Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference (한국조명전기설비학회:학술대회논문집)
The Korean Institute of IIIuminating and Electrical Installation Engineers
- 기타
Domain
- Electricity/Electronics > Home/Electric Appliances
2007.05a
-
The Light brightness is to enhance the luminescence efficiency of phosphor including conductive material. In preparing the anode layer, phosphors mixed with conductive material prepared with pastes of polymer resin using by screen printing method. When the prepared anode layer bombarded by cold electron from emitter of cathode, it give rise to form the secondary electron from those of conductive materials such as ITO powder. Furthermore, we are expect to enhance the luminescence efficiency more than without conductive material.
-
The electron charging and degradation of anode phosphor layers are showed major problems in high electric field with anode electrode of field emission devices. An Al metal layer on the phosphor layer may get rid of these problems. This Al metal layer are formed with the roughness of phosphor surface layer without interlayer and cannot be given rise to enhance the luminance efficiency. In order to enhance the brightness, an anode layer need to be flated between phosphor layer and Al metal layer in anode electrode. After optimizing the anode phosphor layer, an anode layer with Al metal and inter layer increased the brightness and luminescence efficiency 1.5 times more than only phosphor layer in anode.
-
현재, 새로운 조명광원으로서 백색 LED가 기대되고 있으며, 이를 이용하는 조명이 확대되어 실용화 될 것으로 예상된다. LED 광원을 이용하여 조명기구를 제작하고 이것을 실내조명으로 사용할 때 조명기구에 의한 글레어가 편안함을 주는지 불편함을 주는지에 대한 평가가 요구된다. 실내 조명환경에 대한 불쾌글레어를 평가하기 위해 UGR(Unified Glare Rating)을 추천하고 있다. 그러나 균일한 글레어 광원의 평균휘도를 이용하여 계산된 종래의 불쾌글레어 평가법들은 불균일한 휘도를 갖는 LED 조명기구에 대해서는 적용하기 어렵게 될 것으로 판단된다. 그래서 UGR를 이용하였을 경우, 균일한 휘도를 갖는 조명기구와 불균일한 휘도를 갖는 조명기구에 대해서 어떠한 차이가 있는지 다음의 불쾌글레어의 주관평가 실험을 수행하였다. 평균휘도가 같고 최대 휘도와 최소 휘도가 다른 조명기구(균일한 휘도를 갖는 조명기구 1종과 불균일한 휘도를 갖는 조명기구 2종)를 글레어 광원으로 사용하였다. 입체각(
${\omega}$ )과 위치지수(Position Index)를 고정시키고 배경휘도($L_b$ )와 광원휘도($L_s$ )를 임의로 변화시켰다. 주어진 환경에서 피험자로 하여금 얼마나 편안하진 또는 불편한지에 대한 느낌을 값으로 평가하도록 하였다. 우선, UGR과 주관평가 사이에 차이가 나타났으며, 이는 동 서양에 따른 문화적 및 생리적 차이에 기인한다고 생각된다. 다음으로 균일한 휘도를 갖는 조명기구보다 불균일한 휘도를 갖는 LED 조명기구가 더 높은 값을 할당 받아 LED 조명기구가 불쾌감을 더 유발시키는 것으로 나타났다. 또한 LED 소자 간격에 따른 영향은 글레어 광원의 휘도가 높아질수록 크게 나타났으며, 배경휘도에 대해서도 광원의 휘도가 높아질수록 LED 소자 간격의 차이에 의한 영향이 나타났다. 따라서 UGR식은 균일한 휘도를 갖는 조명기구에 적용하기에는 적합하지만, 불균일한 휘도를 갖는 조명기구에 적용하기에는 부적합하다고 판단된다. -
In this paper we introduce the IP3003 which provides excellent Power Factor and Total Harmonic Distortion to the power system. It is developed by Interpion Semiconductor co. LTD. However, the efficiency of power factor correction system is very difficult to analyze mathematically. In this paper, we use the numerical simulation methods for analyzing PFC systems.
-
In this paper, a unified regenerative inverter and control algorithm are proposed in order to perform regenerative action and active power filter action. While the regenerative mode of traction, it works as regenerative inverter to reduce a excessive power of DC bus line and the powering mode of the traction, it works as active power filter to compensate ac current distortion, power factor, and voltage unbalance. In the paper, a regeneration inverter used PWM DC/AC inverter algorithm. And an active power filter used p-q theory. We are carrying out a mode analysis of DC traction system similar to actual system with MG-set and experimenting with prototype model. Through the simulation and experiment, we were proving the regeneration inverter operation which suggested in this paper.
-
This paper presents a experimental evidence of the generation of the earth potential and communication line noise from the electric railway. There is a critical measurement err in case of measuring the electrical power induced noise voltage and degree of cable balance in the field of earth potential generated. As a results, it has been found that the conventional cable has more noise immunity than shielded cable near the railway where the earth current flows through the sheath layer.
-
가용송전용량(ATC) 계산의 기준이 되는 총송전용량(TTC)은 일반적으로 열, 전압, 안정도 한계치에 의해 결정된다. 국내 계통의 송전선로 길이를 고려할 때 이 세 가지 한계치 중 열 정격은 TTC 결정에 가장 큰 비중을 차지하는 요소이다. 따라서 본 논문은 열 정격에 기상상태의 변화를 고려한 송전용량(DLR)의 개념을 도입하고 TTC를 결정하는 새로운 접근법을 제안한다. 이 방법은 기존 방법과 비교하여, 주변의 물리적 환경 변화에 따른 정확한 계산 결과를 도출함으로써 실시간 사용 가능한 용량의 평가가 가능토록 한다. 사례연구에서는 KEPCO의 PSS/E 데이터를 이용하여 기존의 방법과 제안하는 방법을 비교함으로써 제안하는 방법의 유용성을 보였다. DLR을 적용한 ATC평가의 방법은 전기적 안전 범위 내에서 ATC의 평가 결과를 증가시킴으로써, 선로 운영자에게 경제성 측면의 유용한 정보가 될 수 있을 것이다.
-
This study attempts to prove a superiority of slide-cover lighting. In order to solve these problems, cover materials with slide-type, blind cover should be prepared to make it easy to replace the light bulbs in a short time and to introduce a sense of decorative taste. Depending on an user's linking, slide-type cover can always change the indoor atmosphere by adjusting the light emitted from the lighting and meeting with the blind unit
-
Ballasts for HID lamp need a igniter to start the lamp with very high voltage over several kV. Electronic ballasts use various internal igniter in electronic circuits. The paper describe the simulation method for designing the igniter, which helps selecting the component properly by estimating operation voltage and current in circuits.
-
In recent, modeling methods for fluorescent lamp are developed well in both static and dynamic state. The models help reliable ballast to be developed in more fast time. This paper reviews the concept and method for well developed models, especially, circuit oriented models using PSpice.
-
전자식 안정기 회로구성은 EMI 필터부분과 고주파 공진인버터 그리고 안정기 출력을 제어하는 출력전압 및 주파수를 제어하는 부분으로 구성되며 half-bridge LCC 직렬공진회로가 주로 사용되고 있다. 고주파로 점등하기 때문에 음향공진 현상이 발생하여 아크의 떨림으로 인한 제반 요소들을 해결하기 위한 제어회로를 설계하여 해결한다. 본 논문에서는 메탈할라이드 램프와 전자식 안정기 회로의 시뮬레이션 데이터를 활용하여 전자식 안정기의 입력전압 변동시 출력을 일정하게 유지하는 정전력 회로 방식을 설계하여 보다 안정화된 400W급 전자식 안정기를 설계하고 시작품을 제작하여 얻은 결과를 검증하였다.
-
Light is a critical element for people to live and do creative activities in residential buildings. Especially, light in dinning room is the most important thing for psychological and emotional effects but people are living under the poor light environment. Most people even isn't well aware of good lighting environment. Also, the domestic lighting designers just follow the Korean Standards illuminance but it isn't appropriate to our cultural and social sides. This study investigates illuminance and color temperature of dining tables, and also analyzed the results of those in actual residential buildings.
-
실내조명의 조도 기준을 만족하는 LED Bulb를 개발하기 위하여 LED 개수를 선정하고, 실내 전반 조명에 적합한 배광을 실현하기 위한 렌즈설계를 하였다. 그리고 LED로부터 발산되는 열을 최적화하기 위한 방열설계를 행하여 주위온도
$50^{circ}C$ 이내에서 동작 가능하도록 하였다. 또한 시제품의 외함에 내장되어 질 수 있는 소형의 20[W]급 전원회로를 설계하고, 시제품을 직접 제작하였다. 시제품의 전기적, 광학적 성능은 CFL의 성능과 거의 동일하다. -
생활수준의 향상으로 인하여 조명 및 디스플레이 제품을 이용하여 건물 및 건축물에 대하여 장식을 하는 것이 일반화 되어가고 있다. 본 연구에서는 옥외 및 옥내에 사인물로 사용되어지고 있으며 설치가 간편한 디스플레이 조명기기인 LED Tile을 개발하여 옥내 및 옥외용 디스플레이 조명 시장의 시장성 확보하기 위하여, 광학설계를 통한 고휘도 LED의 선정 및 배치, 케이스 설계를 실시하고 LED모듈에 AC 220V 전원을 직접 인가할 수 있으며 효율이 높고 최적화된 구동회로를 설계하였다. 또한 One Chip 마이크로컨트롤러를 사용하여 RGB LED의 광색가변 및 점멸 제어회로를 설계하고, LED 모듈간에 2개의 제어선만을 연결하여 다양하고 다이나믹한 패턴 동작(점멸, 광색가변)이 가능하도록 펌웨어를 설계하였다. 그 결과 설계된 LED Tile은 전체 크기가
$D130{\times}W130{\times}H50mm$ 로 매우 컴팩트하고 LED 배치 및 광학설계를 통하여 최대광도 60cd를 실현하였으며, LED Tile의 동작개수에 관계없이 설치가 간단하며 10개 이상의 디스플레이 패턴 제어가 가능하였다. -
A Study on the Illumination Environment Design of Gallery Spaces on Bong-san culture street in DaeguThis study purports to survey on the illumination environment design in gallery. These gallery spaces need to improve individual illumination environments, in compliance with the recommended ratio of illumination intensity to brightness, and to create a new illumination design using a wide variety of illuminations.
-
Recently, there are rapid increases in golf population. People are enjoying play golf not only during the day but also at night as well. Although there are not many golf courses that offer night play, people inquire place where they can play night games due to their busy daily lives. To supply the demand in national golf courses night-lighting has been pushed ahead competitively, however there are few standards of lighting design in golf course. Because it is not clear that the standards of lighting in the world yet, this study aimed at presentation of standard of lighting design for planning golf course. Investigating the cases of golf course, this study suggested illumination standard of golf course to support comfortable visual-environment and measures to prevention glare for visitors.
-
A number of R, G and B LEDs for reference color temperature mixing ratio of RGB was determined by the theory of RGB mixing as a baseline. Once the number of LEDs was determined the objective color temperature from baseline has been achieved by the control the RGB duty ratio. And a practical prototype of 50W floodlighting adjusted by the above algorithm. The micro controller was developed with control algorithm for RGB duty ratio to obtain the objective color temperature. Detailed experiments to optimize algorithm of duty ratio and color temperature will be discussed in this paper as well.
-
In order to decrease the degradation of phosphor on anode, many kinds of methods try to do coating of phosphor powders and AI metal layer of anode phosphor, In case of direct coating of phosphor powder, thin and uniform coating process are difficult to cover homogeneous in the surface of phosphor powders and given rise to decrease the brightness, Anti-reflection-layer(ARC) with
$TiO_2$ ,$Al_2O_3$ ,$Y_2O_3$ showed 103[%] the enhancement of brightness in comparable with normal phosphor layer. -
Architecture design has need of daylight prediction to utilize daylight efficiently. But it is difficult to predict the exact value of available daylight in buildings. Using various lighting simulation software is not difficulty, but we can find different results under the same conditions. The purpose of this paper is to compare simulation values from various software such as Lumen-micro 2000, Lightscape 3.2, and Relux 2006. The same space and parameters of daylight(location of space and window, date, time, and skylight condition) are considered to conduct various simulation conditions.
-
Recently, since adjustment systems of various CCT(Correlated Color Temperature) are much developed, lighting environment of indoor has created by such various CCT lighting systems. If an indoor image of fixed CCT will quickly correct images of various CCT, lighting or interior designers can utilize it to persuade his or her clients in the indoor lighting planning process. Therefore, this paper presents fundamental data which are RGB data of seven color images for the correction of image by three different CCT.
-
Development of performance assessment model of lighting environment is promoting to improve indoor lighting Quality. Therefore, the extraction of performance assessment items of lighting environment must precede a model development. This paper analyzes the certification standards on the Green Building for the extraction\ of assessment items. The purpose of this paper is the extraction of assessment items as fundamental data for the development of performance assessment model of lighting environment.
-
Because of energy efficiency and environment-friendly characteristics, demands of white LED are being increased in various fields. White LED is being observed as next-generation light sources to alternate incandescent and fluorescent lamps so that the studies on white LED are being processed continuously. This study investigates technical developments and market movements of white LED to evaluate technical characteristics and to analyze performances data by comparing prototypes of white LEDs. And comparing efficiency of white LED with that of incandescent and fluorescent lamps, this study aimed at presentation of compatible standards for future LEDs.
-
본 논문에서는 콤팩트 메탈헬라이드 램프용 가로등 기구의 반사판에 대해 2차원 설계법을 기반으로 하는 3차원 설계법을 제시하고 포토피아 2.0의 반사판 설계 툴을 사용하여 150W 콤팩트 메탈헬라이드 램프용 도로 조명 기구의 반사판을 설계하였다.
-
본 논문은 겨울철 해상용 등명기의 유효광도 감소를 알아보기 위한 것이다. 적용환경의 특수성 때문에 태양전지와 축전지에 의존해야 하는 해상용 등명기의 경우, 일사량에 따라 그 성능에 크게 영향을 받을 수밖에 없으며, 특히 겨울철의 경우 일사량 부족으로 이런 문제점들이 대두되고 있다. 이에 기상청 자료에 근거하여, 겨울철 일사량 통계를 조사하고, 실험을 통해 겨울철 축전지 충/방전 특성 및 250mm 해상용 등명기의 유효광도 특성을 확인해 보았다. 또한 광달거리에 미치는 영향을 조사해 보았다.
-
We need two operation modes to obtain the complex hologram without bias and the conjugate image in the modified triangular interferometer(MTI). To solve the problem, we proposed the optimized MTI with one wave plate, which can obtain cosine and sine functions by the combination of one wave plate and one linear polarizer. In the extraction of phase term using the combination of polarization components, the phase error occurs, and we analyzed such potential phase errors in the optimized MTI.
-
경관조명은 야간관광자원 활성화를 통한 대외 경쟁력을 강화하고, 도시경쟁력을 향상시키며, 관광객들에게 도시 브랜드를 전달할 수 있는 수단으로 중요시되고 있다. 본 연구는 경관조명의 활성화에 따른 유지관리 비용을 절감할 수 있는 방안을 검토하기 위하여 국제 조명위원회(CIE)에서 제시하고 있는 조도 및 휘도 기준을 조사하였으며, 한강상 교량과 일산호수공원의 일부 지역에 대한 경관조명 설치현황 및 전력요금 사용실태를 조사하였다. 또한 '조명연출방법'과 '조명자재 선정에 의한 방법'에 따라 유지관리 비용 절감 현황을 검토하였으며, 각 회로를 세분화 하여 시간대별 제어가 가능하도록 하고, 조명연출에 적합한 조명 자재를 선정하여 적용함으로써 유지관리 비용이 절감됨을 알 수 있었다.
-
Hold-type display의 동화상 인식 원리를 이용하여 인간의 시각특성을 고려한 LCD의 동화상 퍼짐(blur) 노이즈 컴퓨터 시뮬레이터를 개발하였다. 그리고 이 시뮬레이터를 이용하여 통화상 퍼짐 노이즈 특성을 실험한 결과 화상의 이동속도가 빠를수록 퍼짐 노이즈가 증가하며 백라이트의 점등비가 낮을수록 노이즈가 저감된다는 것을 알았다. 이는 기존의 연구결과들과 잘 일치하는 것으로 이것으로부터 본 연구에서 개발한 시뮬레이터의 알고리듬이 타당하다고 할 수 있다.
-
단일 구동회로를 사용하여 패널전체를 동시에 방전시킬 수 있는 새로운 priming 방전기술을 고안하였다. 그리고 이 기술을 사용하여 1080개의 수평주사선수를 가지는 full-HDTV PDP를 고휘도로 구동할 수 있는 새로운 고속 구동방식을 제안하였다. 이 priming 방전기술을 사용하면 구동방식에 상관없이 priming 기간을 sustain 기간에 중첩시키고 ramp 파형을 가지는 priming pulse를 인가하는 것이 가능하다. 실험결과로부터 sustain 방전이 없는 경우에만 priming 방전이 일어났다. 그리고 sustain 방전은 priming 펄스의 영향을 거의 받지 않는다는 것이 확인되었다. 새로운 PDP 구동기술로
$0.7{\mu}s$ 의 address 펄스폭을 가지는 고속 address를 실현하였다. 그리고 40V의 넓은 address 동작마진을 얻었다. 이 기술들은 상용의 driver IC를 사용할 수 있도록 설계되어있으므로 상용화 가능성도 높다. -
유비쿼터스는 정보화 사회의 키워드가 되면서 새로운 정보통신 환경구축이 요구되고 있다. 국내 아파트에 있어 홈네트워크 설치가 증가하고 있으며 편리하고 다양한 기능들이 부가되고 있다. 세대내에서 조명, 난방, 가전제어와 보안 서비스의 제공은 물론 외부로부터 인터넷, 핸드폰으로 세대에 설치된 기기를 원격제어 감시하는 지능화로 발전되고 있다. 조명설비에 있어 첨단기술과 통합한 다양한 솔루션으로 세대의 일괄소등, 조광패턴제어, 무선리모콘, 유무선 원격제어가 활용되고 있으며 다양한 디자인의 조명기구와 제어시스템의 개발로 시간과 분위기에 적합한 조명을 연출하고 있다. 조명제어기술의 발전은 에너지 절감효과, 사전감지 기능으로 안전성 확보, 사용자의 편리성이 향상되어 미래 주거에 있어 쾌적하고 경제적인 조명환경 구현에 이바지하게 될 것이다.
-
BLUs are major component in LCD industry which occupies 90% or more of FPD market worldwide and BLU market is expected to be expanded continuously according to the trend of miniaturization, slimness, low power consumption and low weight. The larger the BLU market scale, the more important standardization of performance evaluation techniques to clearly prescribe the product specification. Currently the government is promoting the establishment of related laws and coincidence with international standards to cope with agreements such as WTO/TBT, but the nongovernmental standardization activities are not enough to be actualized. Furthermore, BLU related components such as CCFL, EEFL, inverter and reflector are already developed for localization to substitute imports with home products but collective standardization, national standardization, and international standardization are still not done. So, performance specifications and evaluation methods for normal fluorescent lamps or industrial lamps are being adopted and used as national standards and safety certification standards instead. Making these standards enables to prepare a chance to penetrate into global market and to promote world best products. Also, by making this collective standard, it provides chances to take part in international standardization activities, to protect domestic industries and technologies, to obtain the trend of advanced technologies, and to be predominant over other countries. That is to say, CCFL standardization helps raise 21st century national strategic technology policy and go ahead of globalization of core technologies.
-
Fluorescent induction lamps are assembly of a Low Pressure Mercury discharge vessel and an inductive power coupler. A vessel containing at least a Low Pressure Mercury vapor, which will be energized by means of the Inductive Coupler. The Ultra Violet radiation from the resulting discharge is converted by a layer of fluorescent material into visible light. The discharge vessel may have means of mechanical fixation to position it to the Inductive power coupler. The component to transform High Frequency electrical energy, by means of induction, in order to energize the Low Pressure Mercury in the discharge vessel. The component includes electrical connection. Fluorescent induction lamps don't have international standards yet. So we try to correspond Korea standards to international standards.
-
최근 들어 메탈핼라이드램프의 아크튜브에 석영관을 대신하여 세라믹(Ceratmic)을 이용하는 기술이 개발되었으며, 이는 탁월한 내열성 및 내식성으로 메탈헬라이드램프로 하여금 우수한 색온도 및 연색성 유지특성을 가질 수 있게 하였다. 본 논문는 국내의 차세대 세라믹 아크튜브 메탈핼라이드램프(Ceratmic Metal Halide lamp) 개발에 필요한 국외의 70W급 제품에 적용되는 세라믹 아크튜브에 대한 특성 분석을 통해 새로운 고효율, 장수명의 세라믹 메탈 핼라이드램프의 개발에 도움을 주고자 한다.
-
We introduce the IP3102 which is developed by Interpion Semiconductor co. LTD. for the CFL ballaster. The IP3102 has thermal compensation function. In this paper, we present the temperature compensation design technique and its implementation in the IP3102. The experimental results is also presented in this paper.
-
Hwang, Myung-Keun;Lee, Se-Hyun;Shin, Sang-Wuk;Cho, Mee-Ryoung;Yang, Seong-Yong;Jung, Kwan-Jin;Bae, Young-Jin 157
광속구에서 광원(light source)의 광속(luminous flux)을 측정할 때, 통상적인 측정환경의 변화는 보조램프(aux. lamp)를 사용하여 그 차이를 보정할 수 있다. 그러나 PLS(plasma lighting system)와 같이 표준광원과 시료광원의 위치가 크게 다를 경우에는 그에 따른 광속변화를 직접 측정하고 보정계수를 산출 반영하거나 시료광원의 측정위치와 동일한 위치에서 Calibration을 시행해야 할 것이다. 따라서 본 논문에서는 광속구에서의 기존 광원의 광학적 특성치를 통하여 새롭게 개발되는 광원류에 대한 부 표준램프를 제작 실험한 결과를 제시한 것이다. 광속구에서의 광특성은 센터와 사이드 측정방식에 의한 특성결과치를 기준으로 보정계수를 구하고 부 표준램프를 제작하였다. -
형광램프와 HID(high intensity discharge)램프는 수은(Hg)에 의해 빛을 방사한다. 산업환경의 변화속에서 침체기를 맞고 있는 국내 조명산업이 내부적으로는 친환경 조명제품 개발에 주력하고 외부적으로는 환경규제로 인한 피해를 최소화시킴과 동시에 적극적인 세계시장공략으로 고부가가치산업으로 성장할 수 있도록 조명분야의 환경규제 동향을 조사하여 조명산업 전반에 널리 홍보함으로써 국내 조명산업의 지속적인 경쟁력 및 성장가능성 확보에 목적을 두고 있다. 선진국을 중심으로 제도화되고 있는 환경규제(RoHS. WEEE 등)에 따른 문제점과 예상 영향(피해)도를 조사, 분석하여 시기적절한 효율적인 발전방안을 모색함으로써 국내 조명산업의 지속적인 경쟁력 및 성장가능성 확보를 위한 조명산업 발전방안 제시에 목적을 두고 있다.
-
최근에 정부의 "15/30 LED조명 보급정책"에 힘입어 개발된 8W급 조명용 LED광원의 CIE 색도좌표 (chromaticity coordinate)와 주파장(dominant wavelength)등을 측정 고찰 하였다. 적색(R), 녹색(G), 청색(B), 백색(W)순으로 주파장은 각각 620[nm], 531[nm], 465[nm], 579[nm]이고, 자극순도(excitation purity)는 0.98, 0.82, 0.97, 0.15이며, 휘도순도(colorimetric putity)는 45[%], 16[%], 279[%], 6[%]로 나타났다. Power LED의 최적배치 설계로서, 특히 백색 LED광원의 경우 백열전구(15 lm/W)에 비해 3배 이상의 높은 효율(47.71m/W)을 보였고, 배광측정에서는 78.7%의 효율로 나타났다. 현재 LED광원은 MR16이나 베이스 타입 등의 형태로 제작하여 스탠드, 복도등, 비상유도등, 침실용 등의 용도에 사용되고, 일부는 LED의 원형이나 면(flat)타입으로 가로등이나 투광등으로도 활용되고 있다. 따라서 이들에 대한 각각의 특성들을 제시해 둘 필요성인 인지되어 국내 최초로 개발된 R/G/B/W 8W급 LED광원에 대한 기본적인 광특성 결과를 얻었으며, 이중에서 HB 백색 LED램프의 색도좌표 값을 얻어 CIE표준광과의 색도좌표(x, y) 위치를 비교 검토할 수 가 있었다.
-
본 논문에서는 LED광원에서 현재 가장 많이 사용되는 MR과 PAR 타입의 램프를 측정 분석하였다. 최대광도 및 광속의 측정값을 비교 분석하였다. 그러나 MR 16 및 PAR 30의 경우 관련 KS 규격상에 광속에 대한 값을 명기하고 있지 않은데 이것은 램프 뒤쪽에 반사경(다이크로익 미러)이 부착되어 있어 가시광을 일정한 방향으로 집중시키는 투광 개념의 광원이므로 광속 측정의 의미가 필요하지 않아서 인 것으로 생각된다. LED광원의 경우 LED자체의 광 확산이 매우 광범위하고, 반사경의 영향을 적게 받고 있어 사이드 방식으로 측정된 상기의 광속값은 불확도 범위이내에 존재할 것이 확실시되므로 향후 LED관련 규격의 제안시 측정이 요구될 것으로 판단된다.
-
본 연구는 A체육대학교 옥내운동장 5곳을 선정하여 현재의 조명환경을 파악하고 수평면 및 수직면 조도를 측정하고 분석하였다. 고천장인 실내테니스장 배드민턴장, 핸드볼장과 저천장인 유도장과 탁구장을 선정하여 측정한 결과 평균조도는 실내테니스장 483[lx] 배드민턴장 272[lx], 핸드볼장 471[lx], 유도장 284[lx], 탁구장 370[lx]로 기준조도보다 상당히 낮게 측정되었다. 수직연 조도와 균제도도 권장치보다 낮게 나왔으나 연습경기장이므로 수평면조도를 충분히 보완한다면 연습하는 데는 큰 무리가 것으로 보인다. 전반적으로 조명환경이 열악하고 설비가 노후화되어 있으므로 시설보수 시 시뮬레이션을 활용하여 종목별 경기특성에 맞는 환경을 갖추도록 연구검토가 필요할 것으로 판단되었다.
-
국, 내외 택배시장은 과거 몇 개의 업체에서 독점했으나 현재는 대기업들과 수많은 중소기업들이 참여하고 있어 경쟁이 심화되고 있다. 우편물의 신속한 배송과 운송비용의 최소화는 매우 중요하며 이를 위하여 운송거리의 최단 거리화가 우선 필요하다. 본 논문은 전국의 주요 도시에 배치된 각 우편집중국을 기하학적으로 가장 짧게 연결하는 교환센터의 최적 위치를 찾는 방법을 제시한다. 배전시스템의 최적화, 전력계통의 routing 등에 이용되고 있는 Steiner tree 이론을 최단거리 우편물 운송망 구축에 적용하였다. Steiner tree로부터 선정된 위치에 교환센터를 설치할 경우, 운송비를 절감하여 경영수지를 개선할 뿐 아니라 신속한 배달을 최우선으로 하는 택배 시장에서 우위를 점할 수 있을 것으로 기대된다. Steiner tree 이론은 최단거리를 연결하는 전력소의 위치선정 등 전력계통에도 활용될 수 있을 것으로 사료된다.
-
The terminal voltage of a synchronous generator is maintained by the field current control of excitation system Generally AC/DC converter which is component of AVR(Automatic Voltage Regulator) system for excitation current control is connected to diode rectifier and DC/DC converter system In the case of diode rectifier system of phase controlled converter, AC/DC converter has low power factor and some low order harmonics in the line current. In this paper, two-stage three-phase PWM AC/DC converter is studied to solve these problems, The proposed method is verified by the computer simulations and experimental results in prototype generation system.
-
Energy distribution function for electrons in
$SF_6-Ar$ mixtures gas used by Simulation has been analysed over the E/N range 30${\sim}$ 300[Td] by a two term Boltzmann equation and by a Monte Carlo Simulation using a set of electron cross sections determined by other authors, experimentally the electron swarm parameters for 0.2[%] and 0.5[%]$SF_6-Ar$ mixtures were measured by time-of-flight (TOF) method. The results obtained from Boltzmann equation method and Monte Carlo simulation have been compared with present and previously obtained data and respective set of electron collision cross sections of the molecules. -
To apply the flux-lock type SFCL into power system, its current and voltage ratings are required to increase. Especially, in case of series connection of SFCLs, the countermeasure for simultaneous quenches must be considered. The structure, which each flux-lock type SFCL unit was wound in series on the same iron core, can induce the simultaneous quench of superconducting elements. Through the fault current limiting experiment for the suggested structure, it was confirmed that the even voltage burden among the superconducting elements comprising SFCLs could be made.
-
In recent years, equipment and network standards have been increasing in both number and complexity. Two standards that will soon be introduced to KOREA are the HV standards for assessing distorting and fluctuating loads, IEC 61000-3-6. Utility engineers, being under increasing time constraints, are turning more and more to software to quickly solve problems. This paper describes the methodology used to implement the above standards in Microsoft Excel in order to assist utility engineers to readily apply these standards in practical situations.
-
A method is proposed in this paper to determine the harmonic contributions of a customer at the point of common coupling. The method can quantify customer and utility responsibilities for limit violations caused by either harmonic source changes or harmonic impedance changes. It can be implemented in current power quality monitors and digital revenue meters. The method is comparison of measurement phase angles between harmonic voltage and current. The proposed method has been applied to the test system. The study results have indicated the accuracy of harmonic injection and emission for customer and utility.
-
본 논문에서는 열전발전소자를 이용하여 전력을 발생시키는 장치를 개발하기 위한 초기단계의 연구이다. 기존의 열전발전소자가 사용되는 곳은 폐열 및 지열 등 에너지 효율을 높이기 위한 간접 장치로 이용되었으나 본 연구에서는 메탄올의 열에너지를 직접적으로 이용하여 전력발생이 가능한 장치를 개발하기 위하여 메탄올 열에너지를 이용할 수 있는 구조 및 반응조건에 대해 연구하였다.
-
In this study accelerated aging test cycle and equipment was developed for aging test of polymer housed surge arresters under domestic weather condition In order to investigate aging characteristics of polymer surge arresters electrical and chemical analysis of the arresters which are used for accelerated aging test and outdoor exposure test were conducted. Through the analysis the capability of the proposed method was verified and characteristics data were presented for maintenance of domestic arresters. Based on these results long term reliability assessment method was proposed for polymer housed distribution surge arresters.
-
This paper presents a reduction method of penetrated electromagnetic fields through a narrow slot with resistive sheet in a planar conducting screen of infinite extent. When a plane wave is excited to the narrow slot, the aperture electric field is controlled by the parallel plates connected on the slot. The magnitude of penetrated electromagnetic fields through the narrow slot is controlled by the electric field distribution on the slot. The results show that the magnitude of the penetrated electromagnetic field can be effectively reduced by installing the resistive plates on the slot.
-
This paper presents a simple, robust excitation control system for synchronous generator using direct instantaneous voltage control(DIVC) method. The proposed DIVC excitation system can operate as high dynamics of power conversion system without any control gains such as Pill controller. And the transient overshoot of generator voltage can be suppressed with a simple time constant. For the continuous control of excitation system, the fast IGBT inverter system is used in this paper for exciter's field control. The proposed control scheme is verified by the computer simulations and experimental results in the prototype generation system.
-
It is focused on a methodology to establish a optimal inspection cycle of electrical facility of railroad Decision method of optimal inspection cycle is a process which establishes maintenance plan for facilities' immanent function as using reliability theory in operation term In order to ensure normal operation in a given condition, the decision method is logical for selecting effective maintenance plan to consider characteristic of system In estimation of failure rate, critical facility is selected firstly. After that, proper distribution function on each facility is decided to investigate distribution function for extraction of failure rate. Next, cost produced by the case that facility's failure is occurred is surveyed. Finally, maintenance method developed until now is investigated, before suitable model for the facility applying maintenance method is developed, and that maintenance decision is made. Therefore, this process is the method to find optimal inspection cycle for reasonable cost and effective reliability on facility.
-
Park, Hyoung-Min;Cho, Yong-Sun;Choi, Hyo-Sang;Oh, Geum-Kon;Jung, Soo-Bok;Lim, Sung-Hun;Choi, Myong-Ho 229
We investigated the quench characteristics of a superconducting element, two superconducting elements in order to increase the current capacity of flux lock type SFCL. The flux-lock type SFCL consisted of the transformer with a primary winding and a secondary winding connected in parallel, and the superconducting element was connected with secondary winding in series. The applied voltage at that time was 160${\sqrt{3}}$ . We found that the parallel connection between the superconducting elements increased the power capacity and let quench characteristics improve through their mutual linkage. -
A measurement technique in an industry site is basis technique which is bringing a ripple effect on an increasing productivity. Recently, a measurement request is increasing in the industry field as well as the variety field such as leisure, research. Thus, it is in point of time to secure an internal technique about measurement using a laser. In this paper, we prepare to develop the industrial precision laser distance measure device that is available measuring in several hundred meters[m]. In other words, we are planning to measure a wide distance using a laser diode that has long life and is compact, inexpensive. Through this research, we'll secure the pulse laser control technique, a signal processing, technique for distance calculation about a laser distance measurement system. And hereafter, we'll plan to commercialize a laser distance device using this research.
-
A large power fuel cell generation system needs a parallel operation of de-de boost converter. Therefore, this paper proposed parallel operation algorithms of de-de boost converters for the large scale fuel cell generation system of 250[kW] and the operating principle along with the control method in detail. This paper uses a maximum current sharing method as a parallel operation method and also the phase shift full bridge de-de converter as a de-de boost converter. Simulation and experimental results on two prototype converter modules of 500W show that the parallel operation method can be applied to the 250[kW] power converter.
-
It is increased electrical energy consumption with the development of intelligence society in office buildings and thus an energy conservation through efficient use of electricity became more important. This paper shows a reasonable design demand factor in office buildings, that was made by the systematic and statistical way considering actual conditions, such as investigated electric equipment capacity, peak power consumption, demand factor, etc., for 132 office buildings. In this dissertation, it is necessary to analyze the key features and general trend from the investigated data. It made an analysis of the feature parameters, such as average, standard deviation, median, maximum, minimun and thus it was carried linear and nonlinear regression analysis.
-
The tendency of lightning surge to propagate displays the difference for applicable power and equipment. However, looking into the subject equipment with the lightning surge, the lightning surge can be divided in between the two lines of power, between the power line and the ground, the power line and the PE conductor, between the neutral line and the ground and the like. In addition, in the event of the communication equipment, there exists the case of lightning surge entered from the power line in addition to the entry between the communication lines, the communication line and the ground. In this study, the tendency of propagation of lightning surge penetrated on to the subject equipment is analyzed through the empirical experiment in accordance with the ground method by using the independent ground, common ground, bypass arrester and others among the techniques for safety improvement in power lines.
-
Gas Discharge Tubes (GDTs) are widely used as surge protectors for commnuication applications due to their small internal capacitance. In these days, however, they are mostly used in combined configurations, because the activation voltage required to initiate the discharge process in the GDTs for sufficient amount of time can be large enough to damage surge-sensitive protected circuits. For GDTs with a considerably high initial over-voltage value, we should limit the peak voltage using a TVS or filter. As for ZnO varistors, even though their performance for voltage restriction is excellent, their applications in high-frequency commnuication circuits have been limited because of higher internal capacitance when compared to the GDTs. In order to develop a surge protector for commnuication applications by taking advantages of these two devices, we built a combination circuit that connects a GDT and a ZnO varistor along with a choke coil in common and differential modes. We describe how the applied SPDs operate in protection process steps with the actual data obtained from the residual voltage measurements at each step. The experiment results show that the surge voltage restriction with the choke coil is more effective in 100 [kHz] RingWave voltage than in lightning impulse voltage.
-
The Characteristics of Maximum Tolerable Voltage about Earth-Layer Structure in the Grounding SystemDuring the ground fault conditions, the flow of current to earth will produce potential gradients within and arround a substation. The common physiological effects of electric current on the body, stated in order of increasing current magnitude, are threshold perception, muscular contraction, unconsciousness, fabrillation of the heart. In this study, determined the tolerable voltage about earth-layered structure in the grounding system.
-
Many load modeling concepts have been proposed in the past. Efforts of load modeling may be summarized into three approaches ; the first one is to find an aggregation of various different load components scattered and distributed in an area. The second one is to find parameters to represent load from field tests, if any. And the third one is how to present the load of motor components could be represented. This paper proposes a system identification of combined load modeling to cover the second approach. In this paper, an improved method of system identification is suggested for the combined load model (dynamic and static load model) in which parameters of the equivalent induction motor. polynomial type load and their compositions.
-
The potential and step voltage distribution around low voltage joint-box cover were simulated with the variation of resistivity of water, depth of submerged water and point of leakage current. The potential distribution is very high gradient around low voltage joint-box, this condition is very dangerous states.
-
Lee, Bok-Hee;Choi, Jong-Hyuk;Park, Geon-Hun;Lee, Feng;Kim, Hoe-Gu;Lee, Kang-Soo;Ahn, Chang-Hwan 271
This paper presents the experimental results of underwater discharges in 25 mm point-plane gap caused by impulse voltage. Discharge phenomena were observed by digital cameras and recorded by oscilloscope. As a result, discharge patterns in positive and negative polarity have different shapes according to applied voltage amplitudes. The positive discharge is like root but the negative discharge is similar to bush. As the voltage is increased, the discharge routs are thick and have more branches. Also the time to breakdown is inversely proportional to voltage. -
The fault identification of electrical rotating machinery have been special interests due to one of important elements in the industrial production line. It is directly related with products quality and production costs. The sudden breakdown of a motor will affect to the shut down of the whole processes. Therefore, rotating machines are required to a periodic diagnosis and maintenance for improving its reliability and increasing their lifetime. The objective of this work is to develop the diagnosis system with current signals for the effective identification of healthy and faulty motors using the developed diagnosis algorithm, which consists of the feature calculation, feature extraction, and feature classification procedures.
-
This study described the designed and construction of uninterruptible power supply(UPS) system for large scale computer system KISTI's supercomputer system is serviced 24 hours and power supply should be achieved in stable voltage and frequency range. We analyzed the electric power usage for 4 years, and we found several optimal parameters for new design of UPS configuration.
-
In this paper, a new algorithm based on sensitivity method for alleviating overloads in power networks is presented to find the switching branches effectively. Preferentially the switching of shunt reactive devices such as shunt reactor and shunt capacitors is performed. If overloads are not eliminated, the ranking of switching branches is calculated according to the algorithm based on sensitivity method and the switching of the ranked branches is performed in the order of ranking until overloads are eliminated. In order to show the effects of this algorithm, it is applied to a small scale power system of IEEE 39-bus test system.
-
This paper preserts the characteristics of leakage currents flowing through 18 kV zinc oxide (ZnO) surge arrester under the mixed DC and AC voltages. The I-V curves of ZnO surge arrester were measured as a function of the voltage ratio K The I-V curves under the mixed DC and AC voltages lay between the pure DC and AC characteristics, and the cross-over phenomenon in I-V curves was observed at the low current region As a result, the increase of DC component to mixed voltages causes the increase of resistive component of total leakage current th ZnO surge arrester.
-
Biped robot requires that an energy source and a control part should be installed on the body to realize active system. So, we choose the DC motor having high torque in compact size in this study. In the DC motor serve system, we choose power amplifier with analog configuration, developed the module combined the controller and the driver. We applied this module to robot actuator and studied the response characteristics in an action and a return. Main controller with serve system, loading PIC micro controller, can be load on the robot with light weight.
-
This study developed a human robot master arm, which has a structure similar to the human arm, with the object of taking over human works. The robot arm was structured to reproduce human actions using three axes on each of the shoulder and the wrist based on mechanics, and the actuator of each axis adopted an ordinary DC motor. The servo system of the actuator is a one body type employing an amp for electric power, and it was designed to be small and lightweight for easy installation. We examined the posture control characteristics of the developed robot master arm in order to test its interlocking, continuous notions and reliability.
-
This paper is proposed an efficiency optimization control algorithm for a synchronous reluctance motor which minimizes the copper and iron losses. The design of the speed controller based on adaptive learning mechanism-fuzzy neural networks(ALM-FNN) controller that is implemented using adaptive, fuzzy control and neural networks. The control performance of the hybrid artificial intelligent controller is evaluated by analysis for various operating conditions. Analysis results are presented to show the validity of the proposed algorithm
-
In this paper, a new approach for the Synchronous Reluctance Motor control which ensures producing Maximum Torque per Ampere(MTPA) over the entire field weakening region is presented. In addition, This paper presents a speed sensorless control scheme of SynRM using artificial neural network. Also, by adjusting the base speed for the field weakening operation according to the flux level, the current and voltage limit, the smooth and precise transition into the field weakening operation can be achieved The proposed scheme is verified validity through simulation.
-
This paper is proposed a novel method to approximate the maximum power for a photovoltaic inverter system and tracking method. It is designed for power systems application and utilities. The proposed Maximum Power Point Tracking(MPPT) control has the advantage to provide a new simple way to approximate the optimal or rated voltage, the optimal or rated current and maximum power rating produced by a solar panel and the photovoltaic inverter. And this straightforward method will be named linear reoriented coordinates method(LRCM) with the advantage that Pmax and
$V_{op}$ can be approximated using the satre variable as the dynamic model without using complicate approximations or Taylor series. Furthermore tracking method is improved over 50% photovoltaic efficiency. This paper is proposed MPPT using LRMC and tracking method using weather condition of domestic moderate program technique. This paper is proposed the experimental results to verify the effectiveness of the new methods. -
This paper is proposed an efficiency optimization control algorithm for IPMSM which minimizes the copper and iron losses. The design of the speed controller based on adaptive fuzzy learning control-fuzzy neural networks(ABLC-FNN) controller that is implemented using adaptive, fuzzy control and neural networks. The control performance of the AFLC-FNN controller is evaluated by analysis for various operating conditions. Analysis results are presented to show the validity of the proposed algorithm
-
Traditional maintenance planning is based on a constant maintenance interval for equipment life. In order to consider economic aspect for tm based preventive maintenance, preventive maintenance is desirable to be scheduled by RCM(Reliability-Centered Maintenance) evaluation. The main objective of RCM is to reduce the maintenance cost, by focusing on the most important functions of the system and avoiding or removing maintenance actions that are not strictly necessary. So, Markov state model is utilized considering stochastic state in RCM In this paper, a Markov state model much can be used for scheduling and optimization of maintenance is presented. The deterioration process of system condition is modeled by the stepwise Markov model in detail. Also, because the system is not continuously monitored, the inspection is considered. In case study, simulation results about RCM will be shown using the real historical data of combustion turbine generating unit in Korean power systems.
-
본 연구는 출력특성의 안정성과 정밀성이 우수한 광전류센서의 개발을 위하여 센싱부의 온도변화에 따른 출력신호를 검토하고, 온도변화에 따른 출력특성이 안정된 센싱부를 적용하여 출력특성을 연구하였다. 기존 광전류센서에서 중요시스템인 센싱부의 광섬유의 온도특성과 Verdet 상수의 온도의존도에 따라 출력신호가 불안정하다. 이러한 광전류센서의 온도변화에 따른 오차를 개선하기 위해 센싱부에 대한 온도특성을 분석하고, 온도변화에 내구성이 뛰어난 소재를 적용함으로써 센싱부의 안정된 출력특성을 가지는 광전류센서를 개발하고자한다.
-
본 논문에서는 공동주택에서 운전되고 있는 승강기의 노후화 현상에 대한 현장 조사를 실시하였다. 조사대상 승강기는 1990년도부터 시설된 교류제어방식 승강기와 1995년부터 설치된 인버터 승강기이다. 현장 조사 결과 승강기의 주요 노후화 현상은 누유, 마모, 부식 등인 것으로 조사되었다. 또한 승강기가 시설되고 8년이 되는 시점부터 고장 횟수가 크게 증가하는 것으로 분석되었다.
-
본 연구에서는 광섬유형(Fiber Optic Current Sensor) 광전류센서 구성 시 발생하는 선형복굴절(Linear Birefringence)의 보상에 용이한 수직원형틀(Orthogonal Loop Type) 센서헤드(Sensor Heads)를 개선하여 1 Cross 수직원형틀(l Cross Orthogonal Loop Type)을 제시하였다. 그리고 기존의 페루프형 원형틀 (Closed Loop Type), 수직원형틀 그리고 1 Cross 수직원형틀의 편광상태를 비교하였다. 그 결과 편광상태 측정 시 페루프 원형틀을 수직원형틀로 교체할 경우 15.3%, 1 Cross 수직원형틀로 교체할 경우 33.8%의 선형복굴절 감소 효과가 나타났다. 이에 1 Cross 수직원형틀을 광전류센서에 적용할 경우 안정된 편광특성으로 고신뢰성 광전류센서 개발 가능성을 높게 할 것이다.
-
In this paper, the ozonizer is equipped with three electrodes ( two external electrodes, central electrode ), and AC high voltage which has 180[
$180^{circ}C$ ] phase difference is applied to two H V. Ozone discharge and generation charactristics have been investigated in accordance with output voltage of power supply, flow-rate, discharge power. Ozone concentration, generation and yield were proportionally increased with increasing discharge area size. -
This paper describes the discharge and ozone generation characteristics with variation of the applied voltage, the number of ozonizer, the quantity of flowing material gas. The important conclusions are as follows. The discharge voltage and current values are proportional to the applied voltage. The ozone concentration and generation are proportional to the applied voltage and the number of ozonizer. As the maximum value of ozone concentration and generation of silent discharge type ozonizer using discharge lamp can be obtained 890[ppm] and 59.7[mg/h] respectively.
-
This paper presents the thermal and electrical characteristics of ZnO arrester blocks under the AC voltages. The leakage currents of ZnO arrester blocks were measured as a function of time. The temperature distributions of ZnO arrester blocks were observed by the forward looking infrared camera The degradation and thermal runaway of ZnO arrester blocks were closely related with the temperature limit of ZnO arrester blocks which decided heat generation and dissipation As a result, the degradation and thermal runaway of ZnO arrester blocks depend on the temperature and leakage current of ZnO arrester blocks.
-
Transverse Linear Motor(TFLM) has been using in many areas of manufacture such as LCD, PDP construction and etc. However, the areas of TFLM application become wider, it needs a modification for new application. Above all, the conventional position estimation method is expensive in proportional to the length of the motor. Therefore, we need new position estimation algorithm using hall effect sensor.
-
In this paper we present development process and results of some cases for underground pad transformer and switchgear. Some characteristic factors was considered and tested to improve the functions of the case, such as natural convection of cooling air between the internal and external cases, properties of material that used as external panel etc. Proposed designs and functional characteristics will be adapted to making the cases of underground facilities after the elaborated tests. The results obtained from this study will improve the scenery of a street.
-
In this paper, the Time-varying Failure Rate (TFR) of power distribution system equipment is extracted from the recorded failure data of Korea Electric Power Corporation (KEPCO). For TFR extraction, it is used that the fault data accumulated by KEPCO during 10 years. The TFR is approximated to bathtub curve using the exponential (random failure) and Weibull (aging failure) distribution function. In addition, Kaplan-Meier estimation is applied to TFR extraction because of incomplete failure data of KEPCO. Finally, Probability plot and regression analysis is applied. It is presented that the extracted TFR is more effective and useful than Mean Failure Rate (MFR) through the comparison between TFR and MFR.
-
Battery type surgical handpiece is suitable for delicate surgical operating. The conventional air-type handpiece has a mechanical noise, a strong oscillation and a danger of infection. And the conventional contact switching type handpiece has problems that is restricted by surroundings. By reason of this kind, we studied noncontact switching type surgical handpiece to change conventional air type surgical handpiece and contact switching type.
-
As people's living standard is being improved, human works are being replaced by robots. However, because roost robots are used in process industry, fixed on the ground, we need to develop human robots that have wide applications. Currently many researches are being conducted on human robots with the object of replacing human works, but because of lack of relevant hardware, such robots are being applied limitedly to very simple tasks. To overcome the limitation, the present study developed a kinematical mechanism and a controller. Based on human kinematics, the shoulders and the arms were composed of master arms with 3 degree of freedom, and we reproduced motions similar to human ones through the characteristics of joint variables and experiment on the trajectory of the end effector.
-
In this paper, a new method for detecting rotor vibrations in a squirrel-cage induction motor is proposed. The air-gap flux variation analysis was done using search coils inserted in stator slots when rotor vibration conditions occurs. An accurate modelling and analysis of air-gap flux variation in the induction motor are developed using finite-element (FE) software packages, and treasuring the flux are made using search coils. In the FE analysis and experiment, the three-phase squirrel-gage induction motor with 380 [V], 7.5 [kW], 4 Poles, 1,768 [rpm] ratings is used. The simulation and experiment results can be useful for detecting rotor vibration of the induction motors.
-
Lee, Chang-Uk;Lee, Chang-Hun;Choi, Eun-Hyuck;Yoon, Dae-Hee;Jang, Seung-Ho;Kim, Jung-Bae;Park, Won-Zoo;Lee, Kwang-Sik 385
In this paper approves AC high voltage by experimental GIS(Gas Insulated Switchgear) chamber and AC 300[kV] power source to study breakdown characteristics by pressure(P) change and change of electrode distance(d) at AC high voltage of Imitation Air(I-Air,$N_2$ :$O_2$ = 79[%] : 21[%]) to alternate$SF_6$ and achieved research. Gave P change of I-Air to study I-Air's breakdown characteristics using non-uniform fields(Needle--Plane electrode) and studied relations breakdown voltage ($V_B$ ) by each P different d. -
Thermoelement cooling special Quality analysis for DMFC high effectiveness electric power occurrence본 연구는 지벡(Seebeck)효과를 이용한 열전발전소자의 효율증가를 위한 Cooling System에 대한 연구이다. 열전발전소자는 Hot side와 Cool side의 온도차에 의해 전력발생 효율이 결정되며 열전발전소자가 견딜 수 있는 Hot Side의 온도는 고정돼있는 반면, Cool Side의 온도는 Cooling System의 설계에 따라 온도 설정이 가능하다. 본 연구는 Cooling System은 방열판과 팬으로 구성된 공랭방식을 사용하였고, 냉각효율을 높이기 위해 방열판의 크기 및 모양 팬의 크기와 속도 공기의 이동방향에 따른 냉각특성을 실험하였고 그에 따른 특성들을 논하고자 한다.
-
Construction form and status analysis of intelligent type switching board of educational institutionRecently one level higher intelligent switching board than established one by the application of intelligent building and digital system are being constructed. Therefore facility's high efficiency, high degree satisfaction, miniaturaization, standardization through application of communication technology and monitoring and controlling by computer system utilized by web-basis power control system and electric IT are practiced. Especially network must be constructed through unified IBS server that monitors every educational institute's switching boards in real time control system. And I intend to create methods to save energy and raise electricity quality by power demand prediction and remote-controled management and operation. In this thesis I intend to suggest measures of forming unified system through researching educational institute's ways of constructing switching board and status analysis and overcoming technical difficulties in user's side and saving and maintenance expense.
-
This paper presents multiple regression analysis and data update to improve present spatial electric load forecasting algorithm of the DISPLAN. Spatial electric load forecasting considers a local economy, the number of local population and load characteristics. A Case study is performed for Jeon-Ju and analyzes a trend of the spatial load for the future 20 years. The forecasted information can contribute to an asset management of distribution systems.
-
This research describes how the class D amplifiers with power efficiency are designed and implemented for the PA audio systems. The configuration that makes use of the class D amplifier properties depends strongly on their applications. Thus in this paper the characteristics of the 2-level and 3-level PWM are analysed and the circuit implementation for them is presented. Using the proposed methods, they are designed and simulated for the further investigation. Test(Simulation) results present the improved performance that shows the satisfactory operations in controlling the PWM to the input signals.
-
정거장 구내에서는 본선으로부터 측선으로 진로를 바꾸는 등 하나의 선로에서 다른 선로로 분기하기 위하여 분기지점에 설치한 궤도 설비를 분기기라 하며 분기기의 방향을 전환시키는 것을 선로전환기라 하는데 이 장치에 문제가 발생 시 심각한 상황이 초래할 수 있다. 이 장치에는 정밀한 기기와 센서가 설치되어 사용되는데 중요한 설비 임에도 장애가 많이 발생하며 이로 인한 열차 탈선이라는 극한의 상황까지 이를 수 있다. 본 논문에서는 사용 중인 안전장치들을 장애와 사고를 정밀 분석하고 이를 대체할 수 있는 장치를 개발하여 시험설치 하였다. 이 장치는 이상전압 및 낙뢰의 영향을 받지 않도록 설계되어서 열차 운전이 원활하게 된다.
-
Kim, Do-Seok;Kim, Young-Su;Lee, Sang-Ho;Do, Young-Hoe;Park, Kwang-Seo;Kim, Lee-Kook;Lee, Kwang-Sik 410
본 연구는 제조공기(I-Air)의 온도(T)의 변화(+10[$^{\circ}C$ ]$^{\sim}$ -30[$^{\circ}C$ ])에 따른 절연특성을 구명하였다. 절연특성은 GIS모의 챔버 주입 압력 (P)과 비례하는 특성을 보였으나 T가 저하되면서 그 절연특성이 감소하는 경향을 보이지 않고 오히려 증가하는 구간이 존재 하였다. 그리고 챔버내 P의 크기가 클수록 T저하에 대한 P감소율이 더 컸으나, 절연파괴전압($V_B$ )감소폭은 이와는 달리 4[atm]에서 가장 큰 변화를 보였다. -
If obstacle in GIS(Gas Insulted Switchgear), its affects are great are on the community and it is consequently demanded lots of difficulities to recover and repair. Accordingly, diagnosis techniques, that are able to prevent from accidents before they happen by providing more stable and highly reliable power effectively and finding sign of the accidents is very important. The strip-senser measured impedance bandwidth of the proposed antenna is from 0.5[GHz] to 2.5[GHz] with the stop band from 0.5[GHz] to 1.7[GHz] for VSWR<2. The antenna is will play an important role for the senser for insulation diagnosis system by UHF method of real site GIS and power equipment using
$SF_6$ gas. -
1997년 교토 기후협약이 체결되었고, 우리나라도 2013 년부터 기후협약 규제가 거의 확실시 되고 있다. 화석 연료의 연소로 대부분의 전력 을 생산하는 발전 산업은 우리나라 CO2 배출량의 25%를 차지하고 있으며, 발전소의 전력 생산에 따른 CO2배출량의 계산은 매우 중요한 일이 되었다. 본 논문은 발전소의 시험data 와 IPCC (Intergovernmental Panel on Climate Change)의 온실가스 추계방법론을 이용하여 시간당 CO2 대기 배출량을 계산하는 방법을 제시한다. 발전출력에 대한 CO2 배출량을 계산하는 한 예를 도시하였다.
-
The paper used to the Neral Netwok for a forecasting conservation system A neural network is a powerful data modeling tool that is able to capture and represent complex input/output relationships. The motivation for the development of neural network technology stemmed from the desire to develop an artificial system that could perform "intelligent" tasks similar to those performed by the human brain. The true power and advantage of neural network lies in their ability to represent both linear and non-linear relationships and in their ability to learn these relationships directly from the data being modeled. Form results of this study, the Neral Netwok is will play an important role for insulation diagnosis system of real site GIS and power equipment using
$SF_6$ gas. -
본 연구에서는 UHF 대역의 측정이 가능한 Cavity 안테나를 이용하여 절연진단기술에서의 적용가능성을 검토해 보았다. 제안된 안테나는 유전체 손실이나 급전라인의 손실이 없는 공기를 매질로 하므로, 고출력에 적합하며 고효율을 가진다. 또한 제작이 용이한 구조를 가지므로 대량 생산 시 많은 장점올 가질 것으로 기대된다. 시뮬레이션을 통하여 Cavity 안테나가 0.3
${\sim}$ 10[GHz] 대역에서는 -10[dB]이하의 Return loss값을 가지는 측정주파수 대역이 약 2.7${\sim}$ 10[GHz]로 나타났으며, 0.3${\sim}$ 2.5[GHz]의 대역일 경우는 측정 주파수 대역이 약 0.7${\sim}$ 2.5[GHz]으로 나타남으로써 대표적인 전력기기인 GIS(Gas Insulated Switchgear : 가스절연개폐장치)에서 UHF 대역을 이용한 절연진단기술에서 사용하는 주파수 대역에서 사용이 가능함을 확인할 수 있었다. -
This paper research data and information for market environment of electric power value added service According to research, in USA using power line communication(PLC) and other communication device(ex ZigBee, Wireless and so on) online observation and building district management service were being realized Also, in Japan they are executing online electricity facility Igr monitoring service based on IT basic for checking insulation. Also we conduct a survey of H-SCP concept and demand for electric power value added service of Housewife and Working women. This paper will be used data for revitalizing market circumstance of electric power value added service.
-
This paper analyzes how to calculate the three phase short-circuit currents for ac electrical system and select the high & low voltage circuit breaker based on IEC60609, IEC60056 and IEC60947-2 standards. We proposed the multiplying factor considering system time constant and circuit breaker rating to select circuit breaker accurately.
-
This paper was analyzed the resistivity change characteristic of mortar model block and concrete that was made earth electrode that's used concrete or basic concrete of building for 1 year. The early resistivity measurement value of concrete model block is higher than mortar model block. But after 1 year the resistivity measurement value of mortar model block is significantly higher than concrete model block. Because depends on time elapsed complete dryness factor of mortar model block that has not gravel is higher than concrete model block. And absorptance and function of mortar mode block was by far outstanding than concrete model block in the data for verification of the amount of contained water and the amount of dryness of mortar model block and concrete model block.
-
This paper deals with assessment of risk component for electrical safety and investigation on the spot of computer room in elementary middle high school. The investigation was carried out side by side for floor, outlet, panel board, earth leakage circuit breaker at computer room In order to assess electrical safety at computer room, grounding simulator and power quality monitor have been used. Potential rise has been measured and analyzed for ground rod and grounding grid by using the simulator. Phase and neutral-line current have been monitored in real time. As a consequence, it is desirable for us to install conductive tile at floor of computer room Grounding grid had better than ground rod for electrical safety. Neutral-line current was produced by unbalanced phase current.
-
본 논문에서는 국, 내외 피뢰설비 규정을 고찰하고 ESE 피뢰침의 평가기준이 무엇인지 반문하였으며 우리 나라에 적 합한 피뢰 규정으로 KS C IEC - 61024(한국산업 표준규격)와 NF C 17-102(프랑스 산업표준규격)의 혼합형인 이중보호방식을 제시하였다.
-
전력사용이 증가함에 따라 전기설비에 의한 전기화재 수가 늘어나고 있다. 통계에 따르면 전기화재가 화재원인 중 가장 많은 비중을 차지하고 있음을 알 수 있다. 그럼에도 불구하고 전기화재를 정확히 찾아낼 수 있는 조사기법이 개발되지 않고 있는 실정이다. 이 논문은 전기화재 원인과 아크차단기의 특성에 관하여 분석한다. 아크에 의한 위험을 수학적 분석을 이용한 전력계산을 통하여 분석하고 단락회로에 의한 위험성과 비교한다. 또한 아크차단기와 기존의 누전차단기와 비교를 통하여 아크차단기의 필요성을 제기한다.
-
An, Hae-Joon;Ro, Kyoung-Soo 454
This study suggests a modeling of grid-connected wind turbine generation system that has induction generator, and aims to perform simulations for outputs by the variation of actual wind speed and for fault current of wind generation system by the transformer winding connection. This study is implemented by MARTLB & SIMULINK. The simulation shall be performed by assuming single line to ground fault generated in the system Generator power, rotor speed, terminal voltage, system voltage, and fault current shall be observed following the performance of simulation. The fault current change will be dealt through the simulation results for fault current of wind generation system following the grid-connected transformer winding connection and the simulation result by the transformer neutral ground method. -
It is necessary to study a conductive characteristics of electrical facilities covered with particulate for the analysis of electrical accidents in vulnerable area where are included market place, a sawmill and so on. Therefore, there are studied on risk assessment and contact angle measure(CAM) according to surface deterioration of PVC and phenolic resin Through the contact angle measure of samples, there are ascertain whether hydrophobicity or not. These data would used to be judged by the causes of electrical accidents.
-
It is necessary to study the prevention and the management of electrical facilities because the electrical fault took place at the dust occurrence area due to environmental pollution. In particular, the dust accumulates easily on insulation material which is exposed an external long time. The leakage current brings out electrical fault after all. Also, it is need to variation of material and shape to repress a leakage current on electrical material. In this paper, we measured a leakage current on electrical material of facilities by dust, and in experiments the prevention to electrical fault was studied.
-
For small capacity rectifier circuits such as these for consumer electronics and appliances, capacitor input type rectifier circuits are generally used. Consequently, various harmonics generated within the power system become a serious problem. Various studies of this effect have been presented previously. The absence of switching devices makes systems more tolerant to over-load, and brings low radio noise benefits. We propose a power factor correction scheme using a LC resonant in commercial frequency without switching devices. In this method, It makes a sinusoidal wave by widening conduction period using the current resonance in commercial frequency, Hence, the harmonic characteristics can be significantly improved, where the lower order harmonics, such as the fifth and seventh orders are much reduced. The result are confirmed by the theoretical and expermental implementations
-
The development of advanced Insulated Gate Bipolar Transistor(IGBT)has enabled high-frequency switching operation and has improved the performance of PWM inverters for motor drive. However, the high rate of dv/dt of IGBT has adverse effects on motor insulation stress. In many motor drive applications, the inverter and motor are separated and it requires long motor feds. The long cable contributes high frequency ringing at the motor terminal and it results in hight surge voltage which stresses the motor insulation. The inverter output filter and RDC snubber are conventional method which can reduce the surge voltage. In this paper, we propose the new low loss snubber to reduce the motor terminal surge voltage. The snubber consists of the series connection of charging/discharging capacitor and the voltage-clamped capacitor. At IGBT turn-off, the snubber starts to operate when the IGBT voltage reaches the voltage-clamped level. Since dv/dt is decreased by snubber operating, the peak level of the surge voltage can be reduced. Also the snubber operates at the IGBT voltage above the voltage-clamped level, the snubber loss is largely reduced comparing with RDC snubber. The proposed snubber enables to reduce the motor terminal surge voltage with low loss.