• Title/Summary/Keyword: Doppler

Search Result 2,260, Processing Time 0.035 seconds

Myocardial Perfusion after Transmyocardial Mechanical Revascularization in Rat Heart Transplant Model, Acute Model (백서 동종이식 심장모델에서 기계적 경심근 혈관재형성의 심근 혈류 개선 효과 : 급성기 모델)

  • Shinn Sung Ho;Chung Won Sand;Kang Jung Ho;Jeon Yang-Bin
    • Journal of Chest Surgery
    • /
    • v.38 no.7 s.252
    • /
    • pp.468-475
    • /
    • 2005
  • Transmyocardial revascularization (TMR) in end stage ischemic heart disease results in variable clinical responses. We investigated the acute effect of early reperfusion and the angiogenesis after formation of the transmyocardial channel in a transplanted rat heart model with acute myocardial infarction. Material and Method: In the 30 transplanted hearts we induced acute myocardial infarction by ligating the proximal left coronary artery and inserted a porous 22G intravenous cannula into the left ventricle. After ten minutes of reperfusion, we removed the cannula. At every stage, we recorded the heart rate, QRS size, and left coronary arterial blood flow using the electrocardiogram and Doppler. One week later the rats were sacrificed and evaluated for the patency of intramyocardial channels and the angiogenesis. Result: The heart rates after ligation and after cannula insertion were $239.1\pm61.7,\;235.8\pm58.0bpm$ respectively, and they were statistically significantly slower than that of before ligation, $277.6\pm40.3bpm\;(p=0.017,\;p=0.007\;respectively)$. QRS sizes before ligation, after ligation, and after cannula insertion were $3.6\pm3.3mm,\;2.8\pm3.3 mm,\;and\;2.4\pm2.2mm,$respectively, and there was no significant difference in the three groups. Doppler findings after ligation showed that average peak and mean values of coronary perfusion were significantly decreased from $2.11\pm0.17kHz,\;1.25\pm0.22kHz\;to\;0.83\pm0.15kHz,\;0.38\pm0.11kHz$(p<0.05 respectively). After insertion of the porous cannula, the average peak and mean values of coronary perfusion were $0.61\pm0.05kHz\;and\;0.33\pm0.05 kHz$ respectively, but there was no statistically significant change compared to values after ligation. In all cases except one, pathologic findings showed no patent channels in the acute stage, however, one case showed the angiogenesis. Conclusion: We confirmed that TMR in a rat heart transplant model did not show blood flow through the channel in the acute stage. However, reperfusion effect in some cases had a potential for angiogenesis.

Time-related Histopathologic Changes of Fresh Frozen Vascular Xenograft in Pig-to-goat Model (돼지-염소 모델에서 신선 동결된 이종 경동맥 이식편의 시간 경과에 따른 조직병리학적 변화)

  • Chang, Ji-Min;Kim, Won-Gon
    • Journal of Chest Surgery
    • /
    • v.40 no.3 s.272
    • /
    • pp.180-192
    • /
    • 2007
  • Background: As determined from the recent investigations of discordant cardiac xenotransplantation, hyperacute rejection occurs mainly at the endothelial cells in donor microvascular systems, but this does not occur at cardiac valve leaflets or at medium-to-large caliber vessels. On the basis of this background, this study was performed to look into the biocompatibility for transplantation of a middle or large diameter xenogenic blood vessel by conducting xenogenic arterial transplantation with the carotid artery in a pig-to-goat model. Material and Method: The experimental group was composed of 10 pairs of pig-to-goat combinations. They were divided into each period of 1 week, and 1, 3, 6 and 12 months. Four carotid artery grafts obtained through collection of the bilateral carotid arteries from two pigs were preserved at $-70^{\circ}C$ without other treatment, and then they were transplanted into the bilateral carotid arteries of two goats. Doppler ultrasonography was done on a periodic basis after transplantation to evaluate the patency of the grafted blood vessel. At the ends of a predetermined period, the grafts were explanted from the goats and they underwent gross examination. Hematoxylin-eosin and Masson's trichrome staining were conducted. In addition, in order to examine the immunological rejection of the grafted xenogenic blood vessel, immunohistochemical staining was conducted with T-lymphocyte indicator and von Willebrand factor. Result: Two goats at the each one-week period and the one-year period died during the experimental period because of a reason unrelated to the experimental procedure, and the remaining 8 goats survived until the end of each experiment period. On Doppler ultrasonography, unilateral carotid artery occlusion was found in a goat, whose period was specified as 3 months, among the 8 survived goats. However, the vascular patency was maintained well and there was no graft that formed aneurysms in the other goats. On gross examination, the region of vascular anastomosis was preserved well, and calcification of the grafted blood vessel was not shown. Histologically, the endothelial cells of the graft disappeared one week after transplantation, and then there was progressive spread of the recipients' endothelial cells from the anastomotic site. The reendothelialization occurred over the whole graft at one month after transplantation. The neointimal thickening and adventitial inflammation became severe by 3 months after transplantation, but this lessened at 6 months and 12 months, respectively. The rate of CD3 positive cells was very low among the infiltrated inflammatory cells. Conclusion: The fresh-frozen xenogenic artery kept its patency without being greatly influenced by xenogenic immune reaction.

Comparison of Wind Vectors Derived from GK2A with Aeolus/ALADIN (위성기반 GK2A의 대기운동벡터와 Aeolus/ALADIN 바람 비교)

  • Shin, Hyemin;Ahn, Myoung-Hwan;KIM, Jisoo;Lee, Sihye;Lee, Byung-Il
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.6_1
    • /
    • pp.1631-1645
    • /
    • 2021
  • This research aims to provide the characteristics of the world's first active lidar sensor Atmospheric Laser Doppler Instrument (ALADIN) wind data and Geostationary Korea Multi Purpose Satellite 2A (GK2A) Atmospheric Motion Vector (AMV) data by comparing two wind data. As a result of comparing the data from September 2019 to August 1, 2020, The total number of collocated data for the AMV (using IR channel) and Mie channel ALADIN data is 177,681 which gives the Root Mean Square Error (RMSE) of 3.73 m/s and the correlation coefficient is 0.98. For a more detailed analysis, Comparison result considering altitude and latitude, the Normalized Root Mean Squared Error (NRMSE) is 0.2-0.3 at most latitude bands. However, the upper and middle layers in the lower latitudes and the lower layer in the southern hemispheric are larger than 0.4 at specific latitudes. These results are the same for the water vapor channel and the visible channel regardless of the season, and the channel-specific and seasonal characteristics do not appear prominently. Furthermore, as a result of analyzing the distribution of clouds in the latitude band with a large difference between the two wind data, Cirrus or cumulus clouds, which can lower the accuracy of height assignment of AMV, are distributed more than at other latitude bands. Accordingly, it is suggested that ALADIN wind data in the southern hemisphere and low latitude band, where the error of the AMV is large, can have a positive effect on the numerical forecast model.

Verification of Multi-point Displacement Response Measurement Algorithm Using Image Processing Technique (영상처리기법을 이용한 다중 변위응답 측정 알고리즘의 검증)

  • Kim, Sung-Wan;Kim, Nam-Sik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.3A
    • /
    • pp.297-307
    • /
    • 2010
  • Recently, maintenance engineering and technology for civil and building structures have begun to draw big attention and actually the number of structures that need to be evaluate on structural safety due to deterioration and performance degradation of structures are rapidly increasing. When stiffness is decreased because of deterioration of structures and member cracks, dynamic characteristics of structures would be changed. And it is important that the damaged areas and extent of the damage are correctly evaluated by analyzing dynamic characteristics from the actual behavior of a structure. In general, typical measurement instruments used for structure monitoring are dynamic instruments. Existing dynamic instruments are not easy to obtain reliable data when the cable connecting measurement sensors and device is long, and have uneconomical for 1 to 1 connection process between each sensor and instrument. Therefore, a method without attaching sensors to measure vibration at a long range is required. The representative applicable non-contact methods to measure the vibration of structures are laser doppler effect, a method using GPS, and image processing technique. The method using laser doppler effect shows relatively high accuracy but uneconomical while the method using GPS requires expensive equipment, and has its signal's own error and limited speed of sampling rate. But the method using image signal is simple and economical, and is proper to get vibration of inaccessible structures and dynamic characteristics. Image signals of camera instead of sensors had been recently used by many researchers. But the existing method, which records a point of a target attached on a structure and then measures vibration using image processing technique, could have relatively the limited objects of measurement. Therefore, this study conducted shaking table test and field load test to verify the validity of the method that can measure multi-point displacement responses of structures using image processing technique.

The Effect of Ginkgo Biloba Extract on the Fractionsted Radiation Therapy in C3H Mouse Fibrosarcoma (Ginkgo Biloba Extract가 C3H 마우스 섬유육종의 분할 방사선치료에 미치는 영향)

  • Kim, Jong-Hoon;Ha, Sung-Whan;Park, Charn-Il
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.155-164
    • /
    • 2002
  • Purpose : A ginkgo biloba extract (GBE) has been known as a hypoxic cell radiosensitizer. Its mechanisms of action are increase of the red blood cell deformability, decrease the blood viscosity, and decrease the hypoxic cell fraction in the tumor. The aims of this study were to estimate the effect of GBE on fractionated radiotherapy and to clarify the mechanism of action of the GBE by estimating the blood flow in tumor and normal muscle. Materials and Methods : Fibrosarcoma (FSall) growing in a C3H mouse leg muscle was used as the tumor model. When the tumor size reached 7 mm in diameter, the GBE was given intraperitoneally at 1 and 25 hours prior to irradiation. The tumor growth delay was measured according to the various doses of radiation (3, 6, 9, 12 Gy and 15 Gy) and to the fractionation (single and fractionated irradiation) with and without the GBE injection. The radiation dose to the tumor the response relationships and the enhancement ratio of the GBE were measured. In addition, the blood flow of a normal muscle and a tumor was compared by laser Doppler flowmetry according to the GBE treatment. Results : When the GBE was used with single fraction irradiation with doses ranging from 3 to 12 Gy, GBE increased the tumor growth delay significantly (p<0.05) and the enhancement ratio of the GBE was 1.16. In fractionated irradiation with 3 Gy per day, the relationships between the radiation dose (D) and the tumor growth delay (TGD) were TGD $(days)=0.26{\times}D$ (Gy)+0.13 in the radiation alone group, and the TGD $(days)=0.30{\times}D$ (Gy)+0.13 in the radiation with GBE group. As a result, the enhancement ratio was 1.19 ($95\%$ confidence interval; $1.13\~1.27$). Laser Doppler flowmetry was used to measure the blood flow. The mean blood flow was higher in the muscle (7.78 mL/100 g/min in tumor and the 10.15 mL/100 g/min in muscle, p=0.005) and the low blood flow fraction (less than 2 mL/100 g/min) was higher in the tumor $(0.5\%\;vs.\;5.2\%,\;p=0.005)$. The blood flow was not changed with the GBE in normal muscle, but was increased by $23.5\%$ ( p=0.0004) in the tumor. Conclusion : Based on these results, it can be concluded that the GBE enhanced the radiation effect significantly when used with fractionated radiotherapy as well as with single fraction irradiation. Furthermore, the GBE increased the blood flow of the tumor selectively.

Analysis of Loop-Rating Curve in a Gravel and Rock-bed Mountain Stream (자갈 및 암반 하상 산지하천의 고리형 수위-유량 관계 분석)

  • Kim, Dong-Su;Yang, Sung-Kee;Yu, Kwon-Kyu
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.9
    • /
    • pp.853-860
    • /
    • 2012
  • It is well-known that loop effect of the stage-discharge relationship is formulated based on many field observations especially for the sand rivers. Theoretical understandings of the loop effect for the sand rivers have been widely provided, based on the facts that it is driven by the flood wave propagation and bed form changes over the given flood period. However, very few theoretical studies or field observations associated with loop-rating curves in the gravel or rock-bed mountain streams have been attempted so far, due particularly to the difficulties in the accurate discharge measurement during the flood in such field conditions. The present paper aims to report a unique loop-rating curve measured at a gravel and rock-bed mountain stream based on the flood discharge observation acquired during the typhoon, Muifa that passed nearby Jeju Island in summer of 2011. As velocity instrumentation, a non-intrusive Surface Velocity Doppler Radar to be suitable for the flood discharge measurement was utilized, and discharges were consecutively measured for every hour. Interestingly, the authors found that the hysteresis of the loop-rating curve was adverse compared to the typical trend of the sand bed streams, which means that the discharge of the rising limb is smaller than the falling limb at the same stage. We carefully speculate that the adverse trend of the loop-rating curve in the gravel bed was caused by the bed resistance change that works differently from the sand bed case.

Myocardial atrophy in children with mitochondrial disease and Duchenne muscular dystrophy

  • Lee, Tae Ho;Eun, Lucy Youngmin;Choi, Jae Young;Kwon, Hye Eun;Lee, Young-Mock;Kim, Heung Dong;Kang, Seong-Woong
    • Clinical and Experimental Pediatrics
    • /
    • v.57 no.5
    • /
    • pp.232-239
    • /
    • 2014
  • Purpose: Mitochondrial disease (MD) and Duchenne muscular dystrophy (DMD) are often associated with cardiomyopathy, but the myocardial variability has not been isolated to a specific characteristic. We evaluated the left ventricular (LV) mass by echocardiography to identify the general distribution and functional changes of the myocardium in patients with MD or DMD. Methods: We retrospectively evaluated the echocardiographic data of 90 children with MD and 42 with DMD. Using two-dimensional echocardiography, including time-motion (M) mode and Doppler measurements, we estimated the LV mass, ratio of early to late mitral filling velocities (E/A), ratio of early mitral filling velocity to early diastolic mitral annular velocity (E/Ea), stroke volume, and cardiac output. A "z score" was generated using the lambda-mu-sigma method to standardize the LV mass with respect to body size. Results: The LV mass-for-height z scores were significantly below normal in children with MD ($-1.02{\pm}1.52$, P<0.001) or DMD ($-0.82{\pm}1.61$, P =0.002), as were the LV mass-for-lean body-mass z scores. The body mass index (BMI)-for-age z scores were far below normal and were directly proportional to the LV mass-for-height z scores in both patients with MD (R =0.377, P<0.001) and those with DMD (R =0.330, P=0.033). The LV mass-for-height z score correlated positively with the stroke volume index (R =0.462, P<0.001) and cardiac index (R =0.358, P<0.001). Conclusion: LV myocardial atrophy is present in patients with MD and those with DMD and may be closely associated with low BMI. The insufficient LV mass for body size might indicate deterioration of systolic function in these patients.

Algorithm and experimental verification of underwater acoustic communication based on passive time reversal mirror in multiuser environment (다중송신채널 환경에서 수동형 시역전에 기반한 수중음향통신 알고리즘 및 실험적 검증)

  • Eom, Min-Jeong;Oh, Sehyun;Kim, J.S.;Kim, Sea-Moon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.3
    • /
    • pp.167-174
    • /
    • 2016
  • Underwater communication is difficult to increase the communication capacity because the carrier frequency is lower than that of radio communications on land. This is limited to the bandwidth of the signal under the influence of the characteristics of an ocean medium. As the high transmission speed and large transmission capacity have become necessary in the limited frequency range, the studies on MIMO (Multiple Input Multiple Output) communication have been actively carried out. The performance of the MIMO communication is lower than that of the SIMO (Single Input Multiple Output) communication because cross-talk occurs due to multiusers along with inter symbol interference resulting from the channel characteristics such as delay spread and doppler spread. Although the adaptive equalizer considering multi-channels is used to mitigate the influence of the cross-talk, the algorithm is normally complicated. In this paper, time reversal mirror technique with the characteristic of a self-equalization will be applied to simplify the compensation algorithm and relieve the cross-talk in order to improve the communication performance when the signal transmitted from two channels is received over interference on one channel in the same time. In addition, the performance of the MIMO communication based on the time reversal mirror is verified using data from the SAVEX15(Shallow-water Acoustic Variability Experiment 2015) conducted at the northern area of East China Sea in May 2015.

Range Design of Pulse Repetition Frequency for Removal of SAR Residual Image (영상레이더 잔상 제거를 위한 펄스 반복 주파수의 범위 설계)

  • Kim, Kyeong-Rok;Heo, Min-Wook;Kim, Tu-Hwan;Ryu, Sang-Burm;Lee, Sang-Gyu;Lee, Hyeon-Cheol;Kim, Jae-Hyun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.11
    • /
    • pp.1653-1660
    • /
    • 2016
  • The synthetic aperture rardar (SAR) is an active sensor using microwaves. It transmits a microwave signal, called a chirp pulse, and receives the reflected signal in a moving platform such as satellite and unmanned aerial vehicle. Since this sensor uses microwaves that can penetrate the atmosphere, SAR generates the images regardless of light and weather conditions. However SAR operates on the moving platform, the Doppler shift and the side-looking observation method should be considered. In addtion, a residual image or ghost image can be occurred according to selection of the pulse repetition frequency (PRF). In this paper, a range design of the PRF for the L-band spaceborne SAR system is studied for prevention of SAR image distortion. And the system is studied for prevention of SAR image distortion. And the system parameter and the PRF are calibrated iteratively according to the proposed system design procedure and design constraints. The MATLAB based on SAR system simulator has been developed to verify the validity of calculated PRF. The developed simulator assumes that SAR sensor is operated by the PRF calculated from the design. The results of the simulator show that the targets in image has a valid peak to side-lobe ratio (PSLR) so that the PRF can be used for the spaceborne SAR sensor.

Experimental Effects of Aqua-Acupuncture of Carthami Flos on the Regional Cerebral Blood Flow and Mean Arterial Blood Pressure in Rats (홍화약침(紅花藥針)이 국소뇌혈류량(局所腦血流量) 및 평균혈압(平均血壓)에 미치는 실험적(實驗的) 영향(影響))

  • Kim, Sung-wook;Jeong, Hyun-woo;Wei, Tung-shuen;Cho, Myeng-rae;Yun, Yeo-choong
    • Journal of Acupuncture Research
    • /
    • v.21 no.2
    • /
    • pp.167-181
    • /
    • 2004
  • Objective : Carthami Flos has been used as a herb to promote blood circulation to remove blood stasis in oriental medicine for many centuries. To investigate treatment of cerebral vascular disease(CVA) by promoting blood circulation and removing blood stasis(活血化瘀法), we observed the experimental Effects of Aqua-Acupuncture of Carthami Flos on the Regional Cerebral Blood Flow and Mean Arterial Blood Pressure in Rats. Method : When aqua-acupuncture of Carthami Flos(ACF) was injected into LI4, Liv3, B23, B62, GV16, experimental effects of ACF on the regional cerebral blood flow(rCBF) and mean arterial blood pressure(MABP) is not known. Therefor, this study was designed to investigate the effects of ACF on the change of cerebral hemodynamics. The changes of rCBF and MABP were tested by Laser Doppler Flowmetry(LDF). Results : When ACF was injected into LI4, change of rCBF and MABP were decreased in a injected time-dependent manner. When ACF was injected into Liv3, change of rCBF and MABP were decreased in a injected time-dependent manner. When ACF was injected into B23, change of rCBF was significantly increased in a injected time-dependent manner, MABP did not change. When ACF was injected into B62, change of rCBF was increased in a injected time-dependent manner, change of MABP was significantly decreased after injection 60min. When ACF was injected into GV16, change of rCBF and MABP were similar to the change of normal. Conclusions : In conclusion, I suggested that ACF(LI4, Liv3) has an effect that depress the blood pressure & cerebral hemodynamic acceleration and ACF(B23, B62) has an anti-ischemic effect through the improvement of crebral hemodynamics.

  • PDF