, Ministry of Trade, Industry and Energy, 2007)
  18. 국토교통부, 에너지관리공단, "건축물의 에너지절약 설계기준 해설서 2015 (국토교통부 고시 제 2014-957호)", // (KEMCO(Korea Energy Management Corporation), Building energy saving design standards 2015)
  19. P.G.Loutzenhisera, H.Manza, Felsmannc, P.A.Strachand, T.Franka, G.M.Maxwell, Empirical validations of solar gain models for a glazing unit with exterior and interior blind assemblies, Energy and Buildings, 2008;40(3):330-340 https://doi.org/10.1016/j.enbuild.2007.02.034
  20. M.Bessoudo, A.Tzempelikos, A.K.Athienitis, R.Zmeureanu, Indoor thermal environmental conditions near glazed facades with shading devices-Part I: Experiments and building thermal model, Building and Environment, 2010;45(11):2506-2516 https://doi.org/10.1016/j.buildenv.2010.05.013
  21. Eric Shen, Jia Hu, Maulin Patel, Energy and visual comfort analysis of lighting and daylight control strategies, Building and Environment, 2014(78), 155-170 https://doi.org/10.1016/j.buildenv.2014.04.028

Cited by

  1. Solar Heat Gain Coefficient Analysis of a Slim-Type Double Skin Window System: Using an Experimental and a Simulation Method vol.11, pp.1, 2018, https://doi.org/10.3390/en11010115
  2. Analysis of Energy Saving Potential in High-Performance Building Technologies under Korean Climatic Conditions vol.11, pp.4, 2018, https://doi.org/10.3390/en11040884
  3. Development of Sky Luminance and Daylight Illuminance Prediction Methods for Lighting Energy Saving in Office Buildings vol.12, pp.4, 2019, https://doi.org/10.3390/en12040592
  4. Detailed Comparison of the Operational Characteristics of Energy-Conserving HVAC Systems during the Cooling Season vol.12, pp.21, 2019, https://doi.org/10.3390/en12214160
  5. Development of Kinetic Skin for Energy Saving of User-Based Buildings vol.20, pp.1, 2015, https://doi.org/10.12813/kieae.2020.20.1.103