• Title/Summary/Keyword: ultrasound

Search Result 3,247, Processing Time 0.039 seconds

Correlation between lateral abdominal, rectus femoris, and triceps brachii muscle thickness and endurance during prone bridge exercise in healthy young adults

  • Lee, Kyeong Bong;Kim, Jong Geun;Park, Han Gi;Kim, Ji Eun;Kim, Hye Sun;Lee, Wan Hee
    • Physical Therapy Rehabilitation Science
    • /
    • v.4 no.1
    • /
    • pp.11-16
    • /
    • 2015
  • Objective: Prone bridge exercise is one of the core strengthening exercise for improving abdominal, lower and upper extremity muscles. In addition, coactivation of the trunk muscles and extremities is important for treatment of low back pain. This study aimed to investigate the correlation between the thickness, cross-sectional area of the target muscle, and endurance during prone bridge exercise. Our hypothesis was that an increase in muscle thickness is positively related to the hold time for the static prone bridge exercise. Design: Cross-sectional study. Methods: Fourteen healthy university students (8 men and 6 women) voluntarily participated in the study at Sahmyook University. Hold time for the prone bridge with one and both legs was measured. The resting and contracted thickness of the lateral abdominal, rectus femoris, and triceps muscles was measured using rehabilitative ultrasound imaging. The correlation between muscle thickness and endurance for maintenance time was evaluated. Results: The prone bridge with both legs and the contraction thickness of the triceps muscle showed a positive correlation (r=0.692, p<0.05); the prone bridge with one leg and the contraction thickness of the internal oblique and transversus abdominis muscles showed a positive correlation (r=0.545, 0.574, p<0.05, 0.05, respectively). Conclusions: Endurance for the prone bridge exercise with a stable support surface is correlated with the contraction thickness of arm muscles; the prone bridge exercise with an unstable support surface is correlated with the contraction thickness of the deep abdominal muscles.

A Comparative Study on Heat Transfer Characteristics in Tissue Model with Application of Heating or Cooling Therapeutic Modalities (조직모델에서 냉.온치료기의 열전달 특성 비교 연구)

  • Kim, Yu Jong;Shin, Kyung Min;Kim, Eun Jung;Kim, Kyung Ho;Kim, Kap Sung;Lee, Seung Deok
    • Journal of Acupuncture Research
    • /
    • v.30 no.4
    • /
    • pp.125-138
    • /
    • 2013
  • Objectives : This study aimed to investigate temperature characteristics by heat transfer type of therapeutic modalities. Methods : We selected heating and cooling modalities that are frequently used in clinical by heat transfer type: conduction, convection, radiation, and conversion. We used ham as tissue model, and applied the modalities for 30 minutes. We measured real-time changed temperature($^{\circ}C$) of the surface, 2, 4, 6, 8, 10, 12, and 14 mm depth. Results : 1. In conduction-using hot pack, ice pack, and CryoStamp heating-cooling combination therapy unit($40^{\circ}C/{\sim}15^{\circ}C$), the surface temperature sharply rose close to equilibrium in first 5 minutes. 2. In convection-using smokeless moxa, temperature slowly rose to the maximum at 25-minute elapsed time. But in another convection-using CRAiS cryotherapy device, result was similar to that of conduction. 3. In radiation-using infrared lamp, result was similar to that of conduction, but not reached equilibrium during applying time. 4. In conversion-using ultrasound device, temperature was the highest at 6 mm depth, and not reached equilibrium during applying time. Conclusions : We could comprehend temperature characteristics and proper use of modalities by heat transfer type. It would be necessary to consider in vivo physical conditions in further studies.

Reliability and Validity of Ultrasound Imaging and sEMG Measurement to External Abdominal Oblique and Lumbar Multifidus Muscles (외복사근과 다열근에 대한 초음파 영상과 표면 근전도 측정방법의 신뢰도와 타당도)

  • Kim, Chang-Yong;Choi, Jong-Duk;Kim, Suhn-Yeop;Oh, Duck-Won;Kim, Jin-Kyung
    • Physical Therapy Korea
    • /
    • v.18 no.1
    • /
    • pp.37-46
    • /
    • 2011
  • The purpose of this study was to investigate intra-rater reliability and determine the validity of electromyography (EMG) measurements to represent muscle activity and ultrasonography (US) to represent muscle thickness during manual muscle testing (MMT) to external abdominal oblique (EO) and lumbar multifidus (MF). Twenty healthy subjects were recruited for this study and asked to perform MMT at differing levels. The subjects' muscle activity using EMG was measured by a ratio to maximum voluntary contraction (MVC) and root mean square (RMS) methods. The subjects' muscle thickness using US was measured by raw muscle thickness and change ratio of thickness to maximum (MVC) or resting condition. In three trials, measurements were performed on each subject by one examiner. The intra-rater reliability of measurements of EMG and US to EO and MF was calculated using intra-class coefficients. The intra-rater reliability of all measurements was excellent (ICC=.75~.98) in EMG and US. The conduct validity was calculated by one-way ANOVA with repeated measurements to compare whether the EMG and US measurements were different between MMT at different levels. There was only a significant difference between all grades at %MVC thickness measurement of US. These results suggest that a %MVC thickness measurement of US was a more sensitive and discriminate in all manual muscle testing grades. This information will be useful for the selection of US measurement and analysis methods in clinics.

Comparison of Abdominal Muscle Thickness Using Ultrasound Imaging During Bridging Exercises With a Sling and Ball in Healthy Young Adults

  • Moon, Young;Choi, Jong-duk
    • Physical Therapy Korea
    • /
    • v.27 no.1
    • /
    • pp.87-92
    • /
    • 2020
  • Background: Bridging exercises are used to enhance the functional stability of the lumbopelvic region in clinical settings. Although most of the studies on bridging exercises have compared the complete activation of the trunk muscles, some recent studies have examined the functional stability of the trunk and the lumbopelvic region and assessed the appropriate recruitment of the local and global muscles during different task levels. Objects: The purpose of this study was to investigate the changes in muscle thickness in the transverse abdominis (TrA), internal oblique (IO), and external oblique (EO) muscles during a common bridging exercise on an unstable surface and to determine whether these changes differ based on the surface used. Methods: Twenty-five healthy young adults (8 males, 17 females) were recruited. The subjects were randomly assigned to either the exercise progression with a sling bridge group or the ball bridging exercise progression group, each with three stages of increasing difficulty. Each position was measured three times with an ultrasonic diagnostic imaging system, and the mean values were recorded for analysis. Results: No significant differences were observed between the TrA, IO, or EO muscle thickness ratios between the sling and ball exercise groups (p > 0.05). There were also no significant differences in the EO muscle thickness ratios between the tasks irrespective of whether the sling or ball was used. However, the TrA and IO thickness ratios in both groups were significantly greater during stages 2 and 3 compared to stage 1. Conclusion: The results suggest that the use of slings and balls during bridging exercises is effective in activating the deep abdominal muscles.

Effect of Deep Breathing Exercise and Ankle Exercise on Blood Flow Velocity in the Femoral Vein (심호흡 운동과 발목관절 운동이 대퇴정맥의 혈류속도에 미치는 영향)

  • Jung, Do-Young;Kim, Young;Kwon, Oh-Yun
    • Physical Therapy Korea
    • /
    • v.9 no.2
    • /
    • pp.107-113
    • /
    • 2002
  • This study was conducted to determine the effects of deep breathing exercise and ankle exercise on blood flow velocity in the femoral vein. Sixteen healthy male students were recruited from Yonsei University, at Wonju. The blood flow velocities in the femoral vein were measured under three different conditions: resting, deep breathing, and ankle exercise. All subjects were given a 5-minute relaxing time in supine position prior to the study. Using a doppler ultrasound with a 8 MHz probe, the peak blood flow velocities were collected in a twenty-second-period at each condition. The subjects took a rest in between trials for the blood flow to return to its resting levels. The result showed a significant difference in peak blood flow velocities under those three conditions (p<.001). The peak blood flow velocity was highest in ankle exercise condition. The peak blood velocity was significantly higher in deep breathing condition compared with the resting condition. As a result, it is revealed that not only the muscular contractions but also the deep breathing exercises induced facilitating effects of venous return. Either of the exercise methods can be recommended to prevent blood stasis in patients with risk of deep vein thrombosis after cardiac or lower extremity surgery.

  • PDF

The Study of Voice and Data Transmission System using Underwater Ultrasound (수중초음파를 이용한 음성 및 데이터전송 시스템에 관한 연구)

  • Cho, Hyeok;Lee, Han;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.05a
    • /
    • pp.163-166
    • /
    • 2002
  • The underwater acoustic communication has been widely applied to various objects such as ocean exploration-development and military affairs. And recently for embodiment of the communication system that is installed in a submarine and underwater work system, many studies have been progressing. This scope of the main studies in the meantime. It made it possible for a diver and a scuba diver who arc difficult to notice the situation of the outside because of staying in the water to hear a sound through a small speaker by using a ultra sound transducer that a central frequency is 32KHz after modulation of a voice to give the information of the outside. Also in case of happening an emergency to a diver in the water, it made him/her ask for help to a person in the outside by pressing a key and send a letter data to a person in the outside by using a keyboard. Through this system, it is possible to send a voice or data between the underwater and the outside and it is available to a diver or skin scuba diver.

  • PDF

A Study on the Relationship Between State Anxiety and Maternal Fetal Attachment of Unmarried Mothers in a Welfare Center (보호시설 미혼모의 태아애착행위와 상태불안에 관한 연구)

  • Hwang, Ran-Hee
    • Women's Health Nursing
    • /
    • v.11 no.3
    • /
    • pp.218-224
    • /
    • 2005
  • Purpose: The Purpose of this study was to investigate the relationship between state anxiety and maternal fetal attachment of unmarried mothers in a welfare center. Methods: The subjects were 25 unmarried mothers in a welfare center. The data was collected through personal interviews using a questionnaire. The instruments used for this study were the modified Spielberger's state anxiety inventory and Cranley's Maternal-Fetal Attachment Scale. Data was analyzed descriptive statistics, mean, standard deviation, t-test and the pearson correlation coefficient with the SPSS computer program. Results: The age of the subjects ranged from 15 to 25, and their average age was 20.0. The mean score of state anxiety was 58.2. There was significant difference in the degree of maternal state anxiety between the group whose pregnancy was known by their family and the group whose pregnancy was hidden. The group whose pregnancy was known showed a low state anxiety score. There was a significant difference in the degree of maternal state anxiety by the gestational period. The group who were in the second and third gestational trimester showed lower state anxiety score than in the first trimester. The mean score of maternal-fetal attachment(MFA) was 64.9. There were significant differences in the degree of maternal fetal attachment, by an ultrasound scan experience. The most frequently practiced attachment item was "I think the fetus is able to feel(mean 3.8)". Unmarried mothers degree of state anxiety showed a negative correlation with the degree of maternal fetal attachment(r=-.25), but there was no significant difference between the two variables. Conclusions: The unmarried mothers made an effort in striving to reduce their high state anxiety and to enhance maternal fetal attachment. They also realize how to take care of their state anxiety.

  • PDF

Pregnancy Rate by Intrauterine Insemination (IUI) or Timed-Intercourse In Stimulated Cycles with Clomiphene Citrate and Gonadotropins (Clomiphene Citrate와 성선자극호르몬을 병합한 배란유도주기에서 성교와 인공수정에 의한 임신율의 비교)

  • Hong, Jeong-Eui;Lee, Ji-Sam
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.26 no.1
    • /
    • pp.31-41
    • /
    • 1999
  • To evaluate the effectiveness of intrauterine insemination (IUI) in the treatment of infertility, timed-intercourse and intrauterine insemination by husband in stimulated cycles with clomiphene citrate and gonadotropins were compared in a total of 105 cycles. Patients received 100mg of clomiphene citrate daily for 5 days starting on day 3 of the menstrual cycle followed by hMG or FSH. Doses of exogenous gonadotropins were adjusted by the follicular development and concentrations of serum estradiol $(E_2)$. More than 3 follicles reaching >16 mm were present in the ovary, 5,000 IU of hCG was administered intramusculary. Patients received a maximum of three intercourse or IUI cycles for the treatment. Severe male (<$10{\times}10^6$ motile sperm) or age factor (>39 y) patients were excluded in this study. Pregnancy was classified as clinical if a gestational sac or fetal cardiac activity was seen on ultrasound. The overall clinical pregnancy rates were 17.1% per cycle (18/105) and 21.2% per patient (18/85). The pregnancy rates (per cycle) were 17.5% (11/63) in intercourse and 16.7% (7/42) in IUI groups, respectively. IUI had no significant improvement in pregnancy rate compared with timed-intercourse. The multiple pregnancy rates were 11.1% (1 twin and 1 triplet). No patient developed ovarian hyperstimulation. Abortion rate was 28.6% (2/7) in IUI group only. The delivery and ongoing pregnancy rates were 15.2% per cycle (16/105) and 18.8% per patient (16/85). There were no differences in age, duration of infertility, follicle size and level of estradiol $(E_2)$ on the day of hCG injection in pregnant and non-pregnant groups. However, total doses of gonadotropins were higher in pregnant group than in non-pregnant group (p<0.01). Pregnancy rate was not affected by ovulatory status at the time of insemination. These results indicate that well timed-intercourse in stimulated cycles is as effective as IUI for infertile couples.

  • PDF

Assessment of follicular maturation by plasma estradiol levels and ultrasound in the normal and clomiphene-stimulated menstrual cycles (정상월경주기및 클로미펜을 이용한 배란유도 월경주기에서의 난포성장에 관한 연구)

  • Chang, Y.S.;Lee, J.Y.;Moon, S.Y.;Kim, J.K.;Lim, Y.T.;Han, K.S.
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.13 no.1
    • /
    • pp.67-75
    • /
    • 1986
  • Follicle monitoring in the normal and clomiphene·stimulated cycles were analyzed in the Seoul IVF and ET (In vitro fertilization and embryo transfer) program. Ovarian follicular diameters were measured by the real·time sector scanner and plasma estradiol levels were assayed by radioimmunoassay methods during periovulatory period. The maximum follicular sizes of the clomiphene-stimulated and normal cycles were 21.1+-3.4mm and 19.2+-0.8mm, respectively. The peak levels of plasma estradiol in the clomiphene-stimulated and normal cycles were 10538+-553.6ng/ml and 298.3+-39.6pg/ml, respectively. Daily growth rate of the follicular diameters of the clomiphene-stimulated and normal cycles were 2.1mm and 1.9mm, respectively. Mean follicular number of the clomiphene-simulated and normal cycles were 2.28+-1.12 and 1.12+-0.21, respectively. There was a good statistical correlation between the mean follicular diameters and the plasma estradiol levels in the normal ovulatory and c1omiphene-stimulated ovulatory menstrual cycles (p<0.05). Our data revealad that the mean follicular diameter and the plasma estradiol level prior to HCG administration in IVF and program should reach at the level of 17.8+-3.0mm and 949.4+-487.1 pg/ml, respectively.

  • PDF

Sequential Clomiphene Citrate and FSH compared to Clomiphene Citrate and hMG on Pregnancy Rate in Intrauterine Insemination Cycles (Clomiphene Citrate와 FSH 또는 Clomiphene Citrate와 hMG의 연속병합에 의한 배란유도주기에서 인공수정 후 임신율의 비교)

  • Jung, Goo-Sung;Hong, Ki-Eon;You, Seung-Hwan;Lee, Hyeon-Sook;Lee, Jong-In;Hur, Young-Mun;Jeon, Eun-Suk;Yoon, Jeong-Im;Hong, Jeong-Eui;Lee, Ji-Sam
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.26 no.3
    • /
    • pp.433-440
    • /
    • 1999
  • Objective: To evaluate the effectiveness of CC+FSH or CC+hMG in intrauterine insemination (IUI) cycles for the treatment of infertility. Method: Patients received daily 100 mg of clomiphene citrate (CC) for 5 days followed by hMG or FSH. A single IUI was performed at 36 h after hCG. Clinical pregnancy was classified if a gestational sac or fetal cardiac activity was seen on ultrasound. Results: The overall clinical pregnancy rate was 19.1% per cycle (17/89) and 21.5% per patient (17/79). More clinical pregnancies were recorded in CC+FSH (23.1%, 6/26) than CC+ hMG cycles (17.5%, 11/63), but this difference was not statistically significant. No differences were found in age, duration of infertility, follicle size, levels of estradiol ($E_2$) on the day of hCG injection and total motile sperm counts between pregnant and non-pregnant groups. However, more ampules of gonadotropins were used in pregnant group than non-pregnant group (p<0.05). Conclusion: Combination of CC and hMG may economically be more effective to induce ovulation for IUI compared to CC and FSH.

  • PDF