• Title/Summary/Keyword: Fatigue

Search Result 9,580, Processing Time 0.039 seconds

DOF Correction of Heterogeneous Stereoscopic Cameras (이종 입체영상 카메라의 피사계심도 일치화)

  • Choi, Sung-In;Park, Soon-Yong
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.7
    • /
    • pp.169-179
    • /
    • 2014
  • In this paper, we propose a DOF (Depth of Field) correction technique by determining the values of the internal parameters of a 3-D camera which consists of stereoscopic cameras of different optical properties. If there is any difference in the size or the depth range of focused objects in the left and right stereoscopic images, it could cause visual fatigue to human viewers. The object size of in the stereoscopic image is corrected by the LUT of zoom lenses, and the forward and backward DOF are corrected by the object distance. Then the F-numbers are determined to adjust the optical properties of the camera for DOF correction. By applying the proposed technique to a main-sub type 3-D camera using a GUI-based DOF simulator, the DOF of the camera is automatically corrected.

Flexible Durability and Characteristics of ZnO, AZO and ITO Thin Films Grown by Aerosol Deposition Process (에어로졸 증착 공정으로 제조된 ZnO, AZO, ITO 박막의 특성과 유연 내구성)

  • Lee, Dong-Won;Cho, Myung-Yeon;Lee, Sang-Hun;Kim, Yong-Nam;Lee, Daeseok;Koo, Sang-Mo;Oh, Jong-Min
    • Journal of IKEEE
    • /
    • v.21 no.4
    • /
    • pp.404-407
    • /
    • 2017
  • We investigated the microstructure, electrical and optical characteristics of ZnO, AZO and ITO films using aerosol deposition process. As gas consumption increased, the electrical and optical characteristics of ZnO, AZO and ITO films were improved, and electrical and optical characteristics of ZnO, AZO and ITO films with a thickness of 400 nm were successfully fabricated on PET substrates at room temperature. The mechanical flexibility durability test shows that the ZnO films can withstand 5,000 cycles and AZO and ITO films occurs to crack in films with degradation of resistance and transmittance. Even though the AZO and ITO films shows slightly lower durability than the ZnO films, this is expected to improve performance of films through optimized processing condition and particle size control.

The Relationship between Perineal Demage in Delivery and Postpartum Depression (분만 시 회음부 손상과 산후 우울간의 관계)

  • Jang, Hyun-Jung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.4 no.1
    • /
    • pp.111-117
    • /
    • 2018
  • This study was conducted to examine the relationship between perineal demage, a physiological element that mothers experience immediately after delivery, and postpartum depression. The postpartum depression level of women after delivery was $6.67{\pm}4.34$ points at delivery, $7.41{\pm}4.77$ after 2 weeks, and $7.77{\pm}5.27$ after 6 weeks. The degree of mild postpartum depression increased to 26% after delivery, 33% after 2 weeks, and to 41.4 after 6 weeks. At 2 weeks and 6 weeks postpartum, the feeling of discomfort during walking or sitting caused by perineal incision had a direct correlation with postpartum depression. Therefore, in order to prevent postpartum depression, management of discomfort associated with the perineal incision should be given priority.

Study on the Development of Home Care Nursing Intervention Protocol for Stroke Patients (뇌졸중 환자의 가정간호중재 프로토콜 개발)

  • Yoo Ji-Soo
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.7 no.1
    • /
    • pp.122-136
    • /
    • 2000
  • Stroke patient needs rehabilitation after receiving an acute treatment in a hospital. When stroke patient gets involved in an early discharge program, home care nurse plays a pivotal role to make them to gain a full strength and to come back to his/her prior life before he/she is sick. In spite of the importance of home care nursing intervention protocol for home care nurses to perform home care nursing autonomously, home care nursing intervention protocol for stroke patient is rarely developed. Therefore this study was conducted to develop home care nursing protocol that is applicable for stroke patients in home care nursing area. 41 home care nursing charts for stroke patients registered in home care nursing agencies from December 1st 1994 to August 31st 1999 at Y hospitals in Seoul and Won-Ju city were analyzed. 44 home care nurses who were having over three years' experience on stroke patients were participated in this study as a user validity validation group. The results of this study are as follows. 1. 28 nursing diagnoses were selected on the basis of evaluation of nursing diagnoses of stroke patients presented in a previous literature and case studies on home care nursing. 2. 17 nursing diagnoses were classified through the frequency analysis of home care nursing charts for 41 stroke patients who had received home care nursing. The order of sequence was like these: impaired skin integrity, risk for infection, nutritional deficit, impaired physical mobility, constipation, knowledge deficit, ineffective airway clearance, anxiety in family members, risk for aspiration, self care deficit, altered urinary elimination, ineffective individual coping, social isolation, risk for injury, self-esteem disturbance, impaired verbal communication, fatigue of family caregiver. 3. Based on validation on expert and user validities, 44 nursing interventions which were above ICV=.80 were chosen. 4. Nursing intervention protocols which showed above ICV=.90 were developed and were like these; pressure ulcer care, position change, preventive care for circulatory dysfunction, tube care : catheter, vital sign monitor, constipation/impaction management, artificial airway management, suction of airway secretion, environmental management : safety, and fall prevention.

  • PDF

Static Performance Test for New Wave Dissipating Block Reinforced with FRP (FRP로 보강된 신형 소파블록의 정적 성능 실험)

  • Paik, In-Yeol;Oh, Young-Min
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.23 no.4
    • /
    • pp.285-291
    • /
    • 2011
  • In this study the mechanical performance of the new wave dissipating block is evaluated through experiment and numerical analysis. Also, by selecting adequate reinforcement, the improvement of the structural performance is examined. The reinforcement is designed by predicting the amount of tensile force and the location where the tensile stress develops in the new wave dissipating block through numerical analysis. The new wave dissipating block is reinforced with the ordinary steel bars and the fiber reinforced plastic(FRP) bars which have advantages in ocean environment in terms of corrosion and fatigue. The test result shows that the fracture resistance of the un-reinforced concrete block is 350 kN which is about 6.2 times that of the weight of the block. All the test blocks which are reinforced by either steel of FRP bars show strength capacity of over 900 kN which is the maximum load of the test equipment. Although the single reinforcement with larger-diameter bars has advantage in terms of construction convenience, it is recommended to use multiple number of smaller-diameter bars in order to reduce the crack width.

THE EFFECTS OF SPURE AND INVENTS ON THE CASTING ACCURACY AND POROSITY OF TI-NI CASTINGS

  • Cho Lee-Ra;Yi Yang-Jin;Park Chan-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.3
    • /
    • pp.342-350
    • /
    • 2003
  • Statement of problem. Titanium-Nickel alloy might be used in various prosthetic restorations since it has a unique property such as super-elasticity and high fatigue resistance. However, little is known about the casting ability of this alloy. Purpose. This in vitro study compared the casting accuracy and the porosity made with different investments and various sprue designs to ascertain what casting condition would be better for the fabrication of Ti-Ni cast restorations. Material and methods. A total of 70 Ti-Ni alloy crowns were made and divided into 7 groups of 10 copings on a metal master die. For measuring the effect of the sprue numbers, two groups with one and two 8-gauge sprues were compared. Moreover, the results of the conventional sprue and the double thickness sprues were compared. Three investments were used; carbon free phosphate bonded investment, titanium investment and gypsum bonded investment. The cast restorations were evaluated at 48 points on the entire circumferential margin with a stereomicroscope measuring in micrometers. Each crown was radiographically examined for casting defects and porosity. Data on casting accuracy were analyzed using two-way and Post hoc Scheffe's comparison to determine whether significant differences existed at the 95% confidence level. Student-Newman-Keuls test were performed to identify significant differences in the number of voids. Results. The double sprueing group and double thickness group had significantly less marginal discrepancy than the single sprueing group (P<.05 and P<.01, respectively). The castings with phosphate bonded investment showed the least marginal discrepancy and the smoothest surface. The castings invested in the gypsum bonded investment had the greatest gaps in margin and the largest failure rate. The double sprueing group and phosphate bonded investment group had significantly smaller void numbers and smaller void size than the other groups. Conclusion. Within the limitations of this in vitro study, the casting accuracy of the groups using thicker, double sprue design and the phosphate bonded investment was significantly superior. Moreover, void number and size were less than other groups.

Effect of abutment angulation in the retention and durability of three overdenture attachment systems: An in vitro study

  • Aroso, Carlos;Silva, Antonio Sergio;Ustrell, Raul;Mendes, Jose Manuel;Braga, Ana Cristina;Berastegui, Esther;Escuin, Tomas
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.1
    • /
    • pp.21-29
    • /
    • 2016
  • This in vitro study investigated and compared the durability and retention of three types of attachments. MATERIALS AND METHODS. Three commercially available attachments were investigated: $Clix^{(R)}$, Dalbo-$Plus^{(R)}$ and $Locator^{(R)}$. In total, 72 samples of these attachments were placed in the acrylic resin forms and subjected to mechanical testing (5400 cycles of insertion and removal) over the respective ball or Locator abutments immersed in artificial saliva at pH 7 and $37^{\circ}C$. The abutments were placed at angulations of $0^{\circ}$, $10^{\circ}$ and $20^{\circ}$. The retention force was recorded at the beginning and after 540, 1080, 2160, 3240, 4320 and 5400 insertion-removal cycles. RESULTS. The results revealed that there were significant differences in the average values of the insertion/removal force due to angulation ($F_{(2.48)}=343619$, P<.05) and the type of attachment ($F_{(7.48)}=23.220$, P<.05). CONCLUSION. Greater angulation of the abutments was found to influence the retention capacity of the attachments, and the fatigue test simulating 5 years of denture insertion and removal did not produce wear in the metal abutments.

Responses and Stresses of Structural Vibration of a Camshaft (캠축의 구조 진동 응답 및 응력)

  • Choi, Myung-Jin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.3
    • /
    • pp.208-213
    • /
    • 2013
  • To get vibration responses, a camshaft is modelled as an unbalanced multiple rotor bearing system. Because of complex geometry and complicated load conditions, the finite element method is used. After the finite element equation of the system is constructed, Newmark's method is used to get the vibration responses. Whirl vibration responses of a V-8 engine camshaft are estimated and compared with measured responses. After the fluctuating stresses are obtained, fatigue analysis is performed based upon the modified Goodman's equation. Stress concentration effects are considered. In the whirl vibration of camshafts, the bending effect is dominant, and the bending deformation is dependent upon the span length between the adjacent bearing journals. For high speeds, the fluctuations of excitation forces are large, and it is known that nonlinear time varying bearing coefficients should be used for analysis.

Parametric surface and properties defined on parallelogrammic domain

  • Fan, Shuqian;Zou, Jinsong;Shi, Mingquan
    • Journal of Computational Design and Engineering
    • /
    • v.1 no.1
    • /
    • pp.27-36
    • /
    • 2014
  • Similar to the essential components of many mechanical systems, the geometrical properties of the teeth of spiral bevel gears greatly influence the kinematic and dynamic behaviors of mechanical systems. Logarithmic spiral bevel gears show a unique advantage in transmission due to their constant spiral angle property. However, a mathematical model suitable for accurate digital modeling, differential geometrical characteristics, and related contact analysis methods for tooth surfaces have not been deeply investigated, since such gears are not convenient in traditional cutting manufacturing in the gear industry. Accurate mathematical modeling of the tooth surface geometry for logarithmic spiral bevel gears is developed in this study, based on the basic gearing kinematics and spherical involute geometry along with the tangent planes geometry; actually, the tooth surface is a parametric surface defined on a parallelogrammic domain. Equivalence proof of the tooth surface geometry is then given in order to greatly simplify the mathematical model. As major factors affecting the lubrication, surface fatigue, contact stress, wear, and manufacturability of gear teeth, the differential geometrical characteristics of the tooth surface are summarized using classical fundamental forms. By using the geometrical properties mentioned, manufacturability (and its limitation in logarithmic spiral bevel gears) is analyzed using precision forging and multiaxis freeform milling, rather than classical cradle-type machine tool based milling or hobbing. Geometry and manufacturability analysis results show that logarithmic spiral gears have many application advantages, but many urgent issues such as contact tooth analysis for precision plastic forming and multiaxis freeform milling also need to be solved in a further study.

Design Improvement on Wind Turbine Blade of Medium Scale HAWT by Considering IEC 1400-1 Specification (IEC1400-1 규격을 고려한 중형 수평축 풍력발전용 회전날개의 설계개선 연구)

  • 공창덕;정석훈;장병섭;방조혁
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.4 no.3
    • /
    • pp.29-37
    • /
    • 2000
  • Because the previous design procedure for the composite wind turbine blade structure using trial and error method takes long time, a improved design procedure by using the program based on classical laminate theory was proposed to reduce the inefficient element. According to the improved design procedure, limitation of strains, stresses and displacements specified by international standard specification IEC1400-1 for the composite wind turbine blade were applied to sizing the structural configuration by using the rule of mixture and the principal stress design technique with a simplified turbine blade. Structural safety for strength and buckling stability was confirmed by the developed analysis program based on the laminate theory to minimize the design procedure. After modifying the preliminary design result with additional structural components such as skin, foam sandwich and mounting joints, stresses, strains, displacements, natural frequency, buckling load and fatigue life were analyzed by the finite element method. Finally these results were confirmed by comparing with IEC1400-1 specification.

  • PDF