Test-Bed Establishment Scheme for Terrestrial Laser Scanner' Performance Evaluation

지상레이저스캐너 성능평가를 위한 테스트베드 구축 방안

  • 이인수 (대한지적공사 지적연구원) ;
  • 차득기 (대한지적공사 지적연구원) ;
  • 김수정 (대한지적공사 지적연구원) ;
  • 김진 (대한지적공사 지적연구원)
  • Published : 2009.04.30

Abstract

3D terrestrial laser scanners record high precision three-dimensional coordinates of numerous points on an object surface in a short period of time, and is applied to a wide variety of fields including geodesy, and civil engineering, archaeology and architecture, and emergency service and defence, etc. However, most of terrestrial laser scanner utilized in homeland, were imported from foreign country, and also was not authorized formally as the surveying instrument. Therefore, standard test facility to calibrate and perform its evaluation in order to utilize it in a variety of fields is required. This study deals with the test facility of foreign countries for terrestrial laser scanner and suggest the establishment scheme of domestic test facility.

3차원 지상레이저스캐너는 짧은 시간에 대상물의 수많은 위치에 대한 고정도의 3차원 좌표를 얻을 수 있는 장비로서 측지분야를 포함하여 토목공학, 고고학 및 건축, 그리고 응급서비스 및 국방 등 다양한 분야에서 널리 응용되고 있다. 그러나 국내에서 이용되는 지상레이저스캐너 장비는 대부분 외국에서 수입되고 있으며, 현재 측량장비로서 공인되지 않은 상태이다. 따라서 지상레이저스캐너를 다양한 분야에서 활용하기 위해서는 장비 검정과 성능평가를 위한 실외 표준 테스트베드가 필요하다. 본 연구에서는 지상레이저스캐너의 테스트베드 구축과 관련하여 국외 사례를 고찰하여 이를 통해 국내 테스트베드 구축 방안을 제시하고자 한다.

Keywords

References

  1. 김정훈, 조춘만, 2008, 유비쿼터스 시대를 대비한 U-city 계획체계 정립 방안, The Journal of GIS Association of Korea, Vol, 16, No. 1, pp. 129-144.
  2. 이인수, 지상라이다를 이용한 건축물의 3차원 경계 추출, The Journal of GIS Association of Korea, Vol. 15, No. 1 pp. 53-65.
  3. Beraldin, J.-A,, Blais, F, El-Hakim, S, Cournoyer, L. and Picard, M., 2007 Traceable 3D Imaging Metrology: Evaluation of 3D Digitizing Techniques in a Dedicated Metrology Laboratory, published in at The 8th Conference on Optical 3-D Measurement Techniques. Zurich, Switzerland. July 9-12, 2007. NRC 49306.
  4. Beraldin, J.-A. 2004, "ntegration of laser scanning and close-range photogrammetry-The last decade and beyond," XXth Congress. International Society for Photogrammetry and Remote Sensing. Istanbul, Turkey. July 12-23,. Commission VII, pp. 972-983.
  5. Boehler, W., M. Bordas Vicent, A. Marbs, 2003, "Investigating Laser Scanner Accuracy," presented at the XIXth CIPA. Symposium at Antalya, Turkey, 30 Sept. 4 Oct.
  6. Cheok, G.S. and C. Stone, William, 2004, "Performance evaluation facility for LADARs," aerosense v2.
  7. Eric Martin, 2003, "Calibration verification for Lang Range Tripod-based Terrestrial Laser Scanner," proceeding of the LADAR Calibration Facility Workshop; Appendix H, June 12-13, National States Department of Commerce Technology Administration, U.S.A.
  8. Frank GIELSDORF, Andreas RIETDORF and Lothar GRUENDIG, 2004, A Concept for the Calibration of Terrestrial Laser Scanners, FIG Working Week 2004, Athens, Greece, May 22-27.
  9. Johansson, J. M, 2002, "Explorations into the Behavior of Three Different High-Resolution Ground-Based Laser Scanners in the Built Environment," Proc. of the CIPA WG6 Int. Workshop on Scanning for Cultural Heritage Recording, http://www.isprs.org/commission5/workshop.
  10. Marshall, S. J. and J. H. Gilby, 2001, "New Opportunities in Non-Contact 3D Measurement," Proceedings of National Measurement Conference, Harrogate, UK.
  11. Marshall, S.J, D. N. Whiteford, and R. Rixon, 2001, "Assessing the Performance of 3D Whole Body Imaging System," Proceedings of the 6th Numerisation 3D / Scanning 2001, Congress, Paris, France.
  12. Siebert, J.P. and S J Marshall, 2000, "Human body 3D imaging by speckle texture projection photogrammetry," Sensor Review 20 3, 218-226. https://doi.org/10.1108/02602280010372368