저압방전등의 사용중에 발생하는 자계특성

Characteristics of Magnetic Field Generated by Operating Low Pressure Discharge Lamp

  • 이복희 (인하대학교 공과대학 전기공학과) ;
  • 전덕규 (인하대학교 공과대학 전기공학과) ;
  • 길경석 (인하대학교 공과대학 전기공학과) ;
  • 백용현 (인하대학교 공과대학 전기공학과)
  • 발행 : 1994.05.01

초록

This paper describes the developed sensor for measuring the time-varying magnetic fields and presents the characteristics of the magnetic fields and presents the characteristics of the magnetic field generated by lighting a fluorescent lamp. The frequency bandwidth of magnetic field measurement system is kknown as 40 Hz∼100 kHz by means of calibration experiment. The magnetic field waveform which originates from the various lighting systems was measured and the frequency components were analyzed by fast Fourier transformation technique. The magnetic field generated during the operation of the fluorescent lamp mainly includes the odd harmonics, and in the case\ulcorner of push button switch and high frequency starter types the fast transient component is occurred in an instant of lighting.

키워드