의치상레진의 3D 프린팅 출력 각도가 Candida albicans의 부착에 미치는 영향

The build angle of 3D printing denture base resin on candida albicans adhesion.

  • 박수정 (단국대학교 치과대학 치과보철학교실) ;
  • 송영균 (단국대학교 치과대학 치과보철학교실)
  • Park, Su-Jung (Department of prosthodontics, College of Dentistry, Dankook University) ;
  • Song, Young-Gyun (Department of prosthodontics, College of Dentistry, Dankook University)
  • 투고 : 2019.06.28
  • 심사 : 2019.10.11
  • 발행 : 2019.12.31

초록

Purpose: The purpose of this study is to compare the adhesion of Candida albicans according to build angle in 3D printing denture base resin. Methods: The 3D printing was performed by setting the build angle of the disk type specimen designed by CAD program at 0 degree, 30 degrees, 60 degrees, and 90 degrees. Surface roughness was measured using a non-contact 3D microsurface profiler. The specimens were incubated in Candida albicans suspension for 24 hours. The attached Candida albicans were detached by cell scraper. The suspension of detached C. albicans was serially diluted and plated on Trypticase soy broth. After 48 hours of incubation, total colony forming unit was counted. Results: There was no significant difference in surface roughness(Sa) between the test groups, but the interlayer boundary was observed. There was no statistically significant difference in total colony forming units of Candida albicans between the test groups. Conclusion: There was no difference in the average surface roughness and adhesion of Candida albicans between the specimens. It is considered that the setting of the build angle should be set considering the accuracy or strength rather than the roughness of the surface.

키워드

참고문헌

  1. Murray MD, Darvell BW. The evolution of the complete denture base. Theories of complete denture retention--a review. Part 3. Aust Dent J. 1993;38(5):389-93. https://doi.org/10.1111/j.1834-7819.1993.tb05521.x
  2. Klotz SA, Drutz DJ, Zajic JE. Factors governing adherence of Candida species to plastic surfaces. Infect Immun. 1985;50(1):97-101. https://doi.org/10.1128/iai.50.1.97-101.1985
  3. Webb BC, Thomas CJ, Willcox MD, Harty DW, Knox KW. Candida-associated denture stomatitis. Aetiology and management: a review. Part 3. Treatment of oral candidosis. Aust Dent J. 1998;43(4):244-9. https://doi.org/10.1111/j.1834-7819.1998.tb00172.x
  4. Lima JM, Anami LC, Araujo RM, Pavanelli CA. Removable partial dentures: use of rapid prototyping. J Prosthodont. 2014;23(7):588-91. https://doi.org/10.1111/jopr.12154
  5. Laverty DP, Thomas MBM, Clark P, Addy LD. The Use of 3D Metal Printing (Direct Metal Laser Sintering) in Removable Prosthodontics. Dent Update. 2016;43(9):826-8, 31-2, 34-5. https://doi.org/10.12968/denu.2016.43.9.826
  6. Stansbury JW, Idacavage MJ. 3D printing with polymers: Challenges among expanding options and opportunities. Dent Mater. 2016;32(1):54-64. https://doi.org/10.1016/j.dental.2015.09.018
  7. Congalton RG. A review of assessing the accuracy of classifications of remotely sensed data. Remote Sensing of Environment. 1991;37(1):35-46. https://doi.org/10.1016/0034-4257(91)90048-B
  8. Osman RB, Alharbi N, Wismeijer D. Build Angle: Does It Influence the Accuracy of 3D-Printed Dental Restorations Using Digital Light-Processing Technology? Int J Prosthodont. 2017;30(2):182-8. https://doi.org/10.11607/ijp.5117
  9. Chockalingam K, Jawahar N, Chandrasekar U, Ramanathan KN. Establishment of process model for part strength in stereolithography. Journal of Materials Processing Technology. 2008;208(1):348-65. https://doi.org/10.1016/j.jmatprotec.2007.12.144
  10. Ishida Y, Miyasaka T. Dimensional accuracy of dental casting patterns created by 3D printers. Dent Mater J. 2016;35(2):250-6. https://doi.org/10.4012/dmj.2015-278
  11. Saleh WK, Ariffin E, Sherriff M, Bister D. Accuracy and reproducibility of linear measurements of resin, plaster, digital and printed study-models. J Orthod. 2015;42(4):301-6. https://doi.org/10.1179/1465313315Y.0000000016
  12. Alharbi N, Osman R, Wismeijer D. Effects of build direction on the mechanical properties of 3D-printed complete coverage interim dental restorations. J Prosthet Dent. 2016;115(6):760-7. https://doi.org/10.1016/j.prosdent.2015.12.002
  13. Alharbi N, Osman RB, Wismeijer D. Factors Influencing the Dimensional Accuracy of 3D-Printed Full-Coverage Dental Restorations Using Stereolithography Technology. Int J Prosthodont. 2016;29(5):503-10. https://doi.org/10.11607/ijp.4835
  14. Teughels W, Van Assche N, Sliepen I, Quirynen M. Effect of material characteristics and/or surface topography on biofilm development. Clin Oral Implants Res. 2006;17 Suppl 2:68-81. https://doi.org/10.1111/j.1600-0501.2006.01353.x
  15. Kuhar M, Funduk N. Effects of polishing techniques on the surface roughness of acrylic denture base resins. J Prosthet Dent. 2005;93(1):76-85. https://doi.org/10.1016/j.prosdent.2004.10.002
  16. Totu EE, Nechifor AC, Nechifor G, Aboul-Enein HY, Cristache CM. Poly(methyl methacrylate) with TiO2 nanoparticles inclusion for stereolitographic complete denture manufacturing - the fututre in dental care for elderly edentulous patients? J Dent. 2017;59:68-77. https://doi.org/10.1016/j.jdent.2017.02.012
  17. Bollen CM, Papaioanno W, Van Eldere J, Schepers E, Quirynen M, van Steenberghe D. The influence of abutment surface roughness on plaque accumulation and peri-implant mucositis. Clin Oral Implants Res. 1996;7(3):201-11. https://doi.org/10.1034/j.1600-0501.1996.070302.x
  18. Nevzatoglu EU, Ozcan M, Kulak-Ozkan Y, Kadir T. Adherence of Candida albicans to denture base acrylics and silicone-based resilient liner materials with different surface finishes. Clin Oral Investig. 2007;11(3):231-6. https://doi.org/10.1007/s00784-007-0106-3
  19. Verran J, Maryan CJ. Retention of Candida albicans on acrylic resin and silicone of different surface topography. J Prosthet Dent. 1997;77(5):535-9. https://doi.org/10.1016/S0022-3913(97)70148-3