DOI QR코드

DOI QR Code

Performance Evaluation of the Hybrid Defrost Process in the Fin-Tube Evaporators of Refrigerators

하이브리드 제상 방식을 적용한 냉장고용 핀-관 열교환기의 제상 성능 평가

  • Lee, Su-Won (Refrigerator R&D Laboratory, LG Electronics) ;
  • Park, Yong-Joo (HA R&D Laboratory, LG Electronics) ;
  • Kweon, Lae-Un (Department of Mechanical Engineering, Pusan National University) ;
  • Jeong, Young-Man (Department of Mechanical Engineering, Pusan National University) ;
  • Lee, Jae-Keun (Department of Mechanical Engineering, Pusan National University)
  • Received : 2010.07.12
  • Accepted : 2010.11.17
  • Published : 2011.01.10

Abstract

The hybrid defrost process combined with hot-gas bypass defrost and electric heater defrost was experimentally evaluated about its defrost performance in the fin-tube evaporators of household refrigerators. Also the hybrid defrost process was compared with only electric heater defrost process. The defrost efficiency of the hybrid defrost process was shown two times higher than electric heater defrost process. The defrost time of the hybrid defrost process was shorten about 10%~50% than electric heater defrost process. Thermal shock after defrost process was decreased about 50% for the case of the hybrid defrost. It was found that energy consumption ratio of defrost process was reduced up to 7.4% compared with 22.4% of electric heater defrost at the condition of $25^{\circ}C$ ambient temperature.

Keywords

References

  1. Kang, G. J., Auh, J. H., Kim, M. J., Cho, K. Y., Choi, Y. H., Jung, D. S., Kook, S. U., and Park, K. W., 1996, Influence of thermal oscillation on quality of frozen foods stored in domestic refrigerator, Korean J. Food Sci. Technol., Vol. 28, No.4, pp. 624-631.
  2. Lee, K. S., Kim, G. W. and Jhee, S., 1998, An experimental study of behavior of defrosting on the fin tube heat exchanger, Journal of HVAC&R, Vol. 10, No.6, pp. 649-657.
  3. Bansal, P., Fothergill, D. and Fernandes, R., 2010, Thermal analysis of te defrost cycle in a domestic freezer, International Journal of Refrigeration, Vol. 33, pp. 589-599. https://doi.org/10.1016/j.ijrefrig.2009.11.012
  4. O'Neal, D. L. and Katipamula, S., 1991, Effect of short-tube orifice size on the performance of an air source heat pump during the reverse cycle defrost, International Journal of Refrigeration, Vol. 14, pp. 52-58. https://doi.org/10.1016/0140-7007(91)90022-9
  5. Krakow, K. I., Yang, L. and Lin, S., 1992, A model of hot-gas defrosting of evaporators, ASHRAE Transaction, Vol. 98, No.1, pp. 451-474.
  6. Hoffenbecker, N., Klein, S. A. and Reindl, D. T., 2005, Hot gas defrost model development and validation, International Journal of Refrigeration, Vol. 28, pp. 605-615. https://doi.org/10.1016/j.ijrefrig.2004.08.016
  7. Dopazo, J. A., Fernandez-Seara, J., Uhia, F. J. and Diz, R, 2010, Modelling and experimental validation of the hot-gas defrost process of an air-cooled evaporator, International Journal of Refrigeration, Vol. 33, pp. 829-839. https://doi.org/10.1016/j.ijrefrig.2009.12.027
  8. Choi, B. J. and Shin, J. M., 2002, The frost and defrost performances of fin-and-tube exchangers with different surface characteristics, Korean Journal of Air conditioning and Refrigeration Engineering, Vol. 14, No.6, pp. 525-531.
  9. KS C ISO 15502, 2007, Household refrigerating appliances-Characteristics and test methods, pp. 41-47.