A Study on the Safety Distance of the Fuelling Facilities by the Radiation Heat in the Fire at the Gas Station (주유소 내 부대시설 화재발생시 복사열에 따른 주유설비 안전거리에 관한 연구)

  • Kim, Kisung;Lee, Sangwon;Song, Dongwoo
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.6
    • /
    • pp.7-13
    • /
    • 2021
  • Various research has been done on fires and explosions at gas stations at home and abroad. However, only studies of off-site damage in the event of fire at the gas station were conducted, and research on fire at the auxiliary facilities in the gas station was insufficient. The gas station is a place where anyone can easily access dangerous goods. As the risk of fire increases due to the recent increase of auxiliary facilities such as convenience stores and car repair shops in gas stations, it is important to detect the effects of fire on the main oil refinery in case of fire and to verify the validity of existing regulations. In this thesis, we conducted a study to find out the effect of radiation heat on the separation between fixed and fixed oil reactors in the event of fire at an auxiliary facility. Simulation was modelled using FDS 5.5.3 Version, and the size of the fire source was configured with 13 fire assessment devices and the heat emission rate per unit area was entered. Simulation shows that the separation distance of 2 m does not secure the safety of the gas pump in the event of fire at the auxiliary facilities, and radiation heat does not damage at the separation distance of at least 4 m. Accordingly, facilities that can block radiant heat in the event of fire at auxiliary facilities, and measures to limit the use of auxiliary facilities or to re-impose the separation between buildings and fixtures will be needed.

A Study on the Influence of Hotel's Architectural Attributes on Operating Revenue - Focused on Tourist Hotel in Seoul - (호텔의 건축적 속성이 운영 수익에 주는 영향에 관한 연구 - 서울지역 관광호텔을 중심으로 -)

  • Kim, Hyun-Kwang;Whang, Hee-Joon
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.8
    • /
    • pp.43-50
    • /
    • 2018
  • The purpose of this study is to analyze the effect of architectural attributes on operating revenue by concentrating on the facility side and to investigate how much individual architectural factors can affect operating revenue. The time range of this study is limited to 2015, and the spatial range is limited to a tourist hotel in Seoul that can be easily surveyed and verified. The analysis method is to confirm the significance and influence of each attribute through regression analysis. According to the results, The room part such as number of rooms or area showed a relatively low correlation with "revenue per available room (Rev.PAR)" than "average daily rate (ADR)", but showed a high correlation with non - architectural attributes such as auxiliary facilities and chain. This shows that factors that influence the operating profit of hotel are not the part of the room but the other factors such as the auxiliary facilities work more. In addition, the presence of spa and the number of auxiliary facilities in the hotel have a positive effect on the operating profit of the hotel due to the non - architectural attributes. This is expected to provide a new direction for future research in studying hotel facilities.

Reynolds number and scale effects on aerodynamic properties of streamlined bridge decks

  • Ma, Tingting;Feng, Chaotian
    • Wind and Structures
    • /
    • v.34 no.4
    • /
    • pp.355-369
    • /
    • 2022
  • Section model test, as the most commonly used method to evaluate the aerostatic and aeroelastic performances of long-span bridges, may be carried out under different conditions of incoming wind speed, geometric scale and wind tunnel facilities, which may lead to potential Reynolds number (Re) effect, model scaling effect and wind tunnel scale effect, respectively. The Re effect and scale effect on aerostatic force coefficients and aeroelastic characteristics of streamlined bridge decks were investigated via 1:100 and 1:60 scale section model tests. The influence of auxiliary facilities was further investigated by comparative tests between a bare deck section and the deck section with auxiliary facilities. The force measurement results over a Re region from about 1×105 to 4×105 indicate that the drag coefficients of both deck sections show obvious Re effect, while the pitching moment coefficients have weak Re dependence. The lift coefficients of the smaller scale models have more significant Re effect. Comparative tests of different scale models under the same Re number indicate that the static force coefficients have obvious scale effect, which is even more prominent than the Re effect. Additionally, the scale effect induced by lower model length to wind tunnel height ratio may produce static force coefficients with smaller absolute values, which may be less conservative for structural design. The results with respect to flutter stability indicate that the aerodynamic-damping-related flutter derivatives 𝘈*2 and 𝐴*1𝐻*3 have opposite scale effect, which makes the overall scale effect on critical flutter wind speed greatly weakened. The most significant scale effect on critical flutter wind speed occurs at +3° wind angle of attack, which makes the small-scale section models give conservative predictions.

A Modified Droop Control Method for Parallel Operation in Railway Auxiliary Power Supply Based on Virtual Impedance (철도 차량용 보조전원장치의 병렬 운전을 위한 가상 임피던스 기반의 드룹 제어)

  • An, Chang-Gyun;Choi, Bong-Yeon;Kang, Jin-Wook;Kang, Kyung-Min;Lee, Hoon;Won, Chung-Yeun
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.342-343
    • /
    • 2019
  • This paper explores the power distribution problem of parallel-connected inverter system which supplies auxiliary power for railway facilities. We propose a droop control method which facilities power distribution and restrain of voltage drop by tracking the average power control command by adjusting the virtual impedance. The performance of proposed droop method is verified by the PSIM simulation.

  • PDF

Practical Research on the Advanced Detention Pond for the Improvement of Water Quality of Agricultural Reservoir (농업용저수지의 수질개선을 위한 오염물질 침강지 조성 기법)

  • Pae, Yo Sop;Nam, Gui Sook
    • Journal of Wetlands Research
    • /
    • v.10 no.3
    • /
    • pp.79-86
    • /
    • 2008
  • To improve water quality for agricultural use, it is needed to introduce the natural and low-cost self-purification system. It is also necessary to develop the water purification facilities for more efficient and convenient design, construction, operation and management. This study aims to develop the practical facilities to improve water quality for agricultural use. The practical detention pond system, which uses artificial floating island and shield skirts with bio-media, enhanced removal efficiencies of SS, TN and TP more particularly than the detention pond using an auxiliary dam. The removal efficiencies SS, TN and TP for the practical detention pond were 55.7%, 61.0% and 55.9%, respectively. The facilities of the practical detention pond has a lot of disadvantages such as the low-cost and high efficiency as well as uncountable impacts regarding ecology and landscape. However, an auxiliary dam is recommended to be installed in shallow depth due to low efficiency.

  • PDF

Evaluation on the Dismantling Activities of the KRR-2 Radioisotope Production Facilities (연구로 2호기 동위원소생산시설 해체활동 평가)

  • 박승국;천은영;박진호
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.671-675
    • /
    • 2003
  • In accordance with the KRR-1 & 2 decommissioning project, the decontamination and dismantling activities of the KRR-2 auxiliary facilities, radioisotope production facilities, were completed from Aug 2001 to Dec 2002. The auxiliary facilities were composed of the concrete hot-cell, lead hot-cells and several laboratories for the radioisotope production. The dismantling objects are home hoods, experimental desks, sinks, and contaminated inner facilities. For the purpose of the safe decommissioning activity, the method statements and working procedures were set up. The manpower of the total 20,933 man-hour was required and several dismantling equipments were also. The maximum surface contamination is: 9.24 Bq/$\textrm{cm}^2$ in removable contamination and 350,000 cpm in fixed contamination. The total amount of 62.146 Ton was raised as dismantled waste with kinds of the concretes, wood, steels, etc. The collective dose was evaluated as 0.33 mam-mSv during this period.

  • PDF

A Study on the Characteristic of Sea Wave (불규칙파(不規則波)의 특성(特性)에 관한(關) 연구(硏究))

  • Choi, Han-Kuy;Yun, Kang-Hun
    • Journal of Industrial Technology
    • /
    • v.5
    • /
    • pp.59-64
    • /
    • 1985
  • The remarkable economic growth achived during 1960-1980 in Korea inevitablely demanded the expansion and maintenance of the harbors and their auxiliary seashore facilities. One of the most important elements in the basic besign for the expasion of a harbor and its auxiliary facilities is, of course, the proper determination of the design wave which reflects the major characteristics of the seashore under consideration. In this study, the parameters of significant waves for the industrial harbors on East Coast, Muck-Ho and Po-Hang, are first computed by means of computer programming using S.M.B and P.N.J methods, respectively. Then the design waves with the return periods of 5-200 years were estimated by frequency analysis of the significant waves. A comparison of the design waves with the observed wave data during the past 10 years made it possible to determine the optimum value of design wave at the two harbors. The important results of this study can be summarized as follows; 1) It seems appropriate to take the design wave hieghts with the return period of 50 years at Muck-Ho and Po-Hang as 6.9 and 5.8 meters respectively. 2) It was found that for the determination of design waves on East Coast of Korean Peninsula P.N.J method works better than S.M.B method in predicting the significant wave, and the Log-Normal distribution fits best to the wave data which were put to frequency analysis.

  • PDF

Optimal evacuation route guidance system using recreational forest 3D scan data (휴양림 3D 스캔 데이터를 통한 최적 대피로 안내 시스템)

  • Jung, Sanghun;Gwon, Eunhye;Son, Hoon;Kang, Soyoung;Jung, Heokyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.258-259
    • /
    • 2021
  • Forest lodge are divided into forest resources, auxiliary facilities, and users, and are constantly being used along with well-being culture. In addition, attention to the safety of users is also required, and this study aims to study how users evacuate within a short time (golden time) in situations of natural disasters that may occur in forests. In order to search for the current location of the user and find the best evacuation route, 3D scans of the entire forest lodge(forest resources, auxiliary facilities, etc.) are performed, and the optimal trajectory to the evacuation site is found through recognition of the current location. It is believed that it is possible to provide a quick evacuation guide through a mobile device with gps.

  • PDF

Reduction of the the Ground Surface Potential Gradients by Installing Auxiliary Grounding Grids (보조접지그리드의 시설에 의한 대지표면전위경도의 저감)

  • 이승칠;엄주홍;이복희;김효진
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.2
    • /
    • pp.121-129
    • /
    • 2002
  • The present paper describes a technique for installing an effective grounding grids, the major objective is forced on the experimental evaluation of the performance and characteristics with the arrangement and installation method for grounding grids consisting of the means to protect electric shock, electronics and computerized facilities against lightning, switching and ground fault surges. The study is oriented on two major areas: (1) the analysis of the ground surface potential gradient with the arrangement of grounding grids, (2) the control of the dangerous ground surface potential rise. The experiments wee carried out with the impulse currents as a function of the installation method or arrangement of grounding grids. An installation method of the inclined auxiliary grounding grid was proposed to overcome the drawbacks of equally spared grounding grids, i.e. an appropriate design concept far the installation of grounding grids was found out, It has been shown that the installation of the intwined auxiliary grounding grid can also result in a mere than 50% decrease in the maximum potential gradient on the ground surface and enhance the level of safety for persons and electronic equipments..