DOI QR코드

DOI QR Code

A Study on Evaluation Criteria for Infrastructure Importance regarding Earthquake

공공시설물 지진대응을 위한 중요도 평가기준에 관한 연구

  • Park, Jae-woo (Construction Policy Institute, Korea Institute of Civil Engineering and Building Technology) ;
  • Kim, Seok (Dept. of Railroad Infrastructure System Engineering, Korea National University of Transportation)
  • 박재우 (한국건설기술연구원, 건설정책연구소) ;
  • 김석 (한국교통대학교 철도인프라시스템공학과)
  • Received : 2018.10.29
  • Accepted : 2018.12.03
  • Published : 2018.12.31

Abstract

The perception of earthquake in Korea has changed due to the earthquake that occurred in Gyeongju and Pohang, and the earthquake has become an important factor in infrastructure management. Damage to infrastructures in the event of an earthquake is extensive. In particular, damage to infrastructures that perform public function used to spread to the whole area. From the point of view of earthquake disaster prevention, it is very important for the public to define what infrastructures are important management targets and to prepare a countermeasure. In this study, we propose a method to evaluate the importance of infrastructure to effectively manage infrastructures for earthquakes. For this purpose, important factors for the railway bridges, power generation and electric power facilities, and apartment complexes are suggested. AHP analysis is conducted to suggest priorities. In addition, the evaluation criteria for infrastructure importance are presented.

Keywords

SOOOB6_2018_v21n6_317_f0001.png 이미지

Fig. 1 Importance Evaluation Factors: Railroad

SOOOB6_2018_v21n6_317_f0002.png 이미지

Fig. 2 Importance Evaluation Factors: Power Generation

SOOOB6_2018_v21n6_317_f0003.png 이미지

Fig. 3 Importance Evaluation Factors: Apartment

Table 1. Evaluated facilities

SOOOB6_2018_v21n6_317_t0001.png 이미지

Table 2. Pairwise comparison scale between two alternatives

SOOOB6_2018_v21n6_317_t0002.png 이미지

Table 3. Subject characteristics in the survey

SOOOB6_2018_v21n6_317_t0003.png 이미지

Table 4. AHP analysis result of importance factor(Railroad)

SOOOB6_2018_v21n6_317_t0004.png 이미지

Table 5. AHP analysis result of importance factor(Power generation)

SOOOB6_2018_v21n6_317_t0005.png 이미지

Table 6. AHP analysis result of importance factor(Apartment)

SOOOB6_2018_v21n6_317_t0006.png 이미지

Table 7. Evaluation score of seismic design (Railroad bridge)

SOOOB6_2018_v21n6_317_t0007.png 이미지

Table 8. Evaluation score of main bridge length (Railroad bridge)

SOOOB6_2018_v21n6_317_t0008.png 이미지

Table 9. Rating of railroad track

SOOOB6_2018_v21n6_317_t0009.png 이미지

Table 10. Evaluation score of design speed (Railroad bridge)

SOOOB6_2018_v21n6_317_t0010.png 이미지

Table 11. Evaluation score of seismic design (Power generation)

SOOOB6_2018_v21n6_317_t0011.png 이미지

Table 12. Evaluation score of location (Power generation)

SOOOB6_2018_v21n6_317_t0012.png 이미지

Table 13. Evaluation score of degradation (Power generation)

SOOOB6_2018_v21n6_317_t0013.png 이미지

Table 14. Evaluation score of seismic design (Apartment)

SOOOB6_2018_v21n6_317_t0014.png 이미지

Table 15. Evaluation score of structural material (Apartment)

SOOOB6_2018_v21n6_317_t0015.png 이미지

Table 16. Evaluation score of height (Apartment)

SOOOB6_2018_v21n6_317_t0016.png 이미지

Table 17. Evaluation method and score range by priority

SOOOB6_2018_v21n6_317_t0017.png 이미지

References

  1. H.I. Lee, "Social Trend in Korea" pp 268-278, (2017).
  2. Ministry of Public Administration and Security, "2016 Announcement of Results of Promotion of seismic retrofit measures for existing public facilities", (2017).
  3. E.Y. Shin, J.W. Park, K.S. Lee, "A study on Criticality Criteria of National Facilities", Korea Facility Security Corporation, pp.12-18, (2010).
  4. J.W. Park, M.J. Chae, G. Lee, M.Y. Cho, "Test-bed Development for Long-term Monitoring of Small Bridge Asset Management", Journal of Korea Institute of Construction Engineering and Management, vol.13, no.6, pp.13-23, (2012). https://doi.org/10.6106/KJCEM.2012.13.6.013
  5. J.W. Park, S. Kim, "Development of Importance Evaluation System for National Major Infrastructures using AHP Method" Journal of Korea Contents Association, vol.15, no.8, pp 532-543, (2015). https://doi.org/10.5392/JKCA.2015.15.08.532
  6. Earthquake Engineering Society of Korea, Seismic Design Criteria Research(II), Ministry of Construction and Transportation, (1997).
  7. K.S. Park, "9.12 Earthquake and Disaster Prevention Comprehensive Measures", Journal of Korean Society of Hazard Mitigation, vol.17, no.5, (2017).
  8. J.W. Park, D.H. Lee, J.D. Koo, K.S. Noh, "Development of Evaluation Factor of Certification System for Korean Green Road", Journal of Korea Institute of Construction Engineering and Management, vol.15, no.6, pp.16-25, (2014). https://doi.org/10.6106/KJCEM.2014.15.6.016
  9. 건설교통부, 철도건설규칙, (2009).
  10. J. Kang, "Seismic Performance Evaluation According to Seismic Retrofit Techniques of Existing School Buildings", Journal of The Korean Society of Industry Convergence, vol.15, no.1, pp.29-36, (2012). https://doi.org/10.21289/KSIC.2012.15.1.029