저압 터빈 마지막 단 동익 교체에 대한 고찰

Study on the replacement of last moving blade at lower pressure turbine

  • 구재량 (한국전력공사 전력연구원) ;
  • 이우광 (한국전력공사 전력연구원) ;
  • 고우식 (한국전력공사 전력연구원) ;
  • 김연환 (한국전력공사 전력연구원)
  • 발행 : 2003.04.23

초록

Vibration of turbine is concerned with array of last moving blade at lower pressure turbine. When last moving blade at lower pressure turbine was replaced, we must consider mass unbalance problems of blades. If mass unbalance happened at rotor, it is impossible to operate turbine. In this paper, we have how to minimize the mass unbalance problems of last moving blade at lower pressure turbine.

키워드