• Title/Summary/Keyword: silicone

Search Result 1,462, Processing Time 0.029 seconds

Self-inflicted Tongue Ulceration in a Patient with Tourette Syndrome: A Case Report (뚜렛 증후군 환자에서 자해로 인한 혀 손상 : 증례 보고)

  • Lee, Kkotnim;Kim, Miae;Hwang, Inkyung;Park, Jihyun;Mah, Yonjoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.43 no.3
    • /
    • pp.327-333
    • /
    • 2016
  • Tourette's syndrome is a chronic neuropsychiatric disorder characterized by the presence of vocal and multiple motor tics. Tics are defined as brief, intermittent, repetitive, unpredictable, purposeless, and stereotyped movements or sounds. Some patients experience physical pain from intense and complex tics. In addition, motor tics can result in self-injury which is a common feature of Tourette's syndrome. A 9-year-old boy was referred by the department of neuropsychiatry because of a severe tongue laceration. His parents reported that he had been biting his tongue irregularly for 2 months before referral and suffered from an intense burning sensation. The repeated biting resulted in ulcers on the tongue, which quickly worsened and led to progressive difficulty chewing and swallowing food. We offered to give him a two-piece removable appliance to limit tongue biting; it was made of soft silicone and fitted to both the maxillary and mandibular arches. As we emphasized that the device could help alleviate his pain, he agreed to accept it and adapted well. Just 3 weeks later, his tongue lesions had healed significantly.

Clinical Experience of Silicone Airway Stent in the Management of Benign Tracheobronchial Stenosis (양성 기도협착질환에서 실리콘 기도스텐트의 임상경험 - Dumon 스텐트와 Natural 스텐트의 비교 -)

  • Ryu, Yon Ju;Yu, Chang-Min;Choi, Jae Chul;Kwon, Yong Soo;Kim, Hojoong;Kim, Jhingook;Suh, Soo Won
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.1
    • /
    • pp.62-68
    • /
    • 2005
  • Background : The clinical results of a Natural stent in patients with a benign tracheobronchial stenosis were examined by comparing the clinical outcomes and complications of those patients who underwent Dumon and Natural stenting in the management of benign airway stenosis. Methods : The medical records of 94 patients (39 Dumon and 55 Natural stent) with a benign tracheobronchial stenosis were reviewed and analyzed. Results : Post-tuberculous stenosis was the leading indication for airway stenting (74%), which was followed by post-intubation stenosis (21%). After intervention, the dyspnea had improved among those patients who underwent Dumon (90%) and Natural (86%) stenting. After stabilizing the dyspnea, the stent could be successfully removed in half of the patients who underwent both Dumon (54%) and Natural (49%) stenting. During the 42 month follow-up period, the complication rate was similar in those patients who underwent Dumon and Natural stenting: migration (46% vs 53%), granulation tissue formation (36% vs 49%), mucostasis (21% vs 16%) and restenosis (51% vs 36%). Conclusion : The clinical results of Natural airway stent was similar to those of Dumon stent in the management of benign tracheobronchial stenosis.

Comparison on marginal fitness and mechanical properties of copings with zirconia block and CAM type (지르코니아 블록과 CAM 종류에 따른 코핑의 변연적합도와 기계적 특성 비교)

  • Chung, In-Sung;Jeon, Byung-Wook;Kim, Won-Young;Kang, Jae-Min
    • Journal of Technologic Dentistry
    • /
    • v.39 no.2
    • /
    • pp.75-82
    • /
    • 2017
  • Purpose: This study provided the basic data for selection the zirconia block and CAM by means of marginal fitness observations, flexural strength test and hardness test. Methods: Three dental zirconia blocks(ABCera, NaturaZ, ST98) and two dental milling machines(CAD/CAM MS, DWX-50) were used in this study. Metal abutment(diameter 10 mm, height 5 mm, inclined angle $3^{\circ}$ taper, 1 mm chamfer margin) was fabricated by Ti customized abutment, and then zirconia copings were fabricated for each ten specimens. Silicone replica technique was used to observe the marginal fitness of cross-sections with a stereomicroscope at ${\times}50$ magnification. The dental zirconia blocks was cut into 10 pieces each having a size of $25mm{\times}5mm{\times}1mm$, and fabricated according to the manufacturer's instructions, and flexural strength was measured using a universal testing machine. For hardness test, a micro Vickers hardness tester was used as it was in the flexural strength test. Statistical analysis was performed by one way ANOVA and post-test was performed by Scheffe test. Results: For marginal fitness of bucco-lingual axial, ZU group($59.7{\pm}10.3{\mu}m$) was the lowest, followed by RA, ZA, ZD, RD, RU. For marginal fitness of mesio-distal axial, ZU group($59.3{\pm}10.2{\mu}m$) was the lowest, followed by RA, ZA, RD, ZD, RU. One-way ANOVA showed statistically significant difference between groups(p<0.05). For flexural strength, ABCera block($718.0{\pm}57.2MPa$) was the highest, followed by NaturaZ, ST98. For hardness, ABCera block($1550.3{\pm}19.8Hv$) was the highest, followed by ST98, NaturaZ. There was no significant difference in flexural strength and hardness between blocks(p>0.05). Conclusion: Based on the results of this study, the type of dental zirconia block did influence the marginal fitness, and all dental zirconia blocks are expected to be suitable for clinical application. The highest flexural strength and hardness were ABCera block, and no statistically significant difference was observed.

SECONDARY RHINOPLASTY IN MID-FACIAL TRAUMA PATIENTS (중앙안면골 골절 환자에서의 이차 비성형술)

  • Jeong, Jong-Cheol;Kim, Keon-Jung;Lee, Jeong-Sam;Min, Heung-Ki;Choi, Jae-Sun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.18 no.4
    • /
    • pp.607-614
    • /
    • 1996
  • Nasal bone fracture is common in mid-facial trauma patients. In these patients, facial bone and nasal bone fracture are reducted at same time, but definite nasal reduction is difficulty in these patients because of nasotracheal intubation during general anesthesia and facial swelling in early facial trauma patients. If nasal packing and MMF are needed, there are difficult to maintain the reducted nasal bone because of some difficulty in airway maintenance after nasal packing and increasing the patient discomfort. So postoperative nasal deformity is more common in these combined patients. Secondary rhinoplasty is necessary in these patients who have deformed nasal bone, and there are many methods and materials for secondary rhinoplasty. But if primary nasal bone was reducted symmetrically, it is easy in secondary rhinoplasty. We present 7 cases of secondary rhinoplasty in mid-facial trauma patients who had combined nasal bone fracture. In these patients, primary nasal bone reduction carried with closed reduction method during primary facial bone reduction. About 6 months later, we performed secondary rhinoplasty with iliac bone and alloplastic materials. So we report these cases with literatures.

  • PDF

$H_{2}S$ Removal and $CO_{2}/CH_{4}$ Separation of Ternary Mixtures Using Polyimide Hollow Fiber Membrane (폴리이미드 중공사막을 이용한 혼합기체로부터 $H_{2}S$ 제거 및 $CO_{2}/CH_{4}$ 분리에 관한 연구)

  • Park, Bo-Ryoung;Kim, Dae-Hoon;Jo, Hang-Dae;Seo, Yong-Seog;Hwang, Taek-Sung;Lee, Hyung-Keun
    • Korean Chemical Engineering Research
    • /
    • v.49 no.2
    • /
    • pp.250-255
    • /
    • 2011
  • In this study, by using the polymeric membrane separation process, the $CO_{2}/CH_{4}$ separation and $H_{2}S$ removal from biogas were performed in order to $CH_{4}$ purification and enrichment for the fuel cell energy source application. Fibers were spun by dry/wet phase inversion method. The module was manufactured by fabricating fibers after surface coating with silicone elastomer. The scanning electron microscopy(SEM) studies showed that the produced fibers typically had an asymmetric structure; a dense top layer supported by a porous, sponge substructure. The permeance of $CO_{2}$ and $CO_{2}/CH_{4}$ selectivity increased with pressure and temperature. Mixture gas with increasing pressure and temperature, removal efficiency of the $CO_{2}$ and $H_{2}S$ were decreased while concentration of $CH_{4}$ was increased up to 100%. When retentate flow rate was increased with the decreasing of pressure and temperature the $CH_{4}$ recovery ratio in retentate side was increased while the $CH_{4}$ purity in retentate side was decreased.

Comparative Study on the Adsorptive Loss of Reduced Sulfur Compounds (RSC) by the Selection of Tubing Materials (튜빙의 종류에 따른 환원황화합물들의 흡착손실 비교 연구)

  • Kim Ki-Hyun;Ahn Ji-Won;Choi Ye-Jin
    • Journal of the Korean earth science society
    • /
    • v.26 no.7
    • /
    • pp.668-673
    • /
    • 2005
  • To collect or transfer samples of gaseous pollutants, various types of tubing are used. Hence, to analyze the uncertainties associated with the use of tubings, a series of comparative test were designed and conducted using the RSC standards with different concentration ranges. For the purpose of this study, we prepared tubings made of six different types of material which include: [1] silco-steel (S1), [2] stainless steel (S2), [3] silicone (S3), [4] PTFE Teflon (T1), [5] tygon (T2), and [6] brass (B). The patterns of RSC loss on to tubing walls, when compared on the basis of the least reactive material S1, exhibited that the extent of RSC loss varied dynamically. It was found that Teflon is highly stable. However, other materials tend to exhibit contrasting patterns of loss. S2 and B show significant loss of light RSC $(H_2S\;and\;CH_3SH)$, while S3 and T2 experience notable loss of heavy RSC (DMS and DMDS).

A STUDY ON THE TENSILE BOND STRENGTH BETWEEN VARIOUS RESIN TRAY MATERIALS AND RUBBER IMPRESSION MATERIALS (수종의 트레이 레진과 고무 인상재간의 인장 접착강도에 관한 연구)

  • Song Kyung-Won;Lim Ju-Hwan;Cho In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.4
    • /
    • pp.351-365
    • /
    • 2001
  • For accurate impression taking, accurate impression material, solid individual tray, and bond strength between impression materials and resin tray are important factors. The purpose of this study was to evaluate tensile bond strength of rubber impression materials to various tray resin materials. This study tested the time dependent tensile bond strength between commercial brands or poly ether, polysulfide, additional silicone impression materials and commercial brands of self curing tray resin. light activited tray resin when applying adhesive Resin specimens were made with 20mm in diameter, 2mm in thickness. 1 made total 360 specimens, 10 per each group and the tensile bond strength was measured by using the Instron($M100EC^{(R)}$, Mecmesin Co., England). The results were as follows ; Comparisons of various impression materials. 1. In case of Impregum $F^{(R)}$, the bond strength of tray resin was decreased in order of SR $Ivolen^{(R)}$, Ostron $100^{(R)}$ Instant tray $mix^{(R)}$, $Lightplast^{(R)}$. All groups excluding Ostron $100^{(R)}$, Instant tray $mix^{(R)}$ are significant difference (p<0.05). Drying time after applying adhesive, the tensile bond strength of tray resin was insignificantly decreased in order of 10 min drying time group. 1 min drying time group. 5 min drying time group. 2. In case of Permlastic $regular^{(R)}$ the bond strength of tray resin was insignificantly decreased in order of Ostron $100^{(R)}$. SR $Ivolen^{(R)}$, Instant tray $mix^{(R)}$ $Lightplast^{(R)}$. About drying time after applying adhesive, the tensile bond strength of tray resin was significantly decreased in order of 5 min drying time group, 10 min drying time group, 1 min drying time group(p<0.05). 3. In case of Exaflex $regular^{(R)}$. the bond strength of tray resin was decreased in order of $Lightplast^{(R)}$, SR $Ivolen^{(R)}$, Instant tray $mix^{(R)}$, Ostron $100^{(R)}$. $Lightplast^{(R)}$ was significant difference(p<0.05). About drying time after applying adhesive, the tensile bond strength of tray resin was decreased in order of 5 min drying time group, 10 min drying time group, 1 min drying time group(p<0.05). Especially 5 min ding time group was significant difference(p<0.05). According to the results of this study, we can see the greatest tensile bond strength when using Impregrm $F^{(R)}$ and Permlastic $regular^{(R)}$ with self curing tray resin, when using Exaflex $regular^{(R)}$ with light activated tray resin In my opinion, adhesive should be dried more than 5 min before impression taking to achieve the greatest tensile bond strength.

  • PDF

THE EFFECTS OF PORCELAIN PRIMERS ON THE BONDING OF COMPOSITE RESINS TO PORCELAIN (도재표면처리제가 복합레진과 도재와의 결합에 미치는 영향)

  • Back Myung-Ju;Park Ju-Mi;Bae Tae-Seong;Park Charn-Woon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.1
    • /
    • pp.55-64
    • /
    • 1992
  • This study investigated the effect of porcelain primer on bonding of coomposite resin to porcelain surface. In order to test the bond strength between porcelain and composite resin, porcelain cylinders were embedded in acrylic resin, and polished with 240grit silicone caqrbide paper. The specimens were divided into twelve groups. All specimens were treated with three porcelain primers and bonded with five composite resins. All test groups were stored in $37^{\circ}C$ distilled water for 48hours. Shear bond strengths were measured with Instron(Model 4201) at a cross-head speed of 1mm/min. The obtained results were as follows : 1. Scotchprime/Silux II group and BISCO Porcelain Primer/Bisfill group showed significant higher bond strengths than Clearfil Porcelain Primer/photo Clearfil Bright group(p<0.05). And there was no significant differences in bond strengths between Scotchprime/Silux II group and BISCO Porcelain Primer/Bisfill group(p>0.05). 2. When composite resins were used with Scotchprime, the bond strengths were decresed Silux II$(16.68{\pm}3.35MPa)$, Bisfil$(16.23{\pm}4.54MPa)$, Poly-Fill$(14.74{\pm}4.08MPa)$, Photo Clearfil Bright$(13.75{\pm}2.89MPa)$ and Pekalux$(14.74{\pm}4.08MPa)$ in order, but there was no statistical significance(p>0.05). 3. When composite resins were used with BISCO Porcelain Primer, the bond strength were decreased Bisfil$(16.17{\pm}1.60MPa)$, Silux II$(12.13{\pm}2.37MPa)$, Poly-Fill$(10.78{\pm}1.99MPa)$, Photo Cleafil Bright $(9.91{\pm}4.59MPa)$ and Pekalux$(7.36{\pm}2.16MPa)$ in order, but there was no statistical significance(p>0.05). 4. Silux II, Photo Clearfil Bright and Poly-Fill used with Scotchprime showed significant higher bond strengths than BISCO Porcelain Primer(p>0.05).

  • PDF

Occlusion Effect of Dentinal Tubules of the Desensitizing Dentifrices Marketed in Korea (국내 시판중인 지각과민 완화 치약의 상아세관 폐쇄효과)

  • Lee, Su-Young
    • Journal of dental hygiene science
    • /
    • v.11 no.5
    • /
    • pp.431-436
    • /
    • 2011
  • The aim of this study was to compare the effects of the short-term use of the desensitizing dentifrices marketed in Korea in vitro. Fifty human dentine specimens were wet ground with silicone carbide paper and etched with 6% citric acid for 90 seconds to allow complete opening of the dentinal tubule. Ten specimens from each group were brushed for 50 and 150 strokes with a V8 Cross Brushing Machine(Sabri Co., U. S. A). All the specimens were evaluated by SEM(${\times}3000$). The degree of occlusion of the dentinal tubules was quantified using an image analyzer. The results were analyzed by one-way ANOVA and Tukey's multiple comparisons using Window SPSS. The dentifrices containing nano-carbonate apatite, potassium nitrate and hydroxyapatite showed significantly higher occlusion effects than the other dentifrices after toothbrushing for 50 strokes(p<0.05). The Sensodyne freshmint$^{(R)}$dentifrice showed 34% fewer open tubular areas compared with the Sensodyne original$^{(R)}$dentifrice for 50 strokes. According to the short-term use of desensitizing dentifrices, the dentifrices containing nano-carbonate apatite, potassium nitrate and hydroxyapatite were most effective in occluding the dentinal tubules.

Elastic properties of addition silicone interocclusal recording materials (부가중합형 실리콘 교합인기재의 탄성 특성)

  • Lee, Young-Ok;Kim, Kyoung-Nam
    • Journal of Korean society of Dental Hygiene
    • /
    • v.12 no.3
    • /
    • pp.513-520
    • /
    • 2012
  • Objectives : In this study, contact angle and shore D hardness were measured, and a shark fin test was conducted after selecting five addition silicon(Blu-Mousse, BM; EXABITE II, EX; PERFECT, PF; Regisil$^{(R)}$ Rigid, RE; Silagum$^{(R)}$, SI) in order to figure out the properties of elastomeric interocclusal recording materials and reduce errors at interocclusal recording. 8) Methods : A contact angle was measured using a contact angle analyzer. After placing a drop of liquid on the surface of the specimens of interocclusal recording materials, a contact angle was photographed with a CCD camera on the equipment. In terms of a shark fin test, interocclusal recording materials were mixed for the time proposed by the manufacturer and inserted into the split ring of the Shark fin device. Twenty (20) seconds exactly, a metal rod was removed to make the materials slowly absorbed. Once they hardened, fin height was measured with a caliper after separating molds and trimming the specimens. The shore D hardness was measured with a shore D hardness tester(Model HPDSD, Hans Schmidt & Co. Gmbh, Germany) in sixty (60) minutes after fabricating specimens. In each experiment, five specimens, mean and standard deviation were calculated. A one-way ANOVA test was performed at the p>0.05 level of significance. In terms of correlation among the tests, Pearson correlation coefficient was estimated. For multiple comparison, Scheffe's test was carried out. Results : A contact angle was the highest in EX with $99.23^{\circ}$ (p<0.05) while the result of the shark fin test was the longest in RE with 5.45mm. SI was the lowest (0.27mm) with statistical significance. Among the interocclusal recording materials, significant difference was observed in terms of means (p<0.05). The shore D hardness was the highest in SI with 31.0 while RE was significantly low with 16.4 (p<0.05). Among the materials, statistically significant difference was observed in terms of means when compared to the rest materials (RE), BM, RE and SI (PF and EX) and the remaining materials (BM and SI) (p<0.05). In terms of correlations among the tests, a negative correlation occurred between shore D hardness and shark fin test(r=-0.823, p=0.000). Conclusions : According to the study above, it is necessary to understand the properties of interocclusal recording materials and consider contact angle, shark fin test and properties of shore D hardness to select appropriate materials.