DOI QR코드

DOI QR Code

Color stability of three dimensional-printed denture teeth exposed to various colorants

다양한 색소에 대한 3D 프린팅 인공치의 색 안정성

  • Koh, Eun-Sol (Division of Prosthodontics, Department of Dentistry, Asan Medical Center) ;
  • Cha, Hyun-Suk (Division of Prosthodontics, Department of Dentistry, Asan Medical Center, College of Medicine, University of Ulsan) ;
  • Kim, Tae-Hyung (Division of Restorative Sciences, Herman Ostow School of Dentistry of University of Southern California) ;
  • Ahn, Jin-Soo (Department of Dental Biomaterials Science and Dental Research Institute, School of Dentistry, Seoul National University) ;
  • Lee, Joo-Hee (Division of Prosthodontics, Department of Dentistry, Asan Medical Center, College of Medicine, University of Ulsan)
  • 고은솔 (서울아산병원 치과보철과) ;
  • 차현석 (울산대학교 의과대학 서울아산병원 치과보철학교실) ;
  • 김태형 (서던 캘리포니아 대학교 허만 오스토 치과대학 수복학교실) ;
  • 안진수 (서울대학교 치의학대학원 치과생체재료과학교실) ;
  • 이주희 (울산대학교 의과대학 서울아산병원 치과보철학교실)
  • Received : 2019.08.07
  • Accepted : 2019.10.22
  • Published : 2020.01.31

Abstract

Purpose: This study evaluated color stability of Dentca 3D-printed denture teeth, in comparison to color stabilities of four conventional types of denture teeth, upon being immersed in various colorants. Materials and methods: Four types of conventional prefabricated denture teeth (Surpass, GC, Artic 6, Heraeus Kulzer, Premium 6, Heraeus Kulzer, Preference, Candulor), 3D-printed denture teeth (Dentca); and Z250 (Filtek Z250, 3M ESPE) were prepared for testing. The samples were immersed in erythrosine 3%, coffee, cola, and distilled water (DW) at 37℃. Color change (ΔE) was measured by spectrophotometer before immersion and at 7, 14, and 21 days after immersion. One-way analysis of variance was performed along with Tukey's honestly significant difference multiple comparisons test (P<.05). Results: No great difference was observed between the color change of Dentca denture teeth and that of conventional denture teeth in most cases (P>.05). The color change of Dentca denture teeth immersed in erythrosine 3% was greater than that of Surpass (ΔE = 0.67 ± 0.25) after 1 week; Artic 6 (ΔE = 1.44 ± 0.38) and Premium 6 (ΔE = 1.69 ± 0.35) after 2 weeks; and Surpass (ΔE = 1.79 ± 0.49), Artic 6 (ΔE = 2.07 ± 0.21), Premium 6 (ΔE = 2.03 ± 0.75), and Preference (ΔE = 2.01 ± 0.75) after 3 weeks (P<.05). Conclusion: A color change was observed in Dentca denture teeth when immersed in some colorants; however, the maximum value of ΔE for Dentca denture teeth was within the clinically acceptable range.

목적: 본 연구는 다양한 색소에 침전된 Dentca 3D 프린팅 인공치의 색 안정성을 4가지 전통적인 인공치와 비교하여 평가하기 위함이다. 재료 및 방법: 4가지 전통적인 기성 인공치(Surpass, GC, Artic 6, Heraeus Kulzer, Premium 6, Heraeus Kulzer, Preference, Candulor), 3D 프린팅 인공치(Dentca), 그리고 Z250 (Filtek Z250, 3M ESPE)이 실험을 위하여 준비되었다. 시편은 37℃에서 에리스로신 3% 용액, 커피, 콜라, 그리고 증류수에 침전되었다. 색 변화량(ΔE)은 침전 전, 침전 7,14,21일 후에 분광광도계로 측정되었다. Tukey's honestly significant difference 다중 비교를 이용한 일원분산분석을 시행하였다(P < .05). 결과: 대부분의 케이스에서 Dentca 인공치와 전통적인 인공치 사이의 색 변화량은 큰 차이를 보이지 않았다 (P > .05). Dentca는 에리스로신 3% 용액에 침전된 1주 뒤의 Surpass (ΔE = 0.67 ± 0.25), 2주 뒤의 Artic 6 (ΔE = 1.44 ± 0.38), Premium 6 (ΔE = 1.69 ± 0.35), 그리고 3주 뒤의 Surpass (ΔE = 1.79 ± 0.49), Artic 6 (ΔE = 2.07 ± 0.21), Premium 6 (ΔE = 2.03 ± 0.75), Preference (ΔE = 2.01 ± 0.75)와 비교했을 때 더 많은 색 변화를 보였다 (P < .05). 결론: 일부 색소에 침전된 Dentca 인공치에서 색 변화가 관찰되었으나, ΔE의 최대값은 임상적으로 받아들일 수 있는 범위 내에서 관찰되었다.

Keywords

References

  1. Kurtulmus-Yilmaz S, Deniz ST. Evaluation of staining susceptibility of resin artificial teeth and stain removal efficacy of denture cleansers. Acta Odontol Scand 2014;72:811-8. https://doi.org/10.3109/00016357.2014.913195
  2. Piskin B, Sipahi C, Akin H. Effect of different chemical disinfectants on color stability of acrylic denture teeth. J Prosthodont 2014;23:476-83. https://doi.org/10.1111/jopr.12131
  3. Ruyter IE, Nilner K, Moller B. Color stability of dental composite resin materials for crown and bridge veneers. Dent Mater 1987;3:246-51. https://doi.org/10.1016/S0109-5641(87)80081-7
  4. Vichi A, Corciolani G, Davidson CL, Ferrari M. Color and opacity variations in three different resin-based composite products after UV aging. Inter Dent SA 2007;9:58-66.
  5. Gregorius WC, Kattadiyil MT, Goodacre CJ, Roggenkamp CL, Powers JM, Paravina RD. Effects of ageing and staining on color of acrylic resin denture teeth. J Dent 2012;40:e47-54. https://doi.org/10.1016/j.jdent.2012.09.009
  6. Koksal T, Dikbas I. Color stability of different denture teeth materials against various staining agents. Dent Mater J 2008;27:139-44. https://doi.org/10.4012/dmj.27.139
  7. Hersek N, Canay S, Uzun G, Yildiz F. Color stability of denture base acrylic resins in three food colorants. J Prosthet Dent 1999;81:375-9. https://doi.org/10.1016/S0022-3913(99)80001-8
  8. Barao VA, Ogawa ES, Moreno A, Mesquita MF, Wee AG, Assuncao WG. Long-term clinical evaluation of the color stability and stainability of acrylic resin denture teeth. J Prosthet Dent 2015;113:628-35. https://doi.org/10.1016/j.prosdent.2015.02.003
  9. Mousavi S, Narimani S, Hekmatfar S, Jafari K. Colour stability of various types of acrylic teeth exposed to coffee, tea and cola. J Dent Biomater 2016;3:335-40.
  10. Mutlu-Sagesen L, Ergun G, Ozkan Y, Bek B. Color stability of different denture teeth materials: an in vitro study. J Oral Sci 2001;43:193-205. https://doi.org/10.2334/josnusd.43.193
  11. Kattadiyil MT, Goodacre CJ, Baba NZ. CAD/CAM complete dentures: a review of two commercial fabrication systems. J Calif Dent Assoc 2013;41:407-16.
  12. Kim TH, Varjao F. 3D printed complete dentures. 1st ed. Illinois; Quintessence Publishing Co. Inc.; 2016. p. 141-9.
  13. van Noort R. The future of dental devices is digital. Dent Mater 2012;28:3-12. https://doi.org/10.1016/j.dental.2011.10.014
  14. Pereyra NM, Marano J, Subramanian G, Quek S, Leff D. Comparison of patient satisfaction in the fabrication of conventional dentures vs. DENTCA (CAD/CAM) dentures: A case report. J N J Dent Assoc 2015;86:26-33.
  15. Jeong YJ, Lim JH, Cho IH, Lim HS. Color stability of ceromers in three food colorants. J Korean Acad Prosthodont 2003;41:136-47.
  16. McGuire RG. Reporting of objective color measurements. HortScience 1992;27:1254-5. https://doi.org/10.21273/HORTSCI.27.12.1254
  17. Douglas RD, Steinhauer TJ, Wee AG. Intraoral determination of the tolerance of dentist for perceptibility and acceptability of shade mismatch. J Prosthet Dent 2007;97:200-8. https://doi.org/10.1016/j.prosdent.2007.02.012
  18. Guler AU, Yilmaz F, Kulunk T, Guler E, Kurt S. Effects of different drinks on stainability of resin composite provisional restorative materials. J Prosthet Dent 2005;94:118-24. https://doi.org/10.1016/j.prosdent.2005.05.004
  19. Gupta R, Parkash H, Shah N, Jain V. A spectrophotometric evaluation of color changes of various tooth colored veneering materials after exposure to commonly consumed beverages. J Indian Prosthodont Soc 2005;5:72-8. https://doi.org/10.4103/0972-4052.16873
  20. Um CM, Ruyter IE. Staining of resin-based veneering materials with coffee and tea. Quintessence Int 1991;22:377-86.
  21. Baba NZ, Goodacre CJ, Kattadiyil M. CAD/CAM removable prosthodontics. In: Masri R, Driscoll CF. Clinical applications of digital dental technology. Hoboken; John Wiley & Sohns, Inc.; 2015. p. 107-10.
  22. Baba NZ. Materials and processes for CAD/CAM complete denture fabrication. Curr Oral Health Rep 2016;3:203-8. https://doi.org/10.1007/s40496-016-0101-3
  23. Lin WS, Harris BT, Pellerito J, Morton D. Fabrication of an interim complete removable dental prosthesis with an inoffice digital light processing three-dimensional printer: A proof-of-concept technique. J Prosthet Dent 2018;120:331-4. https://doi.org/10.1016/j.prosdent.2017.12.027
  24. Lee JS, inventor; DENTCA Inc, assignee. Photo-curable resin compositions and method of using the same in three-dimensional printing for manufacturing artificial teeth and denture base. United States patent US2014/0167300A1. 2014 Aug 28.
  25. Kattadiyil MT, Al Helal A. An update on computer-engineered complete dentures: A systematic review on clinical outcomes. J Prosthet Dent 2017;117:478-85. https://doi.org/10.1016/j.prosdent.2016.08.017
  26. Park JH, Cho IH, Shin SY, Choi YS. The treatment of an edentulous patient with $DENTCA^{TM}$ CAD/CAM Denture. J Korean Acad Prosthodont 2015;53:19-25. https://doi.org/10.4047/jkap.2015.53.1.19
  27. Chen J, Ahmad R, Suenaga H, Li W, Sasaki K, Swain M, Li Q. Shape optimization for additive manufacturing of removable partial dentures-a new paradigm for prosthetic CAD/CAM. PLoS One 2015;10:e0132552. https://doi.org/10.1371/journal.pone.0132552
  28. Chung YJ, Park JM, Kim TH, Ahn JS, Cha HS, Lee JH. 3D printing of resin material for denture artificial teeth: Chipping and indirect tensile fracture resistance. Materials (Basel) 2018;11:1798. https://doi.org/10.3390/ma11101798