• Title/Summary/Keyword: %24CO_2%24 concentration

Search Result 573, Processing Time 0.036 seconds

Laboratory Measurements on the Uptake of Carbon Monoxide by Soils (토양의 일산화탄소 제거에 관한 연구)

  • Myung Ja Kim
    • Journal of the Korean Chemical Society
    • /
    • v.27 no.1
    • /
    • pp.31-37
    • /
    • 1983
  • The consumption of atmospheric carbon monoxide by soil was measured under laboratory conditions in different types of soils. Laboratory experiments were performed with humus containing high proportion of organic matter, roadside soils, and humus and roadside soils previously exposed to high concentration of CO by reusing in the experiment. CO concentrations in the 18.2 l-reaction vessel were varied from 2,000 ppm to 24,000ppm to estimate the effectiveness of CO consumption at high level of CO. The uptake of CO by soil was measured by gas chromatography using a TCD detector. The control experiments conducted along with the soil experiments evidently indicated that the potting soil is responsible for CO consumption. Humus showed much higher CO uptake rates compared with the soil taken from roadside. The humus reused in the experiment showed somewhat higher rates(15%) of uptake than the fresh one. The soil's ability to remove CO from the test atmosphere reached a maximum near the CO concentration of 13,000 ppm in the range of $9,000~24,000ppm$. The addition of streptomycin did not influence the removal capacity of soil significantly, whereas 10% saline solution remarkably prevented CO uptake of the humus sample.

  • PDF

Hydrogen Conversion of Syngas by Using WGS Reaction in a Coal Gasifier (가스화기에서 WGS 반응을 통한 합성가스의 수소 전환)

  • Lee, See Hoon;Kim, Jung Nam;Eom, Won Hyun;Baek, Il Hyun
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.24 no.1
    • /
    • pp.12-19
    • /
    • 2013
  • A gasification process with pre-combustion $CO_2$ capture process, which converts coal into environment-friendly synthetic gas, might be promising option for sustainable energy conversion. In the coal gasification for power generation, coal is converted into $H_2$, CO and $CO_2$. To reduce the cost of $CO_2$ capture and to maximize hydrogen production, the removal of CO and the additional production of hydrogen might be needed. In this study, a 2l/min water gas shift system for a coal gasifier has been studied. To control the concentration of major components such as $H_2$, CO, and $CO_2$, MFCs were used in experimental apparatus. The gas concentration in these experiments was equal with syngas concentration from dry coal gasifiers ($H_2$: 25-35, CO: 60-65, $CO_2$: 5-15 vol%). The operation conditions of the WGS system were $200-400^{\circ}C$, 1-10bar. Steam/Carbon ratios were between 2.0 and 5.0. The commercial catalysts were used in the high temperature shift reactor and the low temperature shift reactor. As steam/carbon ratio increased, the conversion (1-$CO_{out}/CO_{in}$) increased from 93% to 97% at the condition of CO: 65, $H_2$: 30, $CO_2$: 5%. However the conversion decreased with increasing of gas flow and temperature. The gas concentration from LTS was $H_2$: 54.7-60.0, $CO_2$: 38.8-44.9, CO: 0.3-1%.

Membrane Process Development for $CO_2$ Separation of Flaring Gas (Flaring 가스의 $CO_2$ 분리를 위한 분리막 공정 기술개발)

  • Kim, Se Jong;Kim, Hack Eun;Cho, Won Jun;Ha, Seong Yong
    • Membrane Journal
    • /
    • v.23 no.5
    • /
    • pp.384-391
    • /
    • 2013
  • We prepared composite membrane which was made with polysulfone supported hollow fiber membrane coated with Hyflon AD to eliminate $CO_2$ gas from mixed-gases which were generated in DME manufacturing processes. The performance of module about simulated flaring gas was measured by using manufactured composite membrane. 1-stage evaluation result shows $CO_2$ concentration was below 3% at 1.2 MPa and at Stage cut 0.24 above. In addition $CO_2$ removal rate and $CH_4$ recovery rate was 80% respectively at the same condition. 2-stage evaluation result shows, when the $CO_2$ concentration of product gas was fixed at 5%, recycled $CO_2$ at stage cut 0.074 had the same concentration as the feed gas and the recovery rate of $CH_4$ was 99% at the moment.

Quantitative Analysis of CO2 Reduction by Door-opening in the Subway Cabin (출입문 개폐에 의한 전동차 객실 CO2 저감효과 분석)

  • Kwon, Soon-Bark;Cho, Young-Min;Park, Duck-Shin;Park, Eun-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.2
    • /
    • pp.153-161
    • /
    • 2008
  • The guidelines for indoor air quality of public transportations such as subway, train and bus was presented by Korean Ministry of Environment last end of year 2006 based on the great consequence of indoor air quality in daily life. Two main parameters, carbon dioxide($CO_2$) and particulate matters smaller than $10\;{\mu}m(PM_{10})$, were selected as index pollutants for the management of indoor air quality. The former pollutant, $CO_2$, is regarded as index of ventilation status and the major source of $CO_2$ in the train or subway is the exhalation of passengers. It is publically perceived that the high $CO_2$ concentration in a crowded subway will be reduced and ventilated with outdoor air by door-opening taken every 2 or 3 minutes when the train stops each station. However, there has not been any scientific proof and quantitative information on the effect of door-opening on the $CO_2$ reduction by ventilation with outdoor air. In this study, $CO_2$ concentration and number of passengers were measured at each station on the 3 lines of Korail metropolitan subway. In order to evaluate the effect of $CO_2$ reduction by door opening, the theoretical approach using the $CO_2$ balance equation was performed. By comparing the predicted data with monitoring one, the optimum $CO_2$ dilution factor was determined. For the first time, it was quantified that about 35% of $CO_2$ concentration in the subway indoor was removed by the door-opening at each station.

Ethanol Production from Raw Starch by Co-Immobilized Mixed Rhizopus japonicus and zymomonas mobilis (Rhizopus japonicus와 Zymomonas mobilis의 혼합고정화 배양계에 의한 생전분으로부터 에탄올 생산)

  • 최수철;이상원;박석규;성찬기;손봉수;성낙계
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.25 no.4
    • /
    • pp.708-714
    • /
    • 1996
  • Ethanol production from raw starch was performed using the co-immobilized culture system of Rhizopu japonicus and zymomonas mobilis(R-Z). Glucose Production in immobilized R. japonicus culture was 2-fold higher than that in free cell culture. Ethanol production was 1.67g/L(Yp/s, 0.094) and 6.549/L(Yp/s, 0.38) in R-Z and R-Z 24 culture system, respectively. R-Z system was modified and designated as R-Z 24 system by replacing cotton plug with silicon check valve after 24h fermentation with R-Z system. Optimal substrate concentration for ethanol production in batch culture was 5%(w/v) and ethanol concentration produced was 15.02g/L(Yp/s, 0.36). Ethanol yield(Yp/s, 0.38) in fed-batch culture of 5 times with 2%(w/v) substrate was equal to that in batch culture of 2%(w/v) substrate.

  • PDF

Effects of Diffusibility of Bubbling Tablet Herbicide Formulations for Paddy Rice (수도용 발포성정제 제초제의 확산성에 미치는 영향)

  • Kim, Man-Ho;Ryang, Kwang-Rok;Lee, Chang-Hyeuk;Shim, Jae-Weon;Kim, Kyung-Hyun;Yoon, Cheol-Su;You, Yong-Man;Pyon, Jong-Yeong
    • The Korean Journal of Pesticide Science
    • /
    • v.9 no.4
    • /
    • pp.401-410
    • /
    • 2005
  • A series of studies involving formulation processes, bubbling activity test, diffusibility test and biological efficacy test was undertaken to develop Jumbo herbicide formulations in paddy rice field. Gas evolution speed from the tablets prepared by different organic acids was in the order of oxalic acid, malonic acid, citric acid, and tartaric acid. The total volume of evolved gas from the tablet and diffusibility of the active ingredient in the submerged water were increased with increase of water temperature; the volume from 1 g of tablet at 10, 15, 25 and $30^{\circ}C$ for 5 minutes after immersion into water was 20, 25, 28, 45, 57 mL, respectively. The concentration of halosulfuron-methyl and pyriminobac-methyl in submerged water at 5, 15, 20 and $30^{\circ}C$ at the 2.4 m distance from the applied spot of the tablet was 20, 48, 85, and 97% of the concentration of treated spot, respectively. The evolved gas volume from the tablets was not affected by pH of submerged water. The concentration of halosulfuron-methyl in different sizes of submerged water within 24 hours after treatment of the tablet was maintained 0.16 ppm, which is ideal concentration at standard dosage regardless of the submerged water area. The concentration of pyriminobac-methyl was also uniformly dispersed in the water within 24 hours after applying it into the submerged water. The wind velocity of 5 m $sec^{-1}$ on concentration distribution of halosulfuron-methyl and pyriminobac-methyl in the submerged water 24 hours after treatment was not influenced; an equal concentration in the up the wind and down the wind from the applied spot was maintained. Spot treatments of one tablet formulations(5 g) including 4 times higher dosage at 4 different spots resulted in even concentration distribution of active ingredient in the water 24 hours after applying it into the submerged water.

Effect of Light Intensity, Temperature and $CO_2$ Concentration on Photosynthesis in Yacon(Polymnia sonchifolia Poepp.& Endl.) (광도, 온도 및 $CO_2$의 농도가 야콘의 광합성에 미치는 영향)

  • Lee, Kang-Soo;Choi, Sun-Young
    • Korean Journal of Medicinal Crop Science
    • /
    • v.9 no.3
    • /
    • pp.232-237
    • /
    • 2001
  • This study was carried out to know the effect of light intensity, temperature and $CO_2$ concentration on photosynthesis and transpiration in yacon(Polymnia sonchifolia Poepp.& Endl.). Light compensation point was ${58\;{\mu}mol\;m^{-2}\;s^{-1}}$and light saturation point was ${1708\;{\mu}mol\;m^{-2}\;s^{-1}}$. Transpiration rate was increased to about 4 mmol${m^{-2}\;s^{-1}}$ with increasing of light intensity to ${2193\;{\mu}mol\;m^{-2}\;s^{-1}}$. The optimum temperature for photosynthesis was ${24^{\circ}C}$ in air. Photosynthesis was gradually reduced as transpiration rate increased from 4 to 8 mmol ${m^{-2}\;s^{-1}}$ in different air temperature. $CO_2$ compensation point was 63 vpm and $CO_2$ saturation point was 1155 vpm and light saturation point was enhanced with increasing of $CO_2$ concentration from 350 vpm to 1300 vpm.

  • PDF

The Influences of Sea Breeze on Air Pollution Concentration in Pusan, Korea (해풍이 부산 지역의 대기 오염 농도에 미치는 영향)

  • Jeon, Byeong-Il;Kim, Yu-Geun;Lee, Hwa-Un
    • Journal of Environmental Science International
    • /
    • v.3 no.4
    • /
    • pp.357-365
    • /
    • 1994
  • Air pollution characteristics and the influence of sea breeze on air pollution concentration were studied using the data measured at 7 air quality continuous monitoring stations in Pusan, 1993. Maximum air pollution concentration in Pusan was Gamjeondong for $SO_2$, Sinpyeongdong for TSP, Daeyeondong for $O_3, Kwangbokdong for $NO_2$, Beomcheondong for CO and all substances were under annual ambient air quality standards. Increased rate of concentration for sea breeze was 24.4% for 502, 31.5% for TSP, 8.0% fort $O_3, 26.7% for $NO_2$, 15.7% for CO. Frequencies distribution of $SO_2$, TSP, $O_3$, $NO_2$, and CO concentration for sea breeze moved toward high concentration class.

  • PDF

An Analysis on HCHO, TVOC, CO2 Concentration of Existing-Housing Indoor-Air in Summer (기존 주택의 하절기 실내 공기중 HCHO, TVOC, CO2 농도 실태 조사분석)

  • Nam, Ki-Cheul;Lee, Young-Han
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.115-122
    • /
    • 2016
  • Purpose: The study is to measure indoor air pollutants concentration of existing housing and to analyze the causes and assess in accordance with the government's criteria. The research result could be used as data for public health through indoor air quality management of existing housing and more as a reference for new housing. Method: It was investigated 24 middle class housings of metropolitan area in summer which have been built for the past 30 years. Concentration of HCHO, TVOC was investigated in living room at morning and night and concentration of $CO_2$ was investigated in living room and master bedroom at morning and night. SKT100-X5 was used for concentration of HCHO, TVOC and ZGm053UK for concentration of $CO_2$. Result: Average concentration of TVOC was 1.31 times more than that of HCHO and standard deviation of that was 1.73 times higher. Average concentration of $CO_2$ was almost nearly close to 1,000ppm being criteria of the Ministry of Environment.

Effect of Gas Atmosphere on In Vitro Development of Bovine Embryos Derived from In Vitro Fertilization (배양기내 GAS 분압의 조성이 소 체외수정란의 체외발육에 미치는 영향에 대한 연구)

  • 이원유;신태영;이병천;황우석
    • Journal of Embryo Transfer
    • /
    • v.10 no.2
    • /
    • pp.121-129
    • /
    • 1995
  • To examine the critical effect of oxygen concentration on embryonic development, in vitro fertilized embryos were cultured in media(TCM199 vs. SOF) supplemented sera(1O% FCS vs. 10% HS) with and without bovine oviduct epithelial cells under two gas atmosphere (5% $CO_2$ in air vs. 5% $CO_2$, 5% $O_2$, 90% $N_2$). Oocytes, obtained from abattoir ovaries, were matured in EGF containing TCM199 medium co-cultured with BOEC for 24 hours, followed by exposure to frozen-thawed, heparin4reated spermatozoa in TALP for 30 hours. And then early embryos(1~2 cell) were cultured in both TCM199 and SOF supplemented with 10% FCS or 10% RS under 5% $CO_2$ in air or 5% COi, 5% $O_2$, 90% $N_2$. Development to morulae and blastocysts was recorded on days 7, after the start of in vitro fertilization. The developmental rates of in vitro fertilized embryos to morulae and blastocysts cultured in SOF with BOEC under 5% $CO_2$, 5% $O_2$, 90% $N_2$(24.4%) were significantly(p<0.05) higher than cultured in SOF with BOEC under 5% $CO_2$ in air(14.1%) at seven days after in vitro fertilization. When early bovine embryos were cultured in TCM 199 and SOF under two different gas atmosphere, there were no significant differences in the developmental rates to morulae and blastocysts between supplements of 10% FCS and 10% HS. The rates of development to morulae and blastocysts were significantly(p<0.01) higher in TCM 199 with BOEC(24.7%) than TCM199 without BOEC(10.9%) under 5% $CO_2$ in air, otherwise SOF without BOEC(36.4%) were significantly (p<0.05) higher than in SOF with BOEC (24.4%) under 5% $CO_2$, 5% $O_2$, 90% $N_2$. In summary, these experiments have proved that the culture system in SOF supplemented 10% ES is effective on in vitro development of early bovine embryos under 5% $CO_2$, 5% $O_2$, 90% $N_2$. In addition, it is effective to development of bovine embryos that TCM 199 should be co-cultured with BOEC and SOF should be cultured without somatic cells under two different gas atmosphere.

  • PDF