DOI QR코드

DOI QR Code

Experimental Determination of Closed Cup Flash Point of Binary Flammable Solutions, 2-Propanol+Propionic acid and n-Hexanol+Formic Acid Solutions

가연성 이성분계 용액인 2-Propanol+Propionic acid 와 n-Hexanol+Formic acid 용액의 밀폐식 인화점의 실험적 결정

  • Ha, Dong-Myeong (Dept. of Occupational Health and Safety Engineering, Semyung University) ;
  • Lee, Sungjin (Dept. of Clinical Laboratory Science, Semyung University)
  • 하동명 (세명대학교 보건안전공학과) ;
  • 이성진 (세명대학교 임상병리학과)
  • Received : 2015.03.19
  • Accepted : 2015.06.05
  • Published : 2015.06.28

Abstract

The flash point is one of the most important indicators of the flammabiliy of liquid solutions. The flash point is the lowest temperature at which there is enough concentration of flammable vapor to form an ignitable mixture with air. In this study the flash points of binary flammable solutions, 2-propanol+propionic acid and n-hexanol+formic acid systems, were measured using Seta flash closed cup tester. Particularly n-hexanol+formic acid system exhibited minimum flash point behavior. The measured values were compared with the calculated values using Raoult's law and optimization method. The calculated data by optimization method described the measured values more effectively than those calculated by Raoult's law.

인화점은 액체 용액의 가장 중요한 인화성 지표 중 하나이다. 인화점은, 가연성 증기의 공기 속 농도가 점화가 발생하기에 충분할 때의 온도 중 가장 낮은 온도이다. 본 연구에서는 가연성 이성분계 액체 용액인, 2-propanol+propionic acid 와 n-hexanol+formic acid 계의 인화점을 Seta flash 밀폐식 장치를 사용하여 측정하였다. 특히 n-hexanol+formic acid 계는 최소 인화점 현상을 보였다. 측정값은 라울의 법칙을 활용한 방법과 최적화 기법에 의한 계산값과 비교되었다. 그 결과 최적화 기법에 의한 계산값이 라울의 법칙에 의한 계산값 보다 측정값을 잘 모사하였다.

Keywords

References

  1. Pan, Y., Cheng, J., Song, X., Li, G., Ding, L., and Jiang, J., "Flash points measurements and prediction for bunary miscible mixtures", J. of Loss Prevention in the Process Industries, 34, 56-64, (2015) https://doi.org/10.1016/j.jlp.2015.01.022
  2. Liaw, H.J., Gerbaud V., and Li, Y.H., "Prediction of Miscible Mixtures Flash-Point from UNIFAC Group Contribution Methods", Fluid Phase Equilibria, 300, 70-82, (2011) https://doi.org/10.1016/j.fluid.2010.10.007
  3. Kong, D., am Ende, D.J., Brenek, S.J., and Weston, N.P., "Determination of Flash Point in Air and Pure Oxygen Using an Equilibrium Closed Bomb Apparatus", J. of Hazardous Materials, A102, 155-165, (2003)
  4. Moghadam, A.Z., Rafiei, A., and Khalili, T., "Assessing Prediction Models on Calculating the Flash Point of Organic Acid, Ketone and Alcohol Mixtures", Fluid Phase Equilibria, 316, 117-121, (2012) https://doi.org/10.1016/j.fluid.2011.12.014
  5. Phoon, L.Y., Mustaffa, A.A., Hashim, H., and Mat, R., "A Review of Flash Point Prediction Models for Flammable Liquid Mixtures", Ind. Eng. Chem. Res., 53, 12523-12565, (2014)
  6. Hshieh, F.Y., "Note : Correlation of Closed- Cup Flash Points with Normal Boiling Points for Silicone and General Organic Compounds", Fire and Materials, 21, 277-282, (1997) https://doi.org/10.1002/(SICI)1099-1018(199711/12)21:6<277::AID-FAM617>3.0.CO;2-3
  7. Whckey, R., and Chittenden, D., "Flash Points of Blend Correlated", Hydrocarbon Process, 42(6), 157-158, (1963)
  8. Catoire, L., and Naudet, V.A., "A Unique Equation to Estimate Flash Points of Selected Pure Liquids Application to the Correction of Probably Erroneous Flash Point Values", J. Phys. Chem. Ref. Data, 33(4), 1083-1112, (2004) https://doi.org/10.1063/1.1835321
  9. Affens, W.A. and Mclaren, G.W., "Flammability Properties of Hydrocarbon Solutions in Air", J. of Chem. & Eng. Data, 17(4), 482-488, (1972) https://doi.org/10.1021/je60055a040
  10. Le Chatelier, "Esimation of Firedamp by Flammability limits", Ann. Minmes, 19, 388-392, (1891)
  11. Ha, D.M. and Lee, S.J., "The Measurement and Prediction of the Flash Points for the Water+2-Propanol System Using Open-Cup Apparatus", Fire Science and Engineering, 21(2), 48-53, (2007)
  12. Reid, C.R., Prausnitz, J.M., and Poling, B.E., The Properties of Gases and Liquids, 4th Edition., McGraw-Hill, New York, (1998)
  13. Liaw, H.J., Chen, C.T., Cheng, C.C., and Yang, Y.T., "A Mathematical Model for Predicting the Flash Point of Binary Solution", J. of Loss Prevention in the Process Industries, 15, 429-438, (2002) https://doi.org/10.1016/S0950-4230(02)00068-2
  14. Liaw, H.J., Tang, C.L., and Lai, J.S., "A Model for Predicting the Flash Point of Ternary Flammable Solutions of Liquid", Combust Flame, 138, 308-319, (2004) https://doi.org/10.1016/j.combustflame.2004.06.002
  15. Gmehing, J., Onken, U., and Arlt, W., Vapor- Liquid Equilibrium Data Collection, 1, Part1-Part7, DECHEMA, (1980)
  16. Wilson, G.M., "Vapor Liquid Equilibrium. XI A New Expression for the Excess Free Energy of Mixing", J. of the American Chemical Society, 86, 127-130, (1994)
  17. Abrams, D.S., and Prausnitz, J.M., "Statistical Thermodynamics of Liquid Mixtures : New Expression for the Excess Gibbs Energy of Partly of Completely Miscible Systems", AICHE Journal, 21, 116-128, (1975) https://doi.org/10.1002/aic.690210115
  18. Kuester, J.L., and Mize, J.H., "Optimization Techniques with Fortran", McGraw-Hill, New York, (1973)
  19. Ha, D.M., and Lee, S.J., "The Flash Point Measurement for Binary Flammable Mixture", KIGAS, 18(5), 60-65, (2014)
  20. American Society for Testing Materials, Annual Book of ASTM Standards, Vol. 06.01, (1999)