Abstract

In this paper, we introduce a novel approach to enhance document security by integrating Computer Generated Hologram(CGH) encryption technology with a system for document encryption, printing, and subsequent verification using a smartphone application. The proposed system enables the encryption of documents using CGH technology and their printing on the edges of the document, simplifying document verification and validation through a smartphone application. Furthermore, the system leverages high-resolution smartphone cameras to perform online verification of the original document and supports offline document decryption, ensuring tamper detection even in environments without internet connectivity. This research contributes to the development of a comprehensive and versatile solution for document security and integrity, with applications in various domains.

Keywords

Acknowledgement

This research was supported by the MSIT(Ministry of Science and ICT), Korea, under the ITRC(Information Technology Research Center) support program(IITP-2023-2020-0-01846) supervised by the IITP(Institute for Information & Communications Technology Planning & Evaluation)

References

  1. Thomas W.; Frey, H.; Jean Page. Virtual HUD using an HMD, Proceedings of SPIE - The International Society for Optical Engineering 2001, Volume 4361, Helmet- and Head-Mounted Displays VI.
  2. Choi, P.H.; Choi, Y.H.; Park, M.S.; Lee, S.H. Non-glasses Stereoscopic 3D Floating Hologram System using Polarization Technique, The Institute of Internet, Broadcasting and Communication 2019, Volume 8, Issue 1, pp. 18-23.
  3. Toshiaki, Y.; Nahomi M.; Kazuhisa Y. Holographic Pyramid Using Integral Photography, Proceedings of the 2nd World Congress on Electrical Engineering and Computer Systems and Science 2016, MHCI 109, pp. 16-17.
  4. Reichelt, S.; Haussler, R.; Futterer, G.; Leister N. Depth cues in human visual perception and their realization in 3D displays, SPIE Proceedings, 2010, Volume 7690, pp. 111-112.
  5. De Silva, V.; Fernando, A.; Worrall, S.; Arachchi, H.K.; Kondoz, A. Sensitivity analysis of the human visual system for depth cues in stereoscopic 3-D displays. IEEE Transactions on Multimedia, 2011, Volume 13, No. 3, pp. 498-506.
  6. Krumholz, D.M.; Fox, R.S.; Ciuffreda, K.J. Short-term changes in tonic accommodation. Investigative Ophthalmology & Visual Science 1986, Volume 27, pp. 552-557.
  7. Avudainayagam, K. V.; Avudainayagam, C. S. Holographic multivergence target for subjective measurement of the astigmatic error of the human eye. Opt. Lett 2007, Volume 32, pp. 1926-1928.
  8. Ciuffreda, K.J.; Kruger, P. B. Dynamics of human voluntary acommodation, Am. J. Optom. Physiol 1988, Volume 65, pp. 365-370.
  9. Cacho, P., Garcia, A., Lara, F.; Segui, M. M. Binocular acommodative facilty testing reliabilty, Optom. Vis 1992, Volume 4, pp. 314-319.
  10. Bharadwaj S.R.; Candy T.R. Acommodative and vergence responses to conflicting blur and disparity stimuli during development, Journal of Vision 2009, Volume 9), pp. 1-18.
  11. Iribarren, R.; Fornaciari, A.; Hung, G. K. Effect of cumulative near work on accommodative facility and asthenopia, Int. Ophthalmol 2001, Volume 24, pp. 205-212.
  12. Rosenfield, M.; Ciufreda, K. J. Effect of surround propinquity on the open-loop accommodative response. Invest Ophthalmal 1991, Volume 32, pp. 142-147.
  13. Rosenfield, M.; Ciufreda, K. J.; Hung, G. K.; Gilmartin, B. Tonic accommodation: A review. I. Basic aspects. Ophthalmic Physiol 1993, Volume 13, pp. 266-284.
  14. McBrien, N.A.; Millodot, M. The relationship between tonic accommodation and refractive error. Investigative Ophthalmology & Visual Science 1987, Volume 28, pp. 997-1004.
  15. Krumholz, D.M.; Fox, R.S.; Ciuffreda, K.J. Short-term changes in tonic accommodation. Investigative Ophthalmology & Visual Science 1986, Volume 27, pp. 552-557.
  16. Nadezhda, V.; Pavel, S. Application of Photopolymer Materials in Holographic Technologies. polymers 2019, 11(12)
  17. Hanle, Z.; Huan, D.; Minyang, H.; Dahai, L.; Qionghua, Wang. Dual-View Integral Imaging 3D Display Based on Multiplexed Lens-Array Holographic Optical Element. Applied sciences 2019, 9(18).
  18. Maria, A. F.; Valerio, S.; Giuseppe, C. Volume Holographic Optical Elements as Solar Concentrators: An Overview. Applied sciences 2019, 9(18)
  19. Jung-ping, L.; Tatsuki, T.; Yoshio, H.; Ting-chung P. Incoherent Digital Holography: A Review. Applied sciences 2018, 8(1)
  20. Reid, V.; Adam, R.; Elvis C. S. C.; Terry, M. P. Hologram stability evaluation for Microsoft HoloLens. Spie 2017, Volume 10136.
  21. Oh, J. Y.; Park, J. H.; Park, J. M. Virtual Object Manipulation by Combining Touch and Head Interactions for Mobile Augmented Reality. Applied sciences 2019, 9(14).
  22. Takeda, T.; Hashimoto K.; Hiruma N.; Fukui Y. Characteristics of accommodation toward aparent depth. Vision Research 1999, Volume 39, pp. 2087-2097.
  23. Davies, L.N.; Mallen, E.A.; Wolffsohn, J.S.; Gilmartin, B. Clinical evaluation of the Shin-Nippon NVision-K5001/Grand Seiko WR-5100K autorefractor. Optom 2003, Volume 80, pp. 320-324.
  24. Gentet, P.; Gentet, Y.; Lee, S. H. Ultimate 04 the new reference for ultra-realistic color holography. In Emerging Trends Innovation in ICT(ICEI), 2017 International Conference on IEEE, 2017, pp. 162-166.
  25. Gentet, P.; Gentet, Y.; Lee, S. H. New LED's wavelengths improve drastically the quality of illumination of pulsed digital holograms. In Digital Holography and Three-Dimensional Imaging, 2017, pp. 209.
  26. Moses, L. E. Non-parametric statistics for psychological research. Psychological Bulletin, 1952, Volume 49, No. 2, pp.122-143.
  27. Andrew, J. K. Parametric versus non-parametric statistics in the analysis of randomized trials with non-normally distributed data. BMC Medical Research Methodology, 2005, Volume 5, No. 35.
  28. Davison, M. L.; Sharma, A. R. Parametric statistics and levels of measurement. Psychological Bulletin, 1988, Volume 104, pp.137-144.