DOI QR코드

DOI QR Code

Software Development for Dynamic Positron Emission Tomography : Dynamic Image Analysis (DIA) Tool

동적 양전자방출단층 영상 분석을 위한 소프트웨어 개발: DIA Tool

  • Pyeon, Do-Yeong (Department of Health Science, Dongseo University) ;
  • Kim, Jung-Su (Department of Radilogical Science, Dongnam Health University) ;
  • Jung, Young-Jin (Department of Health Science, Dongseo University)
  • 편도영 (동서대학교 보건과학과) ;
  • 김정수 (동남보건대학교 방사선학과) ;
  • 정영진 (동서대학교 보건과학과)
  • Received : 2016.07.19
  • Accepted : 2016.09.10
  • Published : 2016.09.30

Abstract

Positron Emission Tomography(PET) is nuclear medical tests which is a combination of several compounds with a radioactive isotope that can be injected into body to quantitatively measure the metabolic rate (in the body). Especially, Phenomena that increase (sing) glucose metabolism in cancer tissue using the $^{18}F$-FDG (Fluorodeoxyglucose) is utilized widely in cancer diagnosis. And then, Numerous studies have been reported that incidence seems high availability even in the modern diagnosis of dementia and Parkinson's (disease) in brain disease. When using a dynamic PET iamge including the time information in the static information that is provided for the diagnosis many can increase the accuracy of diagnosis. For this reason, clinical researchers getting great attention but, it is the lack of tools to conduct research. And, it interfered complex mathematical algorithm and programming skills for activation of research. In this study, in order to easy to use and enable research dPET, we developed the software based graphic user interface(GUI). In the future, by many clinical researcher using DIA-Tool is expected to be of great help to dPET research.

양전자방출단영상(Positron Emission Tomography, PET)은 여러 화합물과 방사성 동위원소를 결합하여 인체 내에 주입하여 인체 내의 대사율을 정량적으로 측정할 수 있는 핵의학적 검사이다. 특히, 암 조직에서 포도당 대사가 증가되는 현상을 $^{18}F$-FDG(Fluorodeoxyglucose)를 사용하여 널리 암 진단에 활용하며, 현대에서 발병 빈도가 높은 뇌질환 중 치매 및 파킨슨 진단에도 높은 유용성을 보인다는 연구가 다수 진행되었다. 이러한 현재의 정적 정보에 시간의 동적 정보를 포함하는 동적 양전자방출단층영상(dynamic PET, dPET)을 이용할 경우, 진단을 위한 추가적인 정보가 제공되므로 진단의 정확도 향상에 기여할 수 있다. 이러한 이유로 임상 연구자 및 방사선사의 큰 관심을 받고 있으나 연구를 진행하기 위해 손쉽게 사용 가능한 도구가 부족한 실정이며, 다양하고 복잡한 수학적 알고리즘(algorithm)이나 프로그래밍(programming) 기술이 부족할 경우 연구의 활성화를 방해하는 높은 진입장벽으로 존재하게 되므로, 본 연구에서는 dPET 연구의 활성화와 손쉬운 사용을 위해서 MATLAB을 이용하여 그래픽 유저(GUI) 기반으로 하여 무료 소프트웨어를 개발하였으며, 개발된 소프트웨어인 DIA-Tool(Dynamic Image analysis-Tool)은 복잡한 수학적 영상 분석 알고리즘을 누구나 손쉽게 사용할 수 있도록 설계되었다. 향후, 많은 임상 연구자들이 DIA-Tool을 이용하여 국내의 dPET 연구 발전에 큰 도움이 될 것이라 기대된다.

Keywords

References

  1. Kitagawa. Y, Nishizawa. S, and Sano. K, "Prospective Comparison of 18 F-FDG PET with Conventional Imaging Modalities (MRI, CT, and 67 Ga Scintigraphy) in Assessment of Combined Intraarterial Chemotherapy and Radiotherapy for Head and Neck Carcinoma," vol. 44, no. 2, pp. 198-207, 2003
  2. Piert. M, Koeppe. Ra, Giordani. B, Minoshima. B, and Kuhl. D. E, "Determination of regional rate constants from dynamic FDG-PET studies in Parkinson's disease.," J. Nucl. Med., vol. 37, no. 7, pp. 1115-1122, 1996
  3. Tomasi. G, Turkheimer. F, and Aboagye. E, "Importance of quantification for the analysis of PET data in oncology: Review of current methods and trends for the future," Mol. Imaging Biol., vol. 14, no. 2, pp. 131-136, 2012 https://doi.org/10.1007/s11307-011-0514-2
  4. Wernick. M. N, Infusino. E. J, and Milosevic. M, "Fast spatio-temporal image reconstruction for dynamic PET.," IEEE Trans. Med. Imaging, vol. 18, no. 3, pp. 185-195, 1999 https://doi.org/10.1109/42.764885
  5. Kumar. R. P, Senthil. T, "3D Reconstruction Of Facial Structures From 2D Images For Cosmetic Surgery," IEEE-International Conf. Recent Trends Inf. Technol., vol. 67, pp. 1049-1054, 2011
  6. Li. H. H and Votaw. J. R, "Optimization of PET activation studies based on the SNR measured in the 3-D Hoffman brain phantom.," IEEE Trans. Med. Imaging, vol. 17, no. 4, pp. 596-605, 1998 https://doi.org/10.1109/42.730404
  7. Paschalis. S, Lee. I. Y, MacChiavelli. A. O, Campbell. C. M, Cromaz. M, Gros. S, Pavan. J, Qian. J, Clark. R. M, Crawford. H. L, Doering. D, Fallon. P, Lionberger. C, Loew. T, Petri. M, Stezelberger. T, Zimmermann. S, Radford. D. C, Lagergren. K, Weisshaar. D, Winkler. R, Glasmacher. T, Anderson. J. T, and Beausang. C. W, "The performance of the Gamma-Ray Energy Tracking In-beam Nuclear Array GRETINA," Nucl. Instruments Methods Phys. Res. Sect. A Accel. Spectrometers, Detect. Assoc. Equip., vol. 709, pp. 44-55, 2013
  8. Jagust. W. J, Seab. J. P, Huesman. R. H, Valk. P. E, Mathis. C. a, Reed. B. R, Coxson. P. G, and Budinger. T. F, "Diminished glucose transport in Alzheimer's disease: dynamic PET studies.," J. Cereb. Blood Flow Metab., vol. 11, no. 2, pp. 323-30, 1991 https://doi.org/10.1038/jcbfm.1991.65
  9. Perez-Medina. C, Tang. J, Abdel-Atti. D, Hogstad. B, Merad. M, Fisher. E. a, Fayad. Z. a, Lewis. J. S, Mulder. W. J. M, and Reiner. T, "PET Imaging of Tumor-Associated Macrophages with 89Zr-Labeled High-Density Lipoprotein Nanoparticles.," J. Nucl. Med., vol. 56, no. 8, pp. 1272-7, 2015 https://doi.org/10.2967/jnumed.115.158956
  10. Do-Yeong. P, Jung-Su. K, Cheol-Ha. B, Young-Jin. J, "Singular Value Decomposition based Noise Reduction Technique for Dynamic PET Image : Preliminary Study" J. ksrs. vol. 39, no. 2, pp. 227-236, 2016.