Simulation of an X-ray Fresnel Zone Plate with Nonideal Factors

  • Chen, Jie (Shanghai Engineering Center of Ultra-precision Optical Manufacturing, Fudan University) ;
  • Fan, Quanping (Research Center of Laser Fusion, China Academy of Engineering Physics) ;
  • Wang, Junhua (Shanghai Engineering Center of Ultra-precision Optical Manufacturing, Fudan University) ;
  • Yuan, Dengpeng (Institute of Materials, China Academy of Engineering Physics) ;
  • Wei, Lai (Research Center of Laser Fusion, China Academy of Engineering Physics) ;
  • Zhang, Qiangqiang (Research Center of Laser Fusion, China Academy of Engineering Physics) ;
  • Liao, Junsheng (Institute of Materials, China Academy of Engineering Physics) ;
  • Xu, Min (Shanghai Engineering Center of Ultra-precision Optical Manufacturing, Fudan University)
  • Received : 2019.06.21
  • Accepted : 2019.09.16
  • Published : 2020.02.25

Abstract

Fresnel zone plates have been widely used in many applications, such as x-ray telescopes, microfluorescence, and microimaging. To obtain an x-ray Fresnel zone plate, many fabrication methods, such as electron-beam etching, ion-beam etching and chemical etching, have been developed. Fresnel zone plates fabricated by these methods will inevitably lead to some nonideal factors, which have an impact on the focusing characteristics of the zone plate. In this paper, the influences of these nonideal factors on the focusing characteristics of the zone plate are studied systematically, by numerical simulations based on scalar diffraction theory. The influence of the thickness of a Fresnel zone plate on the absolute focusing efficiency is calculated for a given incident x-ray's wavelength. The diffraction efficiency and size of the focal spot are calculated for different incline angles of the groove. The simulations of zone plates without struts, with regular struts, and with random struts are carried out, to study the effects of struts on the focusing characteristics of a zone plate. When a Fresnel zone plate is used to focus an ultrashort x-ray pulse, the effect of zone-plate structure on the final pulse duration is also discussed.

Keywords

References

  1. D. Attwood, Soft X-ray and Extreme Ultraviolet Radiation: Principles and Applications (Cambridge University Press, New York, UK, 1999).
  2. C. G. Schroer, "Focusing hard x-rays to nanometer dimensions using Fresnel zone plates," Phys. Rev. B 74, 033405 (2006). https://doi.org/10.1103/physrevb.74.033405
  3. J. Reinspach, M. Lindblom, M. Bertilson, O. V. Hofsten, H. M. Hertz, and A. Holmberg, "13 nm high-efficiency nickel-germanium soft x-ray zone plates," J. Vac. Sci. Technol. B 29, 011012 (2011).
  4. K. Jefimovs, O. Bunk, F. Pfeiffer, D. Grolimund, J. F. V. D. Veen, and C. David, "Fabrication of Fresnel zone plates for hard X-rays," Microelectron. Eng. 84, 1467-1470 (2007). https://doi.org/10.1016/j.mee.2007.01.112
  5. V. V. Lider, "Zone plates for X-ray focusing," J. Surf. Invest.: X-ray, Synchrotron Neutron Tech. 11, 1113-1127 (2017). https://doi.org/10.1134/s1027451017060155
  6. J. Vila-Comamala, K. Jefimovs, J. Raabe, T. Pilvi, R. H. Fink, M. Senoner, A. Maasdorf, M. Ritala, and C. David, "Advanced thin film technology for ultrahigh resolution X-ray microscopy," Ultramicroscopy 109, 1360-1364 (2009). https://doi.org/10.1016/j.ultramic.2009.07.005
  7. K. Keskinbora, C. Grevent, M. Bechtel, M. Weigand, E. Goering, A. Nadzeyka, L. Peto, S. Rehbein, G. Schneider, R. Follath, J. Vila-Comamala, H. Yan, and G. Schutz, "Ion beam lithography for Fresnel zone plates in X-ray microscopy," Opt. Express 21, 11747-11756 (2013). https://doi.org/10.1364/OE.21.011747
  8. I. A. Artyukov, I. N. Bukreeva, V. A. Chernov, R. M. Feshchenko, K. M. Golant, W. Jark, S. V. Lavrishchev, A. N. Mitrofanov, A. V. Popov, and A. V. Vinogradov, "Zone plates for hard X-rays fabricated with the SPCVD technology," Nucl. Instrum. Methods Phys. Res. Sect. A 603, 66-68 (2009). https://doi.org/10.1016/j.nima.2008.12.161
  9. C. David, B. Nohammer, and E. Ziegler, "Wet etching of linear Fresnel zone plates for hard X-rays," Microelectron. Eng. 61-62, 987-992 (2002). https://doi.org/10.1016/S0167-9317(02)00489-6
  10. P. P. Ilinski, B. P. Lai, N. J. Bassom, J. Donald, and G. J. Athas, "X-ray zone plate fabrication using a focused ion beam," Proc. SPIE 4145, 311-316 (2001).
  11. P. Tiwari, P. Mondal, A. K. Srivastava, H. Srivastava, R. Dhawan, and S. Rai, "Fabrication of tungsten Fresnel zone plates for hard x-rays using wet etching," J. Vac. Sci. Technol. B 35, 051602 (2017). https://doi.org/10.1116/1.4999933
  12. S. Tamura, M. Yasumoto, N. Kamijo, Y. Suzuki, M. Awaji, A. Takeuchi, K. Uesugi, Y. Terada, and H. Takano, "New approaches to fabrication of multilayer Fresnel zone plate for high-energy synchrotron radiation X-rays," Vacuum 80, 823-827 (2006). https://doi.org/10.1016/j.vacuum.2005.11.004
  13. Q. Fan, Y. Liu, Z. Yang, L. Wei, Q. Zhang, Y. Chen, F. Hu, C. Wang, Y. Gu, W. Zhou, G. Jiang, and L. Cao, "Focusing single-order diffraction transmission grating with a focusing plane perpendicular to the grating surface," Opt. Express 23, 16281-16288 (2015). https://doi.org/10.1364/OE.23.016281
  14. Q. Fan, S. Wang, Z. Yang, L. Wei, F. Hu, H. Zang, Q. Zhang, C. Wang, G. Jiang, and L. Cao, "The realization of long focal depth with a linear varied-area zone plate," J. Mod. Opt. 64, 244-250 (2016).
  15. H. P. Zang, C. K. Wang, Y. L. Gao, W. M. Zhou, L. Y. Kuang, L. Wei, W. Fan, W. H. Zhang, Z. Q. Zhao, L. F. Cao, Y. Q. Gu, B. H. Zhang, G. Jiang, X. L. Zhu, C. Q. Xie, Y. D. Zhao, and M. Q. Cui, "Elimination of higherorder diffraction using zigzag transmission grating in soft x-ray region," Appl. Phys. Lett. 100, 111904 (2012). https://doi.org/10.1063/1.3693395
  16. Center for X-Ray Optics (CXRO), Index of Refraction, (The Center for X-ray Optics, 2010), http://henke.lbl.gov/optical_constants/getdb2.html.
  17. W. Chao, E. Anderson, G. P. Denbeaux, B. Harteneck, J. A. Liddle, D. L. Olynick, A. L. Pearson, F. Salmassi, C. Y. Song, and D. T. Attwood, "20-nm-resolution soft x-ray microscopy demonstrated by use of multilayer test structures," Opt. Lett. 28, 2019-2021 (2003). https://doi.org/10.1364/OL.28.002019