DOI QR코드

DOI QR Code

무구속적 방법으로 측정된 심전도의 신뢰도 판별

Quality Level Classification of ECG Measured using Non-Constraint Approach

  • 김윤재 (서울대학교 대학원 협동과정 바이오엔지니어링 전공) ;
  • 허정 (서울대학교 대학원 협동과정 바이오엔지니어링 전공) ;
  • 박광석 (서울대학교 의과대학 의학과 의공학교실) ;
  • 김성완 (서울대학교 의과대학 의학과 의공학교실)
  • Kim, Y.J. (Interdisciplinary Program for Bioengineering, Graduate School, Seoul National University) ;
  • Heo, J. (Interdisciplinary Program for Bioengineering, Graduate School, Seoul National University) ;
  • Park, K.S. (Department of Biomedical Engineering, Seoul National University College of Medicine) ;
  • Kim, S. (Department of Biomedical Engineering, Seoul National University College of Medicine)
  • 투고 : 2016.08.05
  • 심사 : 2016.10.20
  • 발행 : 2016.10.31

초록

Recent technological advances in sensor fabrication and bio-signal processing enabled non-constraint and non-intrusive measurement of human bio-signals. Especially, non-constraint measurement of ECG makes it available to estimate various human health parameters such as heart rate. Additionally, non-constraint ECG measurement of wheelchair user provides real-time health parameter information for emergency response. For accurate emergency response with low false alarm rate, it is necessary to discriminate quality levels of ECG measured using non-constraint approach. Health parameters acquired from low quality ECG results in inaccurate information. Thus, in this study, a machine learning based approach for three-class classification of ECG quality level is suggested. Three sensors are embedded in the back seat, chest belt, and handle of automatic wheelchair. For the two sensors embedded in back seat and chest belt, capacitively coupled electrodes were used. The accuracy of quality level classification was estimated using Monte Carlo cross validation. The proposed approach demonstrated accuracy of 94.01%, 95.57%, and 96.94% for each channel of three sensors. Furthermore, the implemented algorithm enables classification of user posture by detection of contacted electrodes. The accuracy for posture estimation was 94.57%. The proposed algorithm will contribute to non-constraint and robust estimation of health parameter of wheelchair users.

키워드

참고문헌

  1. K. Krauchi and A. Wirz-Justice, "Circadian clues to sleep onset mechanisms", Neuropsychopharmacology, vol. 25, no. S5, pp. S92-S96, 2001. https://doi.org/10.1016/S0893-133X(01)00315-3
  2. S.Y. Sim, K.M. Joo, H.B. Kim, S.J. Jang, B.O. Kim, S.B. Hong, S. Kim, and K.S. Park, "Estimation of circadian body temperature rhythm based on heart rate in healthy, ambulatory subjects, IEEE J. Biomed. Health Inform.", In press.
  3. Y.J. Kim, H. Jeong, K.S. Park, and S. Kim, "Proposition of novel classification approach and features for improved real-time arrhythmia monitoring", Comput. Biol. Med., vol. 75, pp. 190-202, 2016. https://doi.org/10.1016/j.compbiomed.2016.06.009
  4. M.G. Tsipouras and D.I. Fotiadis, "Automatic arrhythmia detection based on time and time-frequency analysis of heart rate variability", Comput. Methods Prog. Biomed., vol. 74, no. 2, pp. 95-108, 2004. https://doi.org/10.1016/S0169-2607(03)00079-8
  5. L.A. Geddes, M.H. Voelz, C.F. Babbs, J.D. Bourland, and W.A. Tracker, "Pulse Transit Time as an Indicator of Arterial Blood Pressure", Psychophysiology, vol. 18, no. 1, pp. 71-74, 1981. https://doi.org/10.1111/j.1469-8986.1981.tb01545.x
  6. R. McCraty, M. Atkinson, W.A. Tiller, G. Rein, and A.D. Watkins, "The effects of emotions on short-term power spectrum analysis of heart rate variability", Am. J. Cardiol., vol. 76, no. 14, pp. 1089-1093, 1995. https://doi.org/10.1016/S0002-9149(99)80309-9
  7. M.T. La Rovere, J.T. Bigger Jr, F.I. Marcus, A. Mortara, and P.J. Schwartz, "Baroreflex sensitivity and heart-rate variability in prediction of total cardiac mortality after myocardial infarction", The Lancet, vol. 351, no. 9101, pp. 478-484, 1998. https://doi.org/10.1016/S0140-6736(97)11144-8
  8. W.K. Lee, H.J. Lee, H.N. Yoon, G.S. Chung, and K.S. Park, "Automatic Noise Removal and Peak Detection Algorithm for ECG measurement from Capacitively Coupled Electrodes Included within a Cloth Mattress Pad", J. Biomed. Eng. Res., vol. 35, no. 4, pp. 87-94, 2014. https://doi.org/10.9718/JBER.2014.35.4.87
  9. J.S. Lee, W.K. Lee, Y.G. Lim, and K.S. Park, "Adhesive Polyurethane-based Capacitive Electrode for Patch-type Wearable Electrocardiogram Measurement System", J. Biomed. Eng. Res., vol. 35, no. 6, pp. 203-210, 2014. https://doi.org/10.9718/JBER.2014.35.6.203
  10. J.S. Paul, M.R. Reddy, and V.J. Kumar, "A Transform Domain SVD Filter for Suppression of Muscle Noise Arte-facts in Exercise ECG's", IEEE Trans. Biomed. Eng., vol. 47, no. 5, pp. 654-663, 2000. https://doi.org/10.1109/10.841337
  11. J.L. Talmon, J.A. Kors, and J.H.V. Bemmel, "Adaptive Gaussian Filtering in Routine ECG/VCG Analysis", IEEE Trans. Sig. Process., vol. ASSP-34, no. 3, pp. 527-534, 1986.
  12. N.V. Thakor, and V.S. Zhu, "Applications of Adaptive Filtering to ECG Analysis: Noise Cancellation and Arrhythmia Detection", IEEE Trans. Biomed. Eng., vol. 38, no. 8, pp. 785-794, 1991. https://doi.org/10.1109/10.83591
  13. C. Vaz, X. Kong, and N. Thakor, "An Adaptive Estimation of Periodic Signals Using a Fourier Linear Combiner", IEEE Trans. Biomed. Eng., vol. 42, no.1, pp. 1-10, 1994.
  14. J.O. Wisbeck, and R.G. Ojeda, "Application of Neural Networks to Separate Interferences and ECG Signals", In: Proceedings of IEEE international Caracas conference on devices, circuits and systems, pp. 291-294, 1998.
  15. Q. Li, C. Rajagopalan, and G.D. Clifford, "A machine learning approach to multi-level ECG signal quality classification", Comput. Methods Programs Biomed., vol. 117, no. 3, pp. 435-447, 2014. https://doi.org/10.1016/j.cmpb.2014.09.002
  16. G.D. Clifford, J. Behar, Q. Li, and I. Rezek, "Signal quality indices and data fusion for determining clinical acceptability of electrocardiograms", Physiol. Meas., vol. 33, no. 9, pp. 1419-1433, 2012. https://doi.org/10.1088/0967-3334/33/9/1419
  17. J. Behar, J. Oster, Q. Li, and G.D. Clifford, "ECG Signal Quality During Arrhythmia and Its Application to False Alarm Reduction", IEEE Trans. Biomed. Eng., vol. 60, no. 6, pp. 1660-1666, 2013. https://doi.org/10.1109/TBME.2013.2240452
  18. Y.G. Lim, J.S. Lee, S.M. Lee, H.J. Lee, and K.S. Park, "Capacitive Measurement of ECG for Ubiquitous Healthcare", Ann. Biomed. Eng., vol. 42, no.11, pp. 2218-2227, 2014. https://doi.org/10.1007/s10439-014-1069-6
  19. J.S. Lee, "Adhesive Polyurethane-based Capacitive Electrode for Patch-type Wearable Electrocardiogram Measurement System", J. Biomed. Eng. Res., vol. 35, no. 6, pp. 203-210, 2014. https://doi.org/10.9718/JBER.2014.35.6.203