DOI QR코드

DOI QR Code

Structural Performance of One-way Void Plywood Slab System with form work Pane

거푸집 패널이 부착된 1방향 중공슬래브의 구조 성능

  • 허무원 (단국대학교 건축공학과) ;
  • 채경훈 (단국대학교 건축공학과) ;
  • 황규석 ((주)윈하이텍, 기술연구소) ;
  • 윤성호 (광장구조기술사사무소) ;
  • 박태원 (단국대학교 건축공학과)
  • Received : 2020.10.30
  • Accepted : 2020.12.02
  • Published : 2021.02.28

Abstract

In this study, we developed Void Plywood Slab (VPS) that improved the shape of existing hollow materials. Its performance was evaluated through one-way flexural and one-way shear tests using the developed VPS. As a result of the one-way flexural performance tests of VPS, the yield load value for FPS series(longitudinal direction specimens with hollow materials) was approximately 97.5% compared to FPS-00(without hollow materials) specimen. The tests showed that the yield load was not much different. In addition, FNS series(transverse direction specimens with hollow materials) also represented about 97% of FPS-00 specimen. The one-way flexural performance was shown to have little impact from void materials. Therefore, it is confirmed that the presented system is applicable to the VPS to the slab design. The results of the one-way shear performance tests of VPS showed that it was about 92% compared to the SS-00(without hollow materials) specimen. These results were somewhat insufficient for the SS-00 specimen. Shear strength equation is expressed as the sum of shear force by concrete and shear force by reinforcement. However, in the case of void slab, it is believed that the concrete section has been deleted by the void material. However, the strength of the structure applied to the shear design, as with the flexural design, is also applied to the design based on the yield load value.

이 연구에서는 기존 중공재의 형상을 개선한 거푸집용 중공슬래브를 개발하였고, 개발된 VPS를 활용하여 휨 및 전단 실험을 수행하여 그 성능을 평가하였다. VPS의 휨 성능 실험 결과, FPS 계열 실험체의 경우 항복 하중 값은 FPS-00 실험체 대비 약 97.5%를 나타내고 있어 항복하중 값에는 큰 차이가 없는 것으로 나타났다. 또한, FNS계열 실험체도 FPS-00 실험체 대비 약 97%를 나타내어 휨 성능에는 중공재에 의한 영향이 거의 없는 것으로 나타났다. 따라서 슬래브 시스템을 VPS로 슬래브 설계에 적용할 때 건축구조기준의 설계식으로 적용하는데 문제가 없을 것으로 판단된다. VPS의 전단 성능 실험 결과, SS-00 실험체 대비 약 92%로 나타나 SS-00 실험체에 비하여 다소 부족한 것으로 나타났다. 이는 전단강도 식이 콘크리트에 의한 전단력과 철근에 의한 전단력의 합으로 표현되는 설계 식에 따라 중공재에 의하여 콘크리트 단면이 삭제되었기 때문인 것으로 판단된다. 하지만, 휨설계와 동일하게 전단설계에 적용되는 구조체의 내력도 최대하중 값을 기준으로 하는 것이 아니라 항복 하중 값을 기준으로 설계에 적용하게 된다.

Keywords

References

  1. Jung, M. G., Choi, C. S. (2017) An Experimental Study on the Flexural Capacity of a On-way Void Slab with Removable Deck Plate. Journal of the Korea Concrete Institute, 29(5), 437-445. https://doi.org/10.4334/JKCI.2017.29.5.437
  2. Lee, Y. J., Kim, H. G., Kim, M. J., Kim, D. H., Kim, K. H., (2020) Evaluation of Flexural Performance for Prestressed Concrete Hollow Core Slabs, Journal of the Korea Concrete Institute, 32(2), 193-200. https://doi.org/10.4334/JKCI.2020.32.2.193
  3. Lee, Y. J., Kim, H. K., Kim, M. J., Lee, J. S., and Kim, K. H., (2019) Evaluation of Structural Performance for Prestressed Concrete Hollow Core Slabs. Journal of the Korea Concrete Institute 31(5), 505-512. https://doi.org/10.4334/jkci.2019.31.5.505
  4. Park, M. K., Lee, D. H., Han, S. J., and Kim, K. D., (2019) Web-shear Capacity of Thick Precast Prestressed Hollow-core Slabs Units Produced by Extrusion Method. InternationalJournal of Concrete Structures and Materials 13(7), 19-32. https://doi.org/10.1186/s40069-018-0329-5
  5. Cho. G. Y., Park. Y. C., Choi. C. S., (2018), An Experimental Study on the One-way Shear Strength of Void Slabs with Automatic Prefabrication of Welded Wire Truss, Journal of the Korea Concrete Institute, 30(3). pp. 305-314. https://doi.org/10.4334/JKCI.2018.30.3.305
  6. Son. H. S., Cho. S. H., Roh. Y. S., Yoon. S. H., (2018), Evaluation on Flexural Performance of Void Slabs with Application of Buoyancy Protection Equipment for Void Foamer, Journal of the Korea Concrete Institute, 30(4). pp. 403-410. https://doi.org/10.4334/jkci.2018.30.4.403
  7. Jung. M. G., Choi. C. S., (2017), An Experimental Study on the Flexural Capacity of a One-way Void Slab with removable Deck Plate, Journal of the Korea Concrete Institute, 29(5). pp. 437-445. https://doi.org/10.4334/JKCI.2017.29.5.437
  8. Choi, H. M., Park, T. W., Paik, I. K., Kim, J. S., Han, J. Y., (2015) Shear Performance of Board-type Two-way Voided Slab. Journal of the Korea Concrete Institute 27(6), 651-659. https://doi.org/10.4334/JKCI.2015.27.6.651
  9. National Environmental Dispute Resolution Commission, (2016), 25 Years of History in Environmental Dispute Conciliation(Based on 25 Instances), National Environmental Dispute Resolution Commission, Se-jong.
  10. Ministry of Land, Infrastructure and Transport (2015), Standard floor finishing and structures for interlayer noise prevention (p. 319), Governing City: Ministry of Land, Infrastructure and Transport.
  11. Aldejohann, M. and Schnellenbach-Held, M. (2003) Investigations on the Shear Capacity of Biaxial Hollow Slabs-Test Results and Evaluation. Darmstadt Concrete, 18, 1-11.
  12. Aldejohann, M. and Schnellenbach-Held, M. (2005) Biaxial hollow slabs, theory and tests. Betonwerk Fertigteil-Technik, 71(10), 50-59.
  13. Kim, S. M., Jang, T. Y., and Kin, S. S. (2009) Structural Performance Tests of Two-Way Void Slabs. Journal of the Korea Architectural Institute, 25(8), 35-42.
  14. Yoon, S. H., (2014), Structural Performance and Serviceability of Void Slabs with Deck Plate and Polystyrene Form, Ph. D. Dissertation, Dankook University, 16-20.
  15. Yoon, S. H., (2013), Hollow Slab Structure Using Multifunctional Rail and Construction Method Thereof Patent of Korea, 10-1318721.