한국원자력학회:학술대회논문집 (Proceedings of the Korean Nuclear Society Conference) (Proceedings of the Korean Nuclear Society Conference)
한국원자력학회 (Korean Nuclear Society)
- 반년간
한국원자력학회 1999년도 춘계학술발표회요약집
-
-
-
-
-
-
-
The HELlOS-MASTER code system is verified through the benchmark of the critical experiments that were performed by RRC "Kurchatov Institute" with water-moderated hexagonally pitched lattices of highly enriched Uranium fuel rods (8Ow/o). We also used the same input by using the MCNP code that was described in the evaluation report, and compared our results with those of the evaluation report. HELlOS, developed by Scandpower A/S, is a two-dimensional transport program for the generation of group cross-sections, and MASTER, developed by KAERI, is a three-dimensional nuclear design and analysis code based on the two-group diffusion theory. It solves neutronics model with the AFEN (Analytic Function Expansion Nodal) method for hexagonal geometry. The results show that the HELIOSMASTER code system is fast and accurate enough to be used as nuclear core analysis tool for hexagonal geometry.ometry.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
The local heat transfer coefficient is experimentally investigated for the reflux condensation in a countercurrent flow between the steam-air mixture and the condensate. A single vertical tube has a geometry which is a length of 2.4m, inner diameter of 16.56mm and outer diameter of 19.05mm and is made of stainless steel. Air is used as a noncondensible gas. The secondary side is installed in the form of coolant block around vertical tube and the heat by primary condensation is transferred to the coolant water. The local temperatures are measured at 15 locations in the vertical direction and each location has 3 measurement points in the radial direction, which are installed at the tube center, at the outer wall and at the coolant side. In three different pressures, the 27 sets of data are obtained in the range of inlet steam flow rate 1.348 -3.282kg/hr, of inlet air mass fraction 11.8 -55.0%. The local heat transfer coefficient increases as the increase of inlet steam flow rate and decreases as the decrease of inlet air mass fraction. As an increase of the system pressure, the active condensing region is contracted and the heat transfer capability in this region is magnified. The empirical correlation is developed represented with the 165 sets of local heat transfer data. As a result, the Jacob number and film Reynolds number are dominant parameters to govern the local heat transfer coefficient. The rms error is 17. 7% between the results by the experiment and by the correlation.
-
-
Direct-contact condensation experiments of atmospheric steam and steam/air mixture on subcooled water flowing co-currently in a rectangular channel are carried out uszng an infrared thermal camera system to develop a temperature measurement method. The inframetrics Model 760 Infrared Thermal Imaging Radiometer is used for the measurement of the temperature field of the water film for various flow conditions. The local heat transfer coefficient is calculated using the bulk temperature gradient along the (low direction. It is also found that the temperature profiles can be used to understand the interfacial condensation heat transfer characteristics according to the flow conditions such as noncondensable gas effects, inclination effect, and flow rates.
-
-
The standard RELAP5/MOD3.2 code was modified using the non-iterative modeling. which is developed to simulate steam condensation in the presence of noncondensable gases ill a vertical tube. The modified RELAP5/MOD3.2 code was used to simulate two kinds of vertical in-tube experiments involving the condensation phenomenon in the presence of noncondensable gases. The modeling capabilities of the modified RELAP5/MOD3.2 codc as well as the standard code for the condensation in the presence of noncondensable gases are assessed using two PCCS condensation experiments and four reflux condensation experimcnts. The modified RELAP5/MOD3.2 code gives good prediction over the data of both PCCS condensation and reflux condensation experiments
-
-
To demonstrate the applicability of RELAP5 to the prediction of the onset offlooding in the hot leg at the reflux condensation phase during mid-loop operation, numerical analysis is performed for the counter-current flow in a horizontal pipe with the inclined riser using the RELAP5/MOD3.2.2b code. It is found that the RELAP5, simulating the CCFL phenomena using interfacial friction along with the flow regime map in the horizontal pipe, produces unsatisfactory results. Under the CCFL condition, it is observed that large oscillation exists in the flow rate, void fraction, and etc. and the liquid flow rate is much lower than that predicted by the CCFL model measured in the experiment. The CCFL model of RELAP5 for the vertical volume is extended to the model for the horizontal and inclined volumes. The horizontal volume flow regime map and interfacial friction model coupled to the CCFL model are modified. And a new correlation developed from Kang's experiment is implemented to the CCFL model of RELAP5. With this modified RELAP5, the analysis of CCFL phenomena in the horizontal pipe and hot leg geometry is performed, and produces reasonable results in comparison with experimental data.
-
-
-
An ultrasonic method is developed for the measurement of the two-phase mixture level in the reactor vessel or steam generator. The ultrasonic method is selected among the several non¬nuelear two-phase mixture level measurement methods through two steps of selection procedure. A commercial ultrasonic level measurement method is modified for application into the high temperature, pressure, and other conditions. The calculation method of the ultrasonic velocity is modified to consider the medium as the homogeneous mixture of air and steam. and to be applied into the high temperature and pressure conditions. The cross-correlation technique is adopted as a detection method to reduce the effects of the attenuation and the dif.JUsed reflection caused by suface fluctuation. The waveguides are developed to reduce the loss of echo and to remove the effects of obstructs. The present experimental study shows that the developed ultrasonic method measures the two-phase mixture level more accurately than the conventional methods do.
-
-
-
-
-
-
-
-
-
Pool boiling critical heat flux (CHF) have been investigated using plate type test sections with different widths (3 cm & 4 cm) and lengths (10 cm, IS cm & 20 cm) under various incli- nation angles. As the inclination angle increases from
$0^{\circ}$ (horizontally facing downward plate) to$30^{\circ}$ , CHF sharply increases. After that angle, CHF gradually increases with the increase of the inclination angle. There must be a transition angle between$0^{\circ}$ and$30^{\circ}$ , at which the CHF increase rate remarkably changes. According to the comparison of present and previous ex- periments, the transition angle may be affected by heater size and increase with the increase of heater size. The size effect of heated surface on CHF is noticeable in the L15 & L20 series and W4 series; however, it seems to be difficult to find the size effect in L10 series and W3 series. -
-
Application of the macro layer dryout model has been performed to predict CHF at inclined plates. For the identification of the detachment frequency of coalesced bubble, experiments have been performed with high-speed motion analyzer and bubble behaviors at inclined plates have been investigated. Based on the observed bubble behaviors, the detachment frequency of the coalesced bubble is measured and linear relations between detachment frequency and heat flux have been developed. In the case of 60
$^{\circ}$ and 90$^{\circ}$ inclined plate, the detachment frequency decreases with the increase of heat flux. However, opposite trend has been identified in$30^{\circ}$ in-clined plate: the detachment frequency increases with the increase of heat flux. Using the cor- relation of macro layer thickness suggested by Haramura & Katto and the extrapolation of the identified linear relations, CHFs at different conditions have been predicted. According to the prediction results, CHF values are well predictable. -
-
-
-
-
-
-
-
-
-
-
-
-
Kim, Eun-Ka;Chun, Yong-Bum;You, Gil-Sung;Min, Duck-Kee;Kim, Yong-Soo;Kim, Kyoung-Doek;Shin, Sang-Woon;Lee, Myung-Chan 220
-
-
-
Park, Jong-Man;Kim, Ki-Hwan;Park, Soo-Bong;Lee, Don-Bae;Lee, Yun-Sang;Lee, Jeong-Soo;Kim, Chang-Kyu 257
-
-
-
-
-
To improve the corrosion model of the fuel performance analysis code COSMOS, a model was developed considering thermohydraulic phenomena and the effect of water chemistry and low Sn in the alloy composition on the corrosion behavior. It is assumed that the lithium enhancement factor influences the corrosion behavior only if the subcooled void is present in the coolant. The developed model was verified with the database obtained from Grohnde and Ringhals 3 reactors. Comparison of predicted oxide thickness with measured data showed the applicability of COSMOS code to analyze the cladding oxidation. In the future, the effect of the hydride in the cladding and the precipitate changes due to irradiation should be included.cluded.
-
-
-
-
-
-
-
Lee, Myung-Ho;Shin, Hyun-Sang;Kim, Mi-Kyung;Park, Gun-Sik;Hong, Kwang-Hee;Cho, Yung-Hyun;Lee, Chang-Woo 353
-
Shin, Hyun-Sang;Lee, Chang-Woo;Myung-Ho lee;Kim, Mee-Kyung;Park, Kun-Sick;Park, Yung-Hyun;Hong, Kwang-Hee 354
-
-
-
-
Park, Joon-Young;Lee, Kyung-Han;Shim, Young-Mog;Lee, Kyung-Soo;Kim, Jae-Jun;Kim, Sang-Eun;Kim, Byung-Tae 384
-
-
-
-
-