A test program was conducted on full-scale steel moment connections constructed using a T-stiffener. In the T-stiffener connection, the beam-to-column connection was reinforced with the horizontal and vertical element of the T-stiffener to resist moment under severe cyclic loads. A total of five specimens were tested in this study together with a concrete-filled tubular(CFT) column(${\sqsubset}-500{\times}500{\times}12$) and a steel beam($H-506{\times}201{\times}11{\times}19$). For the specimens, the T-stiffener was combined with RBS (also known as "Dog-bone") detail or Horizontal Element Hole(HEH) detail constructed to enhance deformation capacity. The test program showed excellent seismic performance for specimens constructed with an RBS or an HEH. except the specimens had brittle failure of VE. The test results also showed that the connections all developed maximum moments at the face of the column. Such moments were at least 15% and as much as 36% larger than the plastic moment capacity of the beam. based on the actual yield stress of the beam steel.

T-스티프너로 보강한 모멘트 접합부의 실대형 실험이 수행되었다. 극심한 반복하중하에서 접합부의 변형모멘트 저항능력을 높이기 위해서 T-스티프너의 수직 및 수평요소로 보강하였다. 본 연구에서는 모두 5개의 실험체에 대한 실험을 수행하였는데, 접합부를 구성함에 있어서 CFT기둥 (${\boxe}-500{\times}500{\times}12$)과 H형강보 ($H-506{\times}201{\times}11{\times}19$)를 사용하였다. 접합부의 변형능력을 향상시키기 위해 RBS 상세(Dog-bone)와 수평요소 홀(HEH) 상세를 조합했다. 실험결과 RBS와 HEH 상세를 가진 실험체는, VE가 취성파단한 실험체를 제외하면, 모두 우수한 내진성능을 보였다. 또한, 모든 접합부의 최대내력은, 보의 실제의 항복하중을 사용한 값으로 구한 전소성모멘트를 적어도 15%에서 많게는 36%정도로 상회하였다.

Keywords

References

  1. 콘크리트충전강관구조 설계 및 시공지침
  2. 한국강구조 학회논문집 v.13 no.6 T-스티프너보강 CFT 기둥-H형강보 실대형 접합부의 거동 김영주;강창훈;신경재;오영석;문태섭
  3. 한국강구조학회 학술발표대회 논문집 SS400 골 강판재와 전기로 H형강재의 제성질에 관한 통계적 연구 김종락;김성배;박양희;정웅기
  4. 콘크리트충전 강관구조 설계 및 시공기술 개발 연구
  5. 한국강구조학회 논문집 v.14 no.6 T-스티프너를 이용한 CFT기둥-H형강보 실대형 접합부의 비선형 해석 이승우;김영주;신경재;오영석;문태섭
  6. 한국강구조학회 논문집 v.14 no.1 리브로 보강된 철골 모멘트 접합부의 내진거동에 관한 실험적 연구 이철호;이재광;정종현;오명호;구은숙
  7. 日本建築學會構造係論文集 no.526 マイケルD エンゲルハ一ト, ノンスカラップ工法RBS工法による柱梁接合部の塑性變形能力 -改良形容接柱梁接合部の實大實驗-モの 1- 吹田啓-郞;田村匠;森田周平;中島正愛
  8. 日本建築學會構造系論文集 no.568 H形鋼梁の?形能力に柱梁接合部における?手效率が及ぼす影響の評價 岡田 健;松本由香;山田 哲
  9. AIJ Recommendations for design and construction of concrete filled steel tubular structures AIJ
  10. Proceedings of Pacific Structural Steel Conference (PSSC) Test of concrete-filled box column to H-beam connections Shin, K.J.;Oh, Y.S.;Moon, T.S.
  11. CFT column to H-beam connections with T-stiffeners, Report. No. STRESS-98-07, Seoul (South Korea): Advanced Structure Research Station (STRESS) Oh, Y.S.
  12. Engineering Structure v.23 no.9 Hystersis behavior of CFT column to H-beam connections with external T-stiffeners and penetrated elements Moon, T.S.;Oh, Y.S.;Shin, K.J.;Kang, C.H.
  13. Second International Symposium on Steel Structures CFT column to beam flange connections with external stiffeners Kang, C.H.;Chae, Y.S.;Shin, K.J.;Oh, Y.S.;Moon, T.S.
  14. Seismic provisions for structural steel buildings
  15. FEMA-355D. State of the art report on connection performance SAC Joint Venture
  16. Modification of existing welded steel moment frame connections for seismic resistance, Steel Design Guide Series 12 Gross, J.L.;Engelhardt, M.D.;Uang, C.M.;Kasai, K.;Iwankiw, N.R.
  17. International Journal of Steel Structure Design of Ductile Seismic Moment Connections, Increased Beam Section Method and Reduced Beam Section Method Chen, Sheng-Jin
  18. Engineering Journal Experimental investigation of dogbone moment connections Engelhardt, M.D.;Winneberger, T.;Zekany, A.J.;Potyraj, T.J.
  19. SAC protocol for fabrication, inspection, testing, and documentation of beam-column connection tests and other experimental specimens, Report No.SAC/BD-97-02 SAC
  20. IABSE symposium Predicted properties of Material under incremental cyclic loading Kato, B.;Akiyama, H.;Yamanouchi, Y.