• Title/Summary/Keyword: 3-Fingers Type

Search Result 48, Processing Time 0.026 seconds

Analyzing Hand Geometry to Develop Safety Gloves for Dementia People (치매 환자용 안전 장갑 개발을 위한 손 형태 분석)

  • Sujoung Cha
    • Journal of Fashion Business
    • /
    • v.27 no.3
    • /
    • pp.19-34
    • /
    • 2023
  • The purpose of this study was to analyze the three-dimensional hand-related dimensions of elderly women aged 70 to 84 years and to characterize them to develop safety gloves for dementia patients. The 3D data from the 8th Human Size Survey of the National Institute of Standards and Technology, Size Korea, were analyzed using the SPSS 26.0 program. The straight thumb length was longer in elderly women aged 70-74 than in those aged 80-84. To analyze the hand type of elderly women, four factors were categorized: hand and finger horizontal factor, hand vertical factor, finger digit V thickness factor, and finger length factor. Elderly women's hand types were categorized as 'long hands and thin fingers', 'thick hands with long fingers', and 'short hands and thick little fingers'. Elderly women aged 70-74 years and 80-84 years were analyzed as having the most 'long hands and thin fingers' type, while older women aged 75-79 years were analyzed as having the most 'thick hands and long fingers' type. It is known that the fingers get thicker and the size of hands increase as age advances, but by the age 80, there is a change in the size of hands again. In future research, it would be worth expanding to other age groups to explore differences between age groups and to develop safety gloves for real-world dementia patients based on the hand types analyzed.

Highly-Sensitive Gate/Body-Tied MOSFET-Type Photodetector Using Multi-Finger Structure

  • Jang, Juneyoung;Choi, Pyung;Kim, Hyeon-June;Shin, Jang-Kyoo
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.3
    • /
    • pp.151-155
    • /
    • 2022
  • In this paper, we present a highly-sensitive gate/body-tied (GBT) metal-oxide semiconductor field-effect transistor (MOSFET)-type photodetector using multi-finger structure whose photocurrent increases in proportion to the number of fingers. The drain current that flows through a MOSFET using multi-finger structure is proportional to the number of fingers. This study intends to confirm that the photocurrent of a GBT MOSFET-type photodetector that uses the proposed multi-finger structure is larger than the photocurrent per unit area of the existing GBT MOSFET-type photodetectors. Analysis and measurement of a GBT MOSFET-type photodetector that utilizes a multi-finger structure confirmed that photocurrent increases in ratio to the number of fingers. In addition, the characteristics of the photocurrent in relation to the optical power were measured. In order to determine the influence of the incident the wavelength of light, the photocurrent was recorded as the incident the wavelength of light varied over a range of 405 to 980 nm. A highly-sensitive GBT MOSFET-type photodetector with multi-finger structure was designed and fabricated by using the Taiwan semiconductor manufacturing company (TSMC) complementary metal-oxide-semiconductor (CMOS) 0.18 um 1-poly 6-metal process and its characteristics have been measured.

A Study on the Motion Control of 3D Printed Fingers (3D 프린팅 손가락 모형의 동작 제어에 관한 연구)

  • Jung, Imjoo;Park, Ye-eun;Choi, Young-Rim;Kim, Jong-Wook;Lee, Sunhee
    • Fashion & Textile Research Journal
    • /
    • v.24 no.3
    • /
    • pp.333-345
    • /
    • 2022
  • This study developed and evaluated the motion control of 3D printed fingers applied to smart gloves. Four motions were programmed by assembling the module using the Arduino program: cylindrical grasping, spherical grasping, tip-to-tip pinch gripping, and three-jaw pinch gripping. Cap and re-entrant (RE) strip types were designed to model the finger. Two types of modeling were printed using filaments of thermoplastic elastomer (TPE) and thermoplastic polyurethane (TPU). The prepared samples were evaluated using three types of pens for cylidrical grasping, three types of balls for spherical grasping, and two types of cards for tip-to-tip pinch gripping and three-jaw pinch gripping. The motion control of fingers was connected using five servo motors to the number of each control board. Cylindrical and spherical grasping were moved by controlling the fingers at 180° and 150°, respectively. Pinch gripping was controlled using a tip-to-tip pinch motion controlled by the thumb at 30° and index-middle at 0° besides a three-jaw pinch motion controlled by the thumb-index finger-middle at 30°, 0°, and 0°, respectively. As a result of the functional evaluation, the TPE of 3D-printed fingers was more flexible than those of TPU. RE strip type of 3D-printed fingers was more suitable for the motion control of fingers than the 3D-printed finger.

Design of 3-Fingers Type Internal Antenna for GPS/PCS Handsets (GPS/PCS 단말기용 3-Finger형 내장형 안테나 설계)

  • Bang Sang-Won;Jung Byung-Woon;Lee Hak-Yong;Park Myun-Joo;Lee Byungje
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.1 s.92
    • /
    • pp.1-8
    • /
    • 2005
  • This paper proposes a new type of a dual-band internal antenna for GPS/PCS handsets. The antenna has three monopoles in different lengths, and this structure is referred as a 3-fingers type antenna in this paper. The antenna with low-profile structure is designed to use internal space of handset maximally. The fabrication and the measurement are accomplished by attaching the 3-finger type antenna to the inside of a commercial handset. We obtain gain of 1.97 dBi$\~$0.66 dBi in the GPS band, and -0.92 dBi$\~$1.02 dBi in the PCS band and almost omni-directional patterns at all bands.

Development of a Gripper for Robotic Transplanter and Evaluation of Its Transplanting Performance (육묘용 로봇이식기 그리퍼의 개발 및 이식 성능 평가)

  • 류관희;김기영;박정인
    • Journal of Biosystems Engineering
    • /
    • v.23 no.3
    • /
    • pp.271-276
    • /
    • 1998
  • A gripper mechanical design using a pneumatic system was developed to successfully grip, hold, and release a seedling plug for transplanting it. The gripper comprised of two air cylinders and shovel-type fingers. The gripper can grasp and hold a seedling by sliding the two fingers attached to the two separate air-cylinders, mounted at an angle of 15$^{\circ}$ When releasing a plug, retraction of the fingers gives a seedling little attachment to the gripper. To prevent seedling from attaching to the fingers, press-plates were attached to the end of the gipper. Transplanting performance of the developed gripper was tested with cucumber seedlings at different soil moisture contents. Overall transplanting performance of developed gipper was higher than the performance of the previously developed gripper. Best transplanting result was achieved at medium level of soil moisture content.

  • PDF

Arterialized Venous Free Flap at the Insufficient Vascular Recipient Bed in Finger Reconstruction (수지 재건시 불충분한 혈행상태의 수혜부에 시행한 동맥화 정맥 유리 피판술)

  • Lee, Young-Keun;Park, Ki-Tae;Lee, Jun-Mo;Park, Hyuk
    • Archives of Reconstructive Microsurgery
    • /
    • v.21 no.2
    • /
    • pp.131-136
    • /
    • 2012
  • Purpose: Arterialized venous flap is useful for reconstruction of the traumatic soft tissue defect in fingers, but insufficient circulation of the traumatic fingers makes surgeons annoying to use the flap. We have grafted flaps in 7 fingers with insufficient vascular bed hoping to expanded the category of the flap. Materials and Methods: Arterialized venous flap have transplanted in 7 fingers from March 2008 through February 2010 and followed up for 4 to 16 months(average 7.2 months). They were all male with a mean age at the time of surgery was 33. The main injury was crushing in 4 degloving, contact burn and saw injury was I respectively. Time interval from injury to flap transplantation was average 3.1. weeks(3 days to 6 weeks). Designed flap size ranges from $8cm{\times}3.5cm$to $4cm{\times}3cm$. Vessel type of flap was one artery with two veins were 5 cases and one artey with one vein 2. Flap type was cutaneous in 3, tendocutaneous 2, neurotendocutaneous 1 and neurocutaneous 1. The circulation state of recipient site was avascular in 2 cases, insufficiency 3 and tip avascular 2. Results: Arterialized venous flap was complete survived in 2 cases, partial necrosis(less than 10%) 3 and failed in 2. Conclusion: An arterialized venous free flap could be a useful procedure for reconstruction in soft tissue or combined defect of the finger despite an avascular or insufficient vascular beds if the recipient beds were free from infection.

  • PDF

The First Web Space Free Flap of the Foot to Reconstruct the Pulp of Fingers (수지 수질부 재건을 위한 족부의 제 1물갈퀴부 유리 피판술)

  • Kong, Byeong Seon;Kim, Yun Seok;Lee, Hyeong Seok;Jung, Dae Won;Kwak, Jae Yong;Lee, Hyun Suk
    • Archives of Reconstructive Microsurgery
    • /
    • v.21 no.2
    • /
    • pp.153-158
    • /
    • 2012
  • Purpose: The first web space of the foot has a similar thickness and skin texture of the pulp of the fingers. Moreover, it has a reliable blood vessel and sensory nerve. The purpose of this study was to evaluate the clinical results of the first web space free flap to reconstruct the pulp of fingers. Materials and Methods: Authors have performed 23 cases of first web space free flap to reconstruct the pulp defect of the fingers between June 2004 and May 2009. The age of the patients ranged from 20 years old to 55 years old. The size of the flap ranged from $1{\times}1.5cm$ to $8.5{\times}2.5cm$. The mean flap area was 5.4 cm2. In 4 cases, we elevated the flap including lateral aspect of the big toe and medial aspect of the second toe. And then we made an artificial syndactyly to reconstruct the pulps on two fingers at the same time. In all cases, we performed 1 digital artery and 1 dorsal vein anastomosis. Every donor site that had a small defect healed spontaneously without any additional operations to cover it. Results: Of this type of surgery 21 flaps (91.3%) survived, 2 flaps (8.7%) failed. There was no severe complication in the donor sites. There was no walking disturbance due to the skin defect of the donor site. The static 2 point discrimination in 11 cases that we could check ranged from 3 mm to 15 mm. Conclusion: The authors believe that the first web space free flap of the foot is a good option for the reconstruction of the pulp of the fingers and it has a minimal donor site morbidity.

  • PDF

Finger Counting Algorithm in the Hand with Stuck Fingers (붙어 있는 손가락을 가진 손에서 손가락 개수 알고리즘)

  • Oh, Jeong-su
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.10
    • /
    • pp.1892-1897
    • /
    • 2017
  • This paper proposes a finger counting algorithm for a hand with stuck fingers. The proposed algorithm is based on the fact that straight line type shadows are inevitably generated between fingers. It divides the hand region into the thumb region and the four fingers region for effective shadow detection, and generates an edge image in each region. Projection curves are generated by appling a line detection and a projection technique to each edge image, and the peaks of the curves are detected as candidates for finger shadows. And then peaks due to finger shadows are extracted from them and counted. In the finger counting experiment on hand images expressing various shapes with stuck fingers, the counting success rate is from 83.3% to 100% according to the number of fingers, and 93.1% on the whole. It also shows that if hand images are generated under controlled conditions, the failure cases can be sufficiently improved.

Refinements of Adipofascial flap for Small Defects of Fingers and Toes: Indication and Surgical Tips

  • Chung, Yoon-Kyu;Choi, Jin-Hee;Kim, Jiye;Chung, Seum
    • Archives of Reconstructive Microsurgery
    • /
    • v.25 no.2
    • /
    • pp.25-28
    • /
    • 2016
  • Purpose: Reconstruction of small defects of the dorsal fingers and toes is a challenging task. Although adipofascial flap is widely used for these areas, additional refinements are warranted. In this paper, we define the appropriate defect size in the finger and toes that can be treated with the adipofascial flap, refine its surgical indications and present a few surgical tips. Materials and Methods: Twelve patients with dorsal defects of the fingers and toes were treated with a random-type adipofascial turn-over flap and skin graft. If the defect area exceeded the size that could be covered by a conventional design, the flap base was designed in oblique or curvilinear fashion to lengthen the flap. For accurate defect coverage, the width of the flap base was designed in an asymmetrical shape depending on the defect configuration, varying the width from 0.3 to 1.0 cm, as opposed to the standard 0.5 to 1.0 cm width. Moreover, the lateral limit of the flap was defined as the lateral axial line. The size of the defect ranged from $3.0{\times}1.7cm$ to $1.5{\times}1.3cm$. Results: All flaps survived completely. Gliding function of the hand was well preserved and there was no evidence of tendon adhesion. Conclusion: The small defect in the dorsal finger and toe can be defined as less than one phalanx-length, measuring about $3.0{\times}2.0cm$ in size. If the defect exceeds this dimension, it is recommended that a different option be considered. We believe the adipofascial flap is an excellent option for treating small defects.

Miniatured Planar Bandpass Filter Using Coupled Metamaterial Resonators

  • Kim, Gi-Rae
    • Journal of information and communication convergence engineering
    • /
    • v.9 no.3
    • /
    • pp.256-259
    • /
    • 2011
  • In this article, new microstrip slow-wave bandpass filters using open loop resonator loaded with inter-digital capacitive fingers is proposed. The filter features not only compact in size, but also exhibits spurious stop-band rejection. Filters of this type with elliptic function and Chebyshev response are demonstrated. There is good agreement between experimental and full-wave electromagnetic (EM) simulation results.