Abstract

Along with dust collection efficiency, pressure loss is a very important cyclone operation factor. A severe rise in pressure loss causes the problem of cost. To solve the problem, the method connecting axial-vane type cyclones in parallel is suggested recently. The axial vane type cyclone dust collector applied in this study is a small portable type. Multiple cyclones are installed in a round type. The basic performance test on the axial vane type cyclone dust collector was conducted. As a result, the cut size reduced along with a rise in the wind velocity of the cyclone dust collector inlet. According to the test on dust collection efficiency, the effect of dust collection began to appear in the range of 3㎛ and dust collection efficiency was greatly improved at 5 ㎛. The noise of the cyclone dust collector well met the fan sound power level of KSB 6361.

Keywords

References

  1. Copper, C. D. and Alley F. C., "Air Pollution Control: A Design Approach", Waveland Press, New York, pp. 138-150, (1994).
  2. Zhou, L. X. and Soo S. L., "Gas-Solid Flow and Collection of Solids in a Cyclone Separator", Powder Technology, Vol. 63, pp. 45-53, (1990). https://doi.org/10.1016/0032-5910(90)80006-K
  3. J. S. Kim, T. U. Lee, T. H. Kang, I. K. Kim, Y. S. Kim, "A CFD Analysis on Axial Inlet Cyclone using Realizable k-${\varepsilon}$ Turbulence Model", Conference Proceedings of KSME Spring Annual Meeting, pp. 1327-1332, (2006).
  4. J. I. Ju, Y. S. Choi, Y. K. Lee, T. H. Kim and S. Y. Kim, "Numerical S쇼요 of Turbulent Flow in a Hydrocyclone", Journal of Flow Machinery, Vol. 6, No. 2, pp. 34-40, (2003). https://doi.org/10.5293/KFMA.2003.6.2.034
  5. J. K. Young, C. N. Kim and Y. M. Jo, "A Numerical Analysis on the Flow Characteristics and the Collection Efficiency for Fine Particles in a Cyclone", Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 20, No. 2, pp. 144-153, (2008).
  6. Y. S. Cho, S. W. Lee, K. S. Woo, Y. B. Yoon, Y. J. Park, D. Y. Lee, H. C. Kim and B. C. Na, "A Numerical Analysis of Flow Characteristics and Oil Separation Performance for Cyclone Oil separator designs", Transactions of KSAE, Vol. 16, No. 5, pp. 22-28, (2008).
  7. H. J. Shin, Y. W. Lee, J. H. Park, J. H. Kim, C. W. Lee and S. C. Jang, "A Numerical Study on the Performance Analysis for Design Optimization of Axial-Vane Type Cyclone" Proceedings of the KSMTE Spring Annual Meeting, pp. 537-538, (2011).
  8. C. E. Lapple and C. B. Shepherd, "Flow pattern and pressure drop in dust cyclone separator", Ind. & Eng. Chem., Vol. 31 No. 8, pp. 972-984, (1939). https://doi.org/10.1021/ie50356a012